6 research outputs found

    Subcutaneous implantable cardioverter-defibrillators: long-term results of the EFFORTLESS study

    Get PDF
    AIMS: To report 5-year outcomes of EFFORTLESS registry patients with early generation subcutaneous implantable cardioverter-defibrillator (S-ICD) devices. METHODS AND RESULTS: Kaplan-Meier, trend and multivariable analyses were performed for mortality and late (years 2-5) complications, appropriate shock (AS) and inappropriate shock (IAS) rates. Nine hundred and eighty-four of 994 enrolled patients with diverse diagnoses (28% female, 48 ± 17 years, body mass index 27 ± 6 kg/m2, ejection fraction 43 ± 18%) underwent S-ICD implantation. Median follow-up was 5.1 years (interquartile range 4.7-5.5 years). All-cause mortality was 9.3% (95% confidence interval 7.2-11.3%) at 5 years; 703 patients remained in follow-up on study completion, 171 withdrew including 87 (8.8%) with device explanted, and 65 (6.6%) lost to follow-up. Of the explants, only 20 (2.0%) patients needed a transvenous device for pacing indications. First and final shock efficacy for discrete ventricular arrhythmias was consistent at 90% and 98%, respectively, with storm episode final shock efficacy at 95.2%. Time to therapy remained unaltered. Overall 1- and 5-year complication rates were 8.9% and 15.2%, respectively. Early complications did not predict later complications. There were no structural lead failures. Inappropriate shock rates at 1 and 5 years were 8.7% and 16.9%, respectively. Self-terminating inappropriately sensed episodes predicted late IAS. Predictors of late AS included self-terminating appropriately sensed episodes and earlier AS. CONCLUSION: In this diverse S-ICD registry population, spontaneous shock efficacy was consistently high over 5 years. Very few patients underwent S-ICD replacement with a transvenous device for pacing indications. Treated and self-terminating arrhythmic episodes predict future shock events, which should encourage more personalized device optimization. KEY QUESTION: Is subcutaneous implantable cardioverter-defibrillator (S-ICD) shock efficacy maintained over time? KEY FINDING: Subcutaneous implantable cardioverter-defibrillator shock efficacy remains high for discrete and storm episodes. For discrete episodes first and final shock efficacy do not change over time or by rhythm type. TAKE-HOME MESSAGE: The EFFORTLESS study 5-year results provide the longest follow up of a large patient cohort implanted with the S-ICD. For 984 patients with a median follow-up of 5.1 years, the S-ICD maintains a high level of shock efficacy of 98%

    Longevity of the subcutaneous implantable defibrillator long-term follow-up of the European Regulatory Trial Cohort

    No full text
    Background: The recent advent of subcutaneous implantable cardioverter defibrillators (S-ICDs) has provided investigators with a safe and effective new therapy in patients at risk of sudden cardiac death. At present, no data are available with regard to the longevity of these new devices. This study evaluated the longevity of the S-ICD system. Methods and Results: All patients enrolled in the European Regulatory Trial were included in the analysis. During follow-up, time and causes of device replacement or explantation were assessed and categorized. Device longevity was estimated using Kaplan-Meier analysis. Fifty-five patients were followed for a median of 5.8 years. During follow-up, 26 (47%) patients underwent device replacement and 5 (9%) underwent device explantation. Median time to replacement was 5.0 years (Q1-Q3, 4.4-5.6 years). Replacement was caused by battery depletion in 25 patients (92%), of which 5 within 1.5 years because of premature battery depletion, and by infection in 1 patient (2%). Replacement for a transvenous ICD system was required in 4 patients (7%) because of ineffective defibrillation in 1 (0.003 per patient-year), need for resynchronization therapy in 2 (0.01 per patient-year), and for antibradycardia pacing in 1 (0.003 per patient-year). At 5 years follow-up, 71% of devices were still in service. Conclusions: This study provides the first estimate of S-ICD system longevity since its introduction in clinical practice. Median longevity of the first generation S-ICD system was 5.0 years. The majority of devices were replaced because of battery depletion. Clinical Trial Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT01117792

    Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial

    No full text
    BackgroundThe subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in typical transvenous ICD trials. The UNTOUCHED trial (Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction) was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms.MethodsPrimary prevention patients with left ventricular ejection fraction ≤35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥250 beats per minute and morphology discrimination for rates ≥200 and ResultsS-ICD implant was attempted in 1116 patients, and 1111 patients were included in postimplant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% were women, 23.4% were Black, 53.5% had ischemic heart disease, 87.7% had symptomatic heart failure, and the mean left ventricular ejection fraction was 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (lower confidence limit, 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the 3-incision technique, no history of atrial fibrillation, and ischemic cause. The 18-month all-cause shock-free rate was 90.6% (lower confidence limit, 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication-free rate at 18 months was 92.7%.ConclusionsThis study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of comorbidities in comparison with earlier S-ICD trials. The inappropriate shock rate (3.1% at 1 year) is the lowest reported for the S-ICD and lower than many transvenous ICD studies using contemporary programming to reduce IAS. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02433379.</div

    Design and rationale of DUTCH-AF: a prospective nationwide registry programme and observational study on long-term oral antithrombotic treatment in patients with atrial fibrillation

    No full text
    INTRODUCTION: Anticoagulation therapy is pivotal in the management of stroke prevention in atrial fibrillation (AF). Prospective registries, containing longitudinal data are lacking with detailed information on anticoagulant therapy, treatment adherence and AF-related adverse events in practice-based patient cohorts, in particular for non-vitamin K oral anticoagulants (NOAC). With the creation of DUTCH-AF, a nationwide longitudinal AF registry, we aim to provide clinical data and answer questions on the (anticoagulant) management over time and of the clinical course of patients with newly diagnosed AF in routine clinical care. Within DUTCH-AF, our current aim is to assess the effect of non-adherence and non-persistence of anticoagulation therapy on clinical adverse events (eg, bleeding and stroke), to determine predictors for such inadequate anticoagulant treatment, and to validate and refine bleeding prediction models. With DUTCH-AF, we provide the basis for a continuing nationwide AF registry, which will facilitate subsequent research, including future registry-based clinical trials. METHODS AND ANALYSIS: The DUTCH-AF registry is a nationwide, prospective registry of patients with newly diagnosed 'non-valvular' AF. Patients will be enrolled from primary, secondary and tertiary care practices across the Netherlands. A target of 6000 patients for this initial cohort will be followed for at least 2 years. Data on thromboembolic and bleeding events, changes in antithrombotic therapy and hospital admissions will be registered. Pharmacy-dispensing data will be obtained to calculate parameters of adherence and persistence to anticoagulant treatment, which will be linked to AF-related outcomes such as ischaemic stroke and major bleeding. In a subset of patients, anticoagulation adherence and beliefs about drugs will be assessed by questionnaire. ETHICS AND DISSEMINATION: This study protocol was approved as exempt for formal review according to Dutch law by the Medical Ethics Committee of the Leiden University Medical Centre, Leiden, the Netherlands. Results will be disseminated by publications in peer-reviewed journals and presentations at scientific congresses. TRIAL REGISTRATION NUMBER: Trial NL7467, NTR7706 (https://www.trialregister.nl/trial/7464)
    corecore