    Portable HEPA Filter Air Cleaner Use During Pregnancy and Children’s Behavior Problem Scores: A Secondary Analysis of the UGAAR Randomized Controlled Trial

    Get PDF
    Background Developmental exposure to particulate matter (PM) air pollution may impair children’s behaviors. Our objectives were to quantify the impact of reducing indoor PM using portable HEPA filter air cleaners during pregnancy on behavioral problems in children and to assess associations between indoor fine PM (PM2.5) concentrations during pregnancy and children’s behavior.   Methods This is a secondary analysis of a single-blind parallel-group randomized controlled trial in which we randomly assigned 540 non-smoking pregnant women to receive 1 or 2 HEPA filter air cleaners or no air cleaners. We administered the Behavior Assessment System for Children (BASC-3) to caregivers when children were a mean age of 23 months, and again at a mean age of 48 months. Primary outcomes were the four BASC-3 composite scales: externalizing problems, internalizing problems, adaptive skills, and the behavioral symptoms index. We imputed missing data using multiple imputation with chained equations. The primary analysis was by intention-to-treat. In a secondary analysis, we evaluated associations between BASC-3 composite indices and modeled trimester-specific PM2.5 concentrations inside residences.   Results We enrolled participants at a median of 11 weeks gestation. After excluding miscarriages, still births and neonatal deaths, our analysis included 478 children (233 control and 245 intervention). We observed no differences in the mean BASC-3 scores between treatment groups. An interquartile increase (20.1 µg/m3) in first trimester PM2.5 concentration was associated with higher externalizing problem scores (2.4 units, 95% CI: 0.7, 4.1), higher internalizing problem scores (2.4 units, 95% CI: 0.7, 4.0), lower adaptive skills scores (-1.5 units, 95% CI: -3.0, 0.0), and higher behavior symptoms index scores (2.3 units, 95% CI: 0.7, 3.9). Third trimester PM2.5 concentrations were also associated with some behavioral indices at age 4, but effect estimates were smaller. No significant associations were observed with PM2.5 concentrations during the second trimester or for any of the BASC indices when children were 2 years old.   Conclusion We found no benefit of reducing indoor particulate air pollution during pregnancy on parent-reported behaviors in children. Associations between indoor PM2.5 concentrations in the first trimester and behavioral scores among 4-year old children suggest that it may be necessary to intervene early in pregnancy to protect children, but these exploratory findings should be interpreted cautiously

    The effect of portable HEPA filter air cleaners on indoor PM2.5 concentrations and second hand tobacco smoke exposure among pregnant women in Ulaanbaatar, Mongolia: The UGAAR randomized controlled trial

    Get PDF
    Background Portable HEPA filter air cleaners can reduce indoor fine particulate matter (PM2.5), but their use has not been adequately evaluated in high pollution settings. We assessed air cleaner effectiveness in reducing indoor residential PM2.5 and second hand smoke (SHS) exposures among non-smoking pregnant women in Ulaanbaatar, Mongolia. Methods We randomized 540 participants to an intervention group receiving 1 or 2 HEPA filter air cleaners or a control group receiving no air cleaners. We followed 259 intervention and 253 control participants to the end of pregnancy. We measured one-week indoor residential PM2.5 concentrations in early (~11weeks gestation) and late (~31weeks gestation) pregnancy and collected outdoor PM2.5 data from centrally-located government monitors. We assessed blood cadmium in late pregnancy. Hair nicotine was quantified in a subset (n=125) to evaluate blood cadmium as a biomarker of SHS exposure. We evaluated air cleaner effectiveness using mixed effects and multiple linear regression models and used stratified models and interaction terms to evaluate potential modifiers of effectiveness. Results The overall geometric mean (GM) one-week outdoor PM2.5 concentration was 47.9?g/m3 (95% CI: 44.6, 51.6?g/m3), with highest concentrations in winter (118.0?g/m3; 110.4, 126.2?g/m3). One-week indoor and outdoor PM2.5 concentrations were correlated (r=0.69). Indoor PM2.5 concentrations were 29% (21, 37%) lower in intervention versus control apartments, with GMs of 17.3?g/m3 (15.8, 18.8?g/m3) and 24.5?g/m3 (22.2, 27.0?g/m3), respectively. Air cleaner effectiveness was greater when air cleaners were first deployed (40%; 31, 48%) than after approximately five months of use (15%; 0, 27%). Blood cadmium concentrations were 14% (4, 23%) lower among intervention participants, likely due to reduced SHS exposure. Conclusions Portable HEPA filter air cleaners can lower indoor PM2.5 concentrations and SHS exposures in highly polluted settings.Canadian Institute of Health Research (MOP 142380)Simon Fraser University, Faculty of Health Sciences (Mowafaghian Child Health Faculty Award

    The effect of portable HEPA filter air cleaners on indoor PM2.5 concentrations and second hand tobacco smoke exposure among pregnant women in Ulaanbaatar, Mongolia: The UGAAR randomized controlled trial

    Get PDF
    Background Portable HEPA filter air cleaners can reduce indoor fine particulate matter (PM2.5), but their use has not been adequately evaluated in high pollution settings. We assessed air cleaner effectiveness in reducing indoor residential PM2.5 and second hand smoke (SHS) exposures among non-smoking pregnant women in Ulaanbaatar, Mongolia. Methods We randomized 540 participants to an intervention group receiving 1 or 2 HEPA filter air cleaners or a control group receiving no air cleaners. We followed 259 intervention and 253 control participants to the end of pregnancy. We measured one-week indoor residential PM2.5 concentrations in early (~11weeks gestation) and late (~31weeks gestation) pregnancy and collected outdoor PM2.5 data from centrally-located government monitors. We assessed blood cadmium in late pregnancy. Hair nicotine was quantified in a subset (n=125) to evaluate blood cadmium as a biomarker of SHS exposure. We evaluated air cleaner effectiveness using mixed effects and multiple linear regression models and used stratified models and interaction terms to evaluate potential modifiers of effectiveness. Results The overall geometric mean (GM) one-week outdoor PM2.5 concentration was 47.9?g/m3 (95% CI: 44.6, 51.6?g/m3), with highest concentrations in winter (118.0?g/m3; 110.4, 126.2?g/m3). One-week indoor and outdoor PM2.5 concentrations were correlated (r=0.69). Indoor PM2.5 concentrations were 29% (21, 37%) lower in intervention versus control apartments, with GMs of 17.3?g/m3 (15.8, 18.8?g/m3) and 24.5?g/m3 (22.2, 27.0?g/m3), respectively. Air cleaner effectiveness was greater when air cleaners were first deployed (40%; 31, 48%) than after approximately five months of use (15%; 0, 27%). Blood cadmium concentrations were 14% (4, 23%) lower among intervention participants, likely due to reduced SHS exposure. Conclusions Portable HEPA filter air cleaners can lower indoor PM2.5 concentrations and SHS exposures in highly polluted settings.Canadian Institute of Health Research (MOP 142380)Simon Fraser University, Faculty of Health Sciences (Mowafaghian Child Health Faculty Award