37 research outputs found

    Plasma ramps caused by outflow in gas-filled capillaries

    Full text link
    Plasma confinement inside capillaries has been developed in the past years for plasma-based acceleration to ensure a stable and repeatable plasma density distribution during the interaction with either particles or laser beams. In particular, gas-filled capillaries allow a stable and almost predictable plasma distribution along the interaction with the particles. However, the plasma ejected through the ends of the capillary interacts with the beam before the inner plasma, affecting the quality of the beam. In this article we report the measurements on the evolution of the plasma flow at the two ends of a 1 cm long, 1 mm diameter capillary filled with hydrogen. In particular, we measured the longitudinal density distribution and the expansion velocity of the plasma outside the capillary. This study will allow a better understanding of the beam-plasma interaction for future plasma-based experiments.Comment: 5 pages, 6 figures, EAAC 201

    numerical studies on capillary discharges as focusing elements for electron beams

    Get PDF
    Abstract Active plasma lenses are promising technologies for the focusing of high brightness electron beams due to their radially symmetric focusing and their high field gradients (up to several kT/m). However, in a number of experimental situations, the transverse non-uniformity of the current density flowing in the lens causes beam emittance growth and increases the minimum achievable spot size. To study the physics of the capillary discharge processes employed as active plasma lenses, we developed a 2-D hydrodynamic computational model. Here, we present preliminary simulation results and we compare the computed magnetic field profile with one from literature, which has been experimentally inferred. The result of the comparison is discussed

    Temperature analysis in the shock waves regime for gas-filled plasma capillaries in plasma-based accelerators

    Get PDF
    Plasma confinement represents a crucial point for plasma-based accelerators and plasma lenses because it can strongly affect the beam properties. For this reason, an accurate measurement of the plasma parameters, as plasma temperature, pressure and electron density, must be performed. In this paper, we introduce a novel method to detect the plasma temperature and the pressure for gas-filled capillaries in use at the SPARC-LAB test facility. The proposed method is based on the shock waves produced at the ends of the capillary during the gas discharge and the subsequent plasma formation inside it. By measuring the supersonic speed of the plasma outflow, the thermodynamic parameters have been obtained both outside and inside the capillary. A plasma temperature around 1.4 eV has been measured, that depends on the geometric properties and the operating conditions of the capillary

    Focusing of high-brightness electron beams with active-plasma lenses

    Get PDF
    Plasma-based technology promises a tremendous reduction in size of accelerators used for research, medical, and industrial applications, making it possible to develop tabletop machines accessible for a broader scientific community. By overcoming current limits of conventional accelerators and pushing particles to larger and larger energies, the availability of strong and tunable focusing optics is mandatory also because plasma-accelerated beams usually have large angular divergences. In this regard, active-plasma lenses represent a compact and affordable tool to generate radially symmetric magnetic fields several orders of magnitude larger than conventional quadrupoles and solenoids. However, it has been recently proved that the focusing can be highly nonlinear and induce a dramatic emittance growth. Here, we present experimental results showing how these nonlinearities can be minimized and lensing improved. These achievements represent a major breakthrough toward the miniaturization of next-generation focusing devices

    Wake fields effects in dielectric capillary

    Get PDF
    Plasma wake-field acceleration experiments are performed at the SPARC LAB test facility by using a gas-filled capillary plasma source composed of a dielectric capillary. The electron can reach GeV energy in a few centimeters, with an accelerating gradient orders of magnitude larger than provided by conventional techniques. In this acceleration scheme, wake fields produced by passing electron beams through dielectric structures can determine a strong beam instability that represents an important hurdle towards the capability to focus high-current electron beams in the transverse plane. For these reasons, the estimation of the transverse wakefield amplitudes assumes a fundamental role in the implementation of the plasma wake-field acceleration. In this work, it presented a study to investigate which parameters affect the wake-field formation inside a cylindrical dielectric structure, both the capillary dimensions and the beam parameters, and it is introduced a quantitative evaluation of the longitudinal and transverse electric fields

