377 research outputs found
Quick scan rapport van productie van koelverse pizza's bij Hazlewood Food Liessel B.V. : concept
Kwaliteitsontwikkeling van niet en wel verpakte komkommers en paprika's in de distributieketen van Schuitema
A review on equipment protection and system protection relay in power system
Power system equipment is configured and connected together with multiple voltage levels in existing electrical power system. There are varieties of electrical equipment obtainable in the power system predominantly from generation side up to the distribution side. Consequently, appropriate protections must be apt to prevent inessential disturbances that lead to voltage instability, voltage collapse and sooner a total blackout took place in the power system. The understanding of each component on the system protection is critical. This is due to any abnormal condition and failure can be analyzed and solved effectively due to the rapid changing and development on the power system network. Therefore, the enhancement of power quality can be achieved by sheltering the equipment with protection relay in power system. Moreover, the design of a systematic network is crucial for the system protection itself. Several types of protective equipment and protection techniques are taken into consideration in this paper. Hence, the existing accessible types and methods of system protection in the power system network are reviewed
Ab initio simulations of liquid NaSn alloys: Zintl anions and network formation
Using the Car-Parrinello technique, ab initio molecular dynamics simulations
are performed for liquid NaSn alloys in five different compositions (20, 40,
50, 57 and 80 % sodium). The obtained structure factors agree well with the
data from neutron scattering experiments. The measured prepeak in the structure
factor is reproduced qualitatively for most compositions. The calculated and
measured positions of all peaks show the same trend as function of the
composition.\\ The dynamic simulations also yield information about the
formation and stability of Sn clusters (Zintl anions) in the liquid. