    Absolute radiometric calibration of the EUNIS-06 170-205 A channel and calibration update for CDS/NIS

    Full text link
    The Extreme-Ultraviolet Normal-Incidence Spectrograph sounding-rocket payload was flown on 2006 April 12 (EUNIS-06), carrying two independent imaging spectrographs covering wave bands of 300-370 A in first order and 170-205 A in second order, respectively. The absolute radiometric response of the EUNIS-06 long-wavelength (LW) channel was directly measured in the same facility used to calibrate CDS prior to the SOHO launch. Because the absolute calibration of the short-wavelength (SW) channel could not be obtained from the same lab configuration, we here present a technique to derive it using a combination of solar LW spectra and density- and temperature-insensitive line intensity ratios. The first step in this procedure is to use the coordinated, cospatial EUNIS and SOHO/CDS spectra to carry out an intensity calibration update for the CDS NIS-1 waveband, which shows that its efficiency has decreased by a factor about 1.7 compared to that of the previously implemented calibration. Then, theoretical insensitive line ratios obtained from CHIANTI allow us to determine absolute intensities of emission lines within the EUNIS SW bandpass from those of cospatial CDS/NIS-1 spectra after the EUNIS LW calibration correction. A total of 12 ratios derived from intensities of 5 CDS and 12 SW emission lines from Fe Fe X - Fe XIII yield an instrumental response curve for the EUNIS-06 SW channel that matches well to a relative calibration which relied on combining measurements of individual optical components. Taking into account all potential sources of error, we estimate that the EUNIS-06 SW absolute calibration is accurate to about 20%.Comment: 11 pages, 10 figures, 4 tables. 2010, ApJ Suppl. In pres

    Linfield Student Cookbook

    Get PDF
    The Linfield Student Health, Wellness and Counseling Center has been working to meet students\u27 nutritional needs by creating a student cookbook, suitable for use in limited kitchen space. We have become aware that Linfield students are interested in nutrition and wellness but may not have a full kitchen or budget to work with. By creating and distributing this cookbook, we hope that students will be able to utilize it as a resource to learn more about healthy eating and put this knowledge into practice, working toward the ultimate goal of lifelong wellness

    Different Patterns of Chromospheric Evaporation in a Flaring Region Observed with Hinode/EIS

    Full text link
    We investigate the chromospheric evaporation in the flare of 2007 January 16 using line profiles observed by the EUV Imaging Spectrometer (EIS) onboard Hinode. Three points at flare ribbons of different magnetic polarities are analyzed in detail. We find that the three points show different patterns of upflows and downflows in the impulsive phase of the flare. The spectral lines at the first point are mostly blue shifted, with the hotter lines showing a dominant blue-shifted component over the stationary one. At the second point, however, only weak upflows are detected; in stead, notable downflows appear at high temperatures (up to 2.5-5.0 MK). The third point is similar to the second one only that it shows evidence of multi-component downflows. While the evaporated plasma falling back down as warm rain is a possible cause of the redshifts at points 2 and 3, the different patterns of chromospheric evaporation at the three points imply existence of different heating mechanisms in the flaring active region.Comment: 18 pages, 7 figures, 2 tables. Accepted for publication in Ap

    Underflight calibration of SOHO/CDS and Hinode/EIS with EUNIS-07

    Full text link
    Flights of Goddard Space Flight Center's Extreme-Ultraviolet Normal-Incidence Spectrograph (EUNIS) sounding rocket in 2006 and 2007 provided updated radiometric calibrations for SOHO/CDS and Hinode/EIS. EUNIS carried two independent imaging spectrographs covering wavebands of 300-370 A in first order and 170-205 A in second order. After each flight, end-to-end radiometric calibrations of the rocket payload were carried out in the same facility used for pre-launch calibrations of CDS and EIS. During the 2007 flight, EUNIS, SOHO CDS and Hinode EIS observed the same solar locations, allowing the EUNIS calibrations to be directly applied to both CDS and EIS. The measured CDS NIS 1 line intensities calibrated with the standard (version 4) responsivities with the standard long-term corrections are found to be too low by a factor of 1.5 due to the decrease in responsivity. The EIS calibration update is performed in two ways. One is using the direct calibration transfer of the calibrated EUNIS-07 short wavelength (SW) channel. The other is using the insensitive line pairs, in which one member was observed by EUNIS-07 long wavelength (LW) channel and the other by EIS in either LW or SW waveband. Measurements from both methods are in good agreement, and confirm (within the measurement uncertainties) the EIS responsivity measured directly before the instrument's launch. The measurements also suggest that the EIS responsivity decreased by a factor of about 1.2 after the first year of operation. The shape of the EIS SW response curve obtained by EUNIS-07 is consistent with the one measured in laboratory prior to launch. The absolute value of the quiet-Sun He II 304 A intensity measured by EUNIS-07 is consistent with the radiance measured by CDS NIS in quiet regions near the disk center and the solar minimum irradiance obtained by CDS NIS and SDO/EVE recently.Comment: 16 pages, 14 figures, 5 tables, accepted by ApJ Supplement (Sep. 2011

