30 research outputs found

    Dysregulated expression of MIG/CXCL9, IP-10/CXCL10 and CXCL16 and their receptors in systemic sclerosis

    Get PDF
    Abstract Introduction Systemic sclerosis (SSc) is characterized by fibrosis and microvascular abnormalities including dysregulated angiogenesis. Chemokines, in addition to their chemoattractant properties, have the ability to modulate angiogenesis. Chemokines lacking the enzyme-linked receptor (ELR) motif, such as monokine induced by interferon-γ (IFN-γ) (MIG/CXCL9) and IFN-inducible protein 10 (IP-10/CXCL10), inhibit angiogenesis by binding CXCR3. In addition, CXCL16 promotes angiogenesis by binding its unique receptor CXCR6. In this study, we determined the expression of these chemokines and receptors in SSc skin and serum. Methods Immunohistology and enzyme-linked immunosorbent assays (ELISAs) were used to determine chemokine and chemokine receptor expression in the skin and serum, respectively, of SSc and normal patients. Endothelial cells (ECs) were isolated from SSc skin biopsies and chemokine and chemokine receptor expression was determined by quantitative PCR and immunofluorescence staining. Results Antiangiogenic IP-10/CXCL10 and MIG/CXCL9 were elevated in SSc serum and highly expressed in SSc skin. However, CXCR3, the receptor for these chemokines, was decreased on ECs in SSc vs. normal skin. CXCL16 was elevated in SSc serum and increased in SSc patients with early disease, pulmonary arterial hypertension, and those that died during the 36 months of the study. In addition, its receptor CXCR6 was overexpressed on ECs in SSc skin. At the mRNA and protein levels, CXCR3 was decreased while CXCR6 was increased on SSc ECs vs. human microvascular endothelial cells (HMVECs). Conclusions These results show that while the expression of MIG/CXCL9 and IP-10/CXCL10 are elevated in SSc serum, the expression of CXCR3 is downregulated on SSc dermal ECs. In contrast, CXCL16 and CXCR6 are elevated in SSc serum and on SSc dermal ECs, respectively. In all, these findings suggest angiogenic chemokine receptor expression is likely regulated in an effort to promote angiogenesis in SSc skin.http://deepblue.lib.umich.edu/bitstream/2027.42/112894/1/13075_2010_Article_3001.pd

    Quantification and reduction of ghosting artifacts in interleaved echo planar imaging. Magn Reson Med

    No full text
    A mathematical analysis of ghosting artifacts often seen in interleaved echo-planar images (EPI) is presented. These artifacts result from phase and amplitude discontinuities between lines of k-space in lhe phase-encoding direction, and timing misregistrations from system filter delays. Phase offsets and time delays are often measured using “reference ” scans, to reduce ghosting through postprcicessing. From the expressions describing ghosting artifacts, criteria were established for reducing ghosting to acceptable levels.. Subsequently, the signal-to-noise ratio (SNR) requirements for estimation of time delays and phase offsets, determined from reference scans, was evaluated to establish the effect of estimation emor on artifact reduction for interleaved EPI. Artifacts resulting from these effects can be reduced to very low levels when appropriate reference scan estimation is used. This has important implications for functional MRI (MRI) and applications involving small changes in signal intensity. Key words: MRI; artifacts; reconstruction; EPI; functional imaging

    Free-breathing radial magnetic resonance elastography of the liver in children at 3 T: a pilot study.

    No full text
    BackgroundMagnetic resonance (MR) elastography of the liver measures hepatic stiffness, which correlates with the histopathological staging of liver fibrosis. Conventional Cartesian gradient-echo (GRE) MR elastography requires breath-holding, which is challenging for children. Non-Cartesian radial free-breathing MR elastography is a potential solution to this problem.ObjectiveTo investigate radial free-breathing MR elastography for measuring hepatic stiffness in children.Materials and methodsIn this prospective pilot study, 14 healthy children and 9 children with liver disease were scanned at 3 T using 2-D Cartesian GRE breath-hold MR elastography (22 s/slice) and 2-D radial GRE free-breathing MR elastography (163 s/slice). Each sequence was acquired twice. Agreement in the stiffness measurements was evaluated using Lin's concordance correlation coefficient (CCC) and within-subject mean difference. The repeatability was assessed using the within-subject coefficient of variation and intraclass correlation coefficient (ICC).ResultsFourteen healthy children and seven children with liver disease completed the study. Median (±interquartile range) normalized measurable liver areas were 62.6% (±26.4%) and 44.1% (±39.6%) for scan 1, and 60.3% (±21.8%) and 43.9% (±44.2%) for scan 2, for Cartesian and radial techniques, respectively. Hepatic stiffness from the Cartesian and radial techniques had close agreement with CCC of 0.89 and 0.94, and mean difference of 0.03 kPa and -0.01 kPa, for scans 1 and 2. Cartesian and radial techniques achieved similar repeatability with within-subject coefficient of variation=1.9% and 3.4%, and ICC=0.93 and 0.92, respectively.ConclusionIn this pilot study, radial free-breathing MR elastography was repeatable and in agreement with Cartesian breath-hold MR elastography in children

    MR elastography outperforms shear wave elastography for the diagnosis of clinically significant portal hypertension

    Full text link
    OBJECTIVES Portal hypertension (PH) is associated with complications such as ascites and esophageal varices and is typically diagnosed through invasive hepatic venous pressure gradient (HVPG) measurement, which is not widely available. In this study, we aim to assess the diagnostic performance of 2D/3D MR elastography (MRE) and shear wave elastography (SWE) measures of liver and spleen stiffness (LS and SS) and spleen volume, to noninvasively diagnose clinically significant portal hypertension (CSPH) using HVPG measurement as the reference. METHODS In this prospective study, patients with liver disease underwent 2D/3D MRE and SWE of the liver and spleen, as well as HVPG measurement. The correlation between MRE/SWE measures of LS/SS and spleen volume with HVPG was assessed. ROC analysis was used to determine the utility of MRE, SWE, and spleen volume for diagnosing CSPH. RESULTS Thirty-six patients (M/F 22/14, mean age 55 ± 14 years) were included. Of the evaluated parameters, 3D MRE SS had the strongest correlation with HVPG (r = 0.686, p < 0.001), followed by 2D MRE SS (r = 0.476, p = 0.004). 3D MRE SS displayed the best performance for diagnosis of CSPH (AUC = 0.911) followed by 2D MRE SS (AUC = 0.845) and 3D MRE LS (AUC = 0.804). SWE SS showed poor performance for diagnosis of CSPH (AUC = 0.583) while spleen volume was a fair predictor (AUC = 0.738). 3D MRE SS was significantly superior to SWE LS/SS (p ≤ 0.021) for the diagnosis of CSPH. CONCLUSION SS measured with 3D MRE outperforms SWE for the diagnosis of CSPH. SS appears to be a useful biomarker for assessing PH severity. These results need further validation. KEY POINTS • Spleen stiffness measured with 2D and 3D MR elastography correlates significantly with hepatic venous pressure gradient measurement. • Spleen stiffness measured with 3D MR elastography demonstrates excellent performance for the diagnosis of clinically significant portal hypertension (AUC 0.911). • Spleen stiffness measured with 3D MR elastography outperforms liver and spleen stiffness measured with shear wave elastography for diagnosis of clinically significant portal hypertension