490 research outputs found
The composition of cosmic rays near the Bend (10 to the 15th power eV) from a study of muons in air showers at sea level
The distribution of muons near shower cores was studied at sea level at Fermilab using the E594 neutrino detector to sample the muon with E testing 3 GeV. These data are compared with detailed Monte Carlo simulations to derive conclusions about the composition of cosmic rays near the bend in the all particle spectrum. Monte Carlo simulations generating extensive air showers (EAS) with primary energy in excess of 50 TeV are described. Each shower record contains details of the electron lateral distribution and the muon and hadron lateral distributions as a function of energy, at the observation level of 100g/cm. The number of detected electrons and muons in each case was determined by a Poisson fluctuation of the number incident. The resultant predicted distribution of muons, electrons, the rate events are compared to those observed. Preliminary results on the rate favor a heavy primary dominated cosmic ray spectrum in energy range 50 to 1000 TeV
Leptoproduction of Heavy Quarks II -- A Unified QCD Formulation of Charged and Neutral Current Processes from Fixed-target to Collider Energies
A unified QCD formulation of leptoproduction of massive quarks in charged
current and neutral current processes is described. This involves adopting
consistent factorization and renormalization schemes which encompass both
vector-boson-gluon-fusion (flavor creation) and
vector-boson-massive-quark-scattering (flavor excitation) production
mechanisms. It provides a framework which is valid from the threshold for
producing the massive quark (where gluon-fusion is dominant) to the very high
energy regime when the typical energy scale \mu is much larger than the quark
mass m_Q (where the quark-scattering should be prevalent). This approach
effectively resums all large logarithms of the type (alpha_s(mu)
log(mu^2/m_Q^2)^n which limit the validity of existing fixed-order calculations
to the region mu ~ O(m_Q). We show that the (massive) quark-scattering
contribution (after subtraction of overlaps) is important in most parts of the
(x, Q) plane except near the threshold region. We demonstrate that the
factorization scale dependence of the structure functions calculated in this
approach is substantially less than those obtained in the fixed-order
calculations, as one would expect from a more consistent formulation.Comment: LaTeX format, 29 pages, 11 figures. Revised to make auto-TeX-abl
Effect of zoledronic acid on the doxycycline-induced decrease in tumour burden in a bone metastasis model of human breast cancer
Bone is one of the most frequent sites for metastasis in breast cancer patients often resulting in significant clinical morbidity and mortality. Bisphosphonates are currently the standard of care for breast cancer patients with bone metastasis. We have shown previously that doxycycline, a member of the tetracycline family of antibiotics, reduces total tumour burden in an experimental bone metastasis mouse model of human breast cancer. In this study, we combined doxycycline treatment together with zoledronic acid, the most potent bisphosphonate. Drug administration started 3 days before the injection of the MDA-MB-231 cells. When mice were administered zoledronic acid alone, the total tumour burden decreased by 43% compared to placebo treatment. Administration of a combination of zoledronic acid and doxycycline resulted in a 74% decrease in total tumour burden compared to untreated mice. In doxycycline- and zoledronate-treated mice bone formation was significantly enhanced as determined by increased numbers of osteoblasts, osteoid surface and volume, whereas a decrease in bone resorption was also observed. Doxycycline greatly reduced tumour burden and could also compensate for the increased bone resorption. The addition of zoledronate to the regimen further decreased tumour burden, caused an extensive decrease in bone-associated soft tissue tumour burden (93%), and sustained the bone volume, which could result in a smaller fracture risk. Treatment with zoledronic acid in combination with doxycycline may be very beneficial for breast cancer patients at risk for osteolytic bone metastasis
Organometallic iridium(III) anticancer complexes with new mechanisms of action: NCI-60 screening, mitochondrial targeting, and apoptosis