    The problem of causality in cultivation research

    Get PDF
    This paper offers an up-to-date review of problems in determining causal relationships in cultivation research, and considers the research rationales of various approaches with special reference to causal interpretation. It describes in turn a number of methodologies for addressing the problem and resolving it as far as this is possible. The issue of causal inference arises not only in cultivation research, however, but is basic to all media effects theories and approaches primarily at the macro-level whose main methodology rests on correlational studies (agenda-setting, spiral of silence, knowledge gap hypothesis, etc.). We therefore first discuss problems of causal interpretation in connection with the cultivation hypothesis, and then sketch in summary how these problems arise with other media effects theories. We first set out the basic features of the cultivation approach, then consider the difficulties with correlational studies and discuss alternative research designs - designs which are not original to us, but have been adapted for cultivation research. These comprise laboratory experiments, sequential studies, social studies and time-series procedures. Finally, we argue for multiple approaches that complement one another's advantages and balance out their disadvantages

    Evidence of Explosive Evaporation in a Microflare Observed by Hinode/EIS

    Full text link
    We present a detailed study of explosive chromospheric evaporation during a microflare which occurred on 2007 December 7 as observed with the EUV Imaging Spectrometer (EIS) onboard Hinode. We find temperature-dependent upflows for lines formed from 1.0 to 2.5 MK and downflows for lines formed from 0.05 to 0.63 MK in the impulsive phase of the flare. Both the line intensity and the nonthermal line width appear enhanced in most of the lines and are temporally correlated with the time when significant evaporation was observed. Our results are consistent with the numerical simulations of flare models, which take into account a strong nonthermal electron beam in producing the explosive chromospheric evaporation. The explosive evaporation observed in this microflare implies that the same dynamic processes may exist in events with very different magnitudes.Comment: 14 pages, 8 figures. Accepted for publication in the Astrophysical Journa

    Theoretical models of free-free microwave emission from solar magnetic loops

    Get PDF
    The free-free microwave emission is calculated from a series of model magnetic loops. The loops are surrounded by a cooler external plasma, as required by recent simultaneous X ray and microwave observations, and a narrow transition zone separating the loops from the external plasma. To be consistent with the observational results, upper limits on the density and temperature scale lengths in the transition zone are found to be 360 km and 250 km, respectively. The models which best produce agreement with X ray and microwave observations also yielded emission measure curves which agree well with observational emission measure curves for solar active regions

    Emission lines of Fe XI in the 257--407 A wavelength region observed in solar spectra from EIS/Hinode and SERTS

    Full text link
    Theoretical emission-line ratios involving Fe XI transitions in the 257-407 A wavelength range are derived using fully relativistic calculations of radiative rates and electron impact excitation cross sections. These are subsequently compared with both long wavelength channel Extreme-Ultraviolet Imaging Spectrometer (EIS) spectra from the Hinode satellite (covering 245-291 A), and first-order observations (235-449 A) obtained by the Solar Extreme-ultraviolet Research Telescope and Spectrograph (SERTS). The 266.39, 266.60 and 276.36 A lines of Fe XI are detected in two EIS spectra, confirming earlier identifications of these features, and 276.36 A is found to provide an electron density diagnostic when ratioed against the 257.55 A transition. Agreement between theory and observation is found to be generally good for the SERTS data sets, with discrepancies normally being due to known line blends, while the 257.55 A feature is detected for the first time in SERTS spectra. The most useful Fe XI electron density diagnostic is found to be the 308.54/352.67 intensity ratio, which varies by a factor of 8.4 between N_e = 10^8 and 10^11 cm^-3, while showing little temperature sensitivity. However, the 349.04/352.67 ratio potentially provides a superior diagnostic, as it involves lines which are closer in wavelength, and varies by a factor of 14.7 between N_e = 10^8 and 10^11 cm^-3. Unfortunately, the 349.04 A line is relatively weak, and also blended with the second-order Fe X 174.52 A feature, unless the first-order instrument response is enhanced.Comment: 9 pages, 5 figures, 13 tables; MNRAS in pres
    corecore