    Overview of Plasma Lens Experiments and Recent Results at SPARC_LAB

    Get PDF
    Beam injection and extraction from a plasma module is still one of the crucial aspects to solve in order to produce high quality electron beams with a plasma accelerator. Proper matching conditions require to focus the incoming high brightness beam down to few microns size and to capture a high divergent beam at the exit without loss of beam quality. Plasma-based lenses have proven to provide focusing gradients of the order of kT/m with radially symmetric focusing thus promising compact and affordable alternative to permanent magnets in the design of transport lines. In this paper an overview of recent experiments and future perspectives of plasma lenses is reported

    Gas-filled Capillaries for Plasma-Based Accelerators

    Get PDF
    Plasma Wakefield Accelerators are based on the excitation of large amplitude plasma waves excited by either a laser or a particle driver beam. The amplitude of the waves, as well as their spatial dimensions and the consequent accelerating gradient depend strongly on the background electron density along the path of the accelerated particles. The process needs stable and reliable plasma sources, whose density profile must be controlled and properly engineered to ensure the appropriate accelerating mechanism. Plasma confinement inside gas filled capillaries have been studied in the past since this technique allows to control the evolution of the plasma, ensuring a stable and repeatable plasma density distribution during the interaction with the drivers. Moreover, in a gas filled capillary plasma can be pre-ionized by a current discharge to avoid ionization losses. Different capillary geometries have been studied to allow the proper temporal and spatial evolution of the plasma along the acceleration length. Results of this analysis obtained by varying the length and the number of gas inlets will be presented

    Co-located ecological data for exploring top- and subsoil carbon dynamics across grassland-woodland contrasts

    Get PDF
    Soil organic carbon (SOC) is a soil health indicator and understanding dynamics changing SOC stocks will help achieving net zero goals. Here we present four datasets featuring 11,750 data points covering co-located aboveground and below-ground metrics for exploring ecosystem SOC dynamics. Five sites across England with an established land use contrast, grassland and woodland next to each other, were rigorously sampled for aboveground (n = 109), surface (n = 33 soil water release curves), topsoil, and subsoil metrics. Commonly measured soil metrics were analysed in five soil increments for 0–1 metre (n = 4550). Less commonly measured soil metrics which were assumed to change across the soil profile were measured on a subset of samples only (n = 3762). Additionally, we developed a simple method for soil organic matter fractionation using density fractionation which is part of the less common metrics. Finally, soil metrics which may impact SOC dynamics, but with less confidence as to their importance across the soil profile were only measured on topsoil (~5–15 cm = mineral soil) and subsoil (below 50 cm) samples (n = 2567)

    Mechanical, antibacterial and bond strength properties of nano-titanium-enriched glass ionomer cement

    Get PDF
    The use of nanoparticles (NPs) has become a significant area of research in Dentistry. Objective The aim of this study was to investigate the physical, antibacterial activity and bond strength properties of conventional base, core build and restorative of glass ionomer cement (GIC) compared to GIC supplemented with titanium dioxide (TiO2) nanopowder at 3% and 5% (w/w). Material and Methods Vickers microhardness was estimated with diamond indenter. Compressive and flexural strengths were analyzed in a universal testing machine. Specimens were bonded to enamel and dentine, and tested for shear bond strength in a universal testing machine. Specimens were incubated with S. mutans suspension for evaluating antibacterial activity. Surface analysis of restorative conventional and modified GIC was performed with SEM and EDS. The analyses were carried out with Kolmogorov-Smirnov, ANOVA (post-hoc), Tukey test, Kruskal-Wallis, and Mann Whitney. Results Conventional GIC and GIC modified with TiO2 nanopowder for the base/liner cement and core build showed no differences for mechanical, antibacterial, and shear bond properties (p>0.05). In contrast, the supplementation of TiO2 NPs to restorative GIC significantly improved Vickers microhardness (p<0.05), flexural and compressive strength (p<0.05), and antibacterial activity (p<0.001), without interfering with adhesion to enamel and dentin. Conclusion GIC supplemented with TiO2 NPs (FX-II) is a promising material for restoration because of its potential antibacterial activity and durable restoration to withstand the mastication force
    corecore