511 research outputs found

    Phase dynamics of InAs/GaAs quantum dot semiconductor optical amplifiers

    Get PDF
    The gain and phase dynamics of InAs/GaAs quantum dot amplifiers are studied using single and two-color heterodyne pump probe spectroscopy. The relaxation of the wetting layer carrier density is shown to have a strong effect on the phase dynamics of both ground and excited state transients, while having a much weaker effect on the gain dynamics. In addition, the dynamical alpha factor may also display a constant value after an initial transient. Such behavior is strongly encouraging for reduced pattern effect operation in high speed optical networks. (c) 2007 American Institute of Physics.(DOI: 10.1063/1.2823589

    Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography

    Get PDF
    ObjectivesCumulative radiation dose, cost, and increased demand for computed tomography aortography (CTA) suggest that duplex ultrasonography (DU) may be an alternative to CTA-based surveillance. We compared CTA with DU during endovascular aneurysm repair (EVAR) follow-up.MethodsPatients undergoing EVAR had clinical and radiological follow-up data entered in a prospectively maintained database. For the purpose of this study, the gold standard test for endoleak detection was CTA, and an endoleak detected on DU alone was assumed to be a false positive result. DU interpretation was performed independently of CTA and vice versa.ResultsOne hundred thirty-two patients underwent EVAR, of whom 117 attended for follow-up ranging from six months to nine years (mean, 32 months). Adequate aneurysm sac visualisation on DU was not possible in 1.7% of patients, predominantly due to obesity. Twenty-eight endoleaks were detected in 28 patients during follow-up. Of these, 24 were initially identified on DU (four false negative DU examinations), and eight had at least one negative CTA with a positive DU prior to diagnosis. Twenty-three endoleaks were type II in nature and three of these patients had increased sac size. There was one type I and four type III endoleaks. Two of these (both type III) had an increased sac size. Of 12 patients with increased aneurysm size of 5 mm or more at follow-up, five had an endoleak visible on DU, yet negative CTA and a further five had endoleak visualisation on both DU and CTA. Of six endoleaks which underwent re-intervention, all were initially picked up on DU. One of these endoleaks was never demonstrated on CTA and a further two had at least one negative CTA prior to endoleak confirmation. Positive predictive value for DU was 45% and negative predictive value 94%. Specificity of DU for endoleak detection was 67% when compared with CTA, because of the large number of false positive DU results. Sensitivity for DU was 86%, with all clinically significant endoleaks demonstrated on CTA also detected on DU.ConclusionDespite its low positive predictive value, we found DU to be a sensitive test for the detection of clinically significant endoleaks. Given concerns about cumulative radiation exposure and cost, and the surprisingly low sensitivity of CTA for endoleak detection in this series, selective CTA based on DU surveillance may be a more appropriate long-term strategy

    Comparison of frequency symmetric signal generation from a BPSK input using fiber and semiconductor-based nonlinear elements

    Get PDF
    This letter compares two nonlinear media for simultaneous carrier recovery and generation of frequency symmetric signals from a 42.7-Gb/s nonreturn-to-zero binary phase-shift-keyed input by exploiting four-wave mixing in a semiconductor optical amplifier and a highly nonlinear optical fiber for use in a phase-sensitive amplifier

    Outbreak of Marburg hemorrhagic fever among miners in Kamwenge and Ibanda Districts, Uganda, 2007

    Get PDF
    Marburg hemorrhagic fever was detected among 4 miners in Ibanda District, Uganda, from June through September, 2007. Infection was likely acquired through exposure to bats or bat secretions in a mine in Kamwenge District, Uganda, and possibly human-to-human transmission between some patients. We describe the epidemiologic investigation and the health education response

    The effect of Gonioscopy on keratometry and corneal surface topography

    Get PDF
    BACKGROUND: Biometric procedures such as keratometry performed shortly after contact procedures like gonioscopy and applanation tonometry could affect the validity of the measurement. This study was conducted to understand the short-term effect of gonioscopy on corneal curvature measurements and surface topography based Simulated Keratometry and whether this would alter the power of an intraocular lens implant calculated using post-gonioscopy measurements. We further compared the effect of the 2-mirror (Goldmann) and the 4-mirror (Sussman) Gonioscopes. METHODS: A prospective clinic-based self-controlled comparative study. 198 eyes of 99 patients, above 50 years of age, were studied. Exclusion criteria included documented dry eye, history of ocular surgery or trauma, diabetes mellitus and connective tissue disorders. Auto-Keratometry and corneal topography measurements were obtained at baseline and at three follow-up times – within the first 5 minutes, between the 10(th)-15(th )minute and between the 20(th)-25(th )minute after intervention. One eye was randomized for intervention with the 2-mirror gonioscope and the other underwent the 4-mirror after baseline measurements. t-tests were used to examine differences between interventions and between the measurement methods. The sample size was calculated using an estimate of clinically significant lens implant power changes based on the SRK-II formula. RESULTS: Clinically and statistically significant steepening was observed in the first 5 minutes and in the 10–15 minute interval using topography-based Sim K. These changes were not present with the Auto-Keratometer measurements. Although changes from baseline were noted between 20 and 25 minutes topographically, these were not clinically or statistically significant. There was no significant difference between the two types of gonioscopes. There was greater variability in the changes from baseline using the topography-based Sim K readings. CONCLUSION: Reversible steepening of the central corneal surface is produced by the act of gonioscopy as measured by Sim K, whereas no significant differences were present with Auto-K measurements. The type of Gonioscope used does not appear to influence these results. If topographically derived Sim K is used to calculate the power of the intraocular lens implant, we recommend waiting a minimum of 20 minutes before measuring the corneal curvature after gonioscopy with either Goldmann or Sussman contact lenses

    The effects of add-on corticosteroids on renal outcomes in patients with biopsy proven HIV associated nephropathy: a single centre study from South Africa

    Get PDF
    Background The aim of this study was to assess, the efficacy and safety of add-on corticosteroids to antiretroviral therapy [ART] in patients with biopsy proven HIV associated nephropathy. Methods All included patients had histological evidence of either collapsing or non-collapsing focal segmental glomerulosclerosis (FSGS) or podocyte and/or parietal cell hypertrophy or hyperplasia. All patients had evidence of tubulointerstitial inflammation with microcysts. Patients were randomized to ART with the addition of 1 mg/kg of corticosteroids [ART+C] or remained in the group [ART Alone] and followed for 2 years. A repeat biopsy was performed at 6 months. Results Twenty-one patients were randomized to [ART+C] and 17 to [ART Alone]. The baseline estimated glomerular filtration rate (eGFR) was significantly lower in the [ART+C] vs. [ART Alone] group [35mls/min/1.73m2 vs. 47 mls/min/1.73m2, p = 0.015]. The [ART+C] cohort had a statistically significant improvement in median (eGFR) from baseline to last follow up compared with [ART Alone] i.e. [Δ = 25mls/min (IQR: 15;51) vs 9 mls/min (IQR: 0–24), p = 0.008]. There were no statistically significant differences between the groups when proteinuria and histology were analyzed. There were 8 deaths during the trial period, 7 from [ART+C] (Log rank p = 0.071). Conclusions In the [ART+C] cohort there was a significant improvement in eGFR over 2-years with increased mortality. Routine corticosteroid use cannot currently be recommended. Further investigation to define which subgroup of this cohort would safely benefit from the positive effects is required. Trial registration ISRCTN study ID ( 56112439 ] was retrospectively registered on the 5 September 2018
    • …
    corecore