Platinum complexes related to cisplatin, cis-[PtCl2(NH3)2], are successful anticancer drugs; however, other transition metal complexes offer potential for combating cisplatin resistance, decreasing side effects, and widening the spectrum of activity. Organometallic half-sandwich iridium (IrIII) complexes [Ir(Cpx)(XY)Cl]+/0 (Cpx = biphenyltetramethylcyclopentadienyl and XY = phenanthroline (1), bipyridine (2), or phenylpyridine (3)) all hydrolyze rapidly, forming monofunctional G adducts on DNA with additional intercalation of the phenyl substituents on the Cpx ring. In comparison, highly potent complex 4 (Cpx = phenyltetramethylcyclopentadienyl and XY = N,N-dimethylphenylazopyridine) does not hydrolyze. All show higher potency toward A2780 human ovarian cancer cells compared to cisplatin, with 1, 3, and 4 also demonstrating higher potency in the National Cancer Institute (NCI) NCI-60 cell-line screen. Use of the NCI COMPARE algorithm (which predicts mechanisms of action (MoAs) for emerging anticancer compounds by correlating NCI-60 patterns of sensitivity) shows that the MoA of these IrIII complexes has no correlation to cisplatin (or oxaliplatin), with 3 and 4 emerging as particularly novel compounds. Those findings by COMPARE were experimentally probed by transmission electron microscopy (TEM) of A2780 cells exposed to 1, showing mitochondrial swelling and activation of apoptosis after 24 h. Significant changes in mitochondrial membrane polarization were detected by flow cytometry, and the potency of the complexes was enhanced ca. 5× by co-administration with a low concentration (5 μM) of the γ-glutamyl cysteine synthetase inhibitor L-buthionine sulfoximine (L-BSO). These studies reveal potential polypharmacology of organometallic IrIII complexes, with MoA and cell selectivity governed by structural changes in the chelating ligands
Measurement of the Atmospheric Muon Charge Ratio at TeV Energies with MINOS
The 5.4 kton MINOS far detector has been taking charge-separated cosmic ray
muon data since the beginning of August, 2003 at a depth of 2070
meters-water-equivalent in the Soudan Underground Laboratory, Minnesota, USA.
The data with both forward and reversed magnetic field running configurations
were combined to minimize systematic errors in the determination of the
underground muon charge ratio. When averaged, two independent analyses find the
charge ratio underground to be 1.374 +/- 0.004 (stat.) +0.012 -0.010(sys.).
Using the map of the Soudan rock overburden, the muon momenta as measured
underground were projected to the corresponding values at the surface in the
energy range 1-7 TeV. Within this range of energies at the surface, the MINOS
data are consistent with the charge ratio being energy independent at the two
standard deviation level. When the MINOS results are compared with measurements
at lower energies, a clear rise in the charge ratio in the energy range 0.3 --
1.0 TeV is apparent. A qualitative model shows that the rise is consistent with
an increasing contribution of kaon decays to the muon charge ratio.Comment: 16 pages, 17 figure
Recommended from our members
A Measurement of the Hadronic Component of Air Showers in a Fine Grained Calorimeter
The hadronic component of extensive air showers is studied using the E594 fine grained calorimeter and a air shower array trigger. Hadron angle and energy distributions are shown. Events with more than one separated hadron with substantial energy are studied carefully. The correlation of hadronic and muonic components is shown. 2 refs., 3 figs
Recommended from our members
Measurement of the underground atmospheric muon charge ratio using the MINOS Near Detector
The magnetized MINOS Near Detector, at a depth of 225 mwe, is used to measure the atmospheric muon charge ratio. The ratio of observed positive to negative atmospheric muon rates, using 301 days of data, is measured to be 1.266±0.001(stat)_(-0.014)^(+0.015)(syst). This measurement is consistent with previous results from other shallow underground detectors and is 0.108±0.019(stat+syst) lower than the measurement at the functionally identical MINOS Far Detector at a depth of 2070 mwe. This increase in charge ratio as a function of depth is consistent with an increase in the fraction of muons arising from kaon decay for increasing muon surface energie
Measurement of neutrino velocity with the MINOS detectors and NuMI neutrino beam
The velocity of a ~3 GeV neutrino beam is measured by comparing detection times at the near and far detectors of the MINOS experiment, separated by 734 km. A total of 473 far detector neutrino events was used to measure (v-c)/c=5.12.910-5 (at 68% C.L.). By correlating the measured energies of 258 charged-current neutrino events to their arrival times at the far detector, a limit is imposed on the neutrino mass of mnu<50 MeV/c2 (99% C.L.)
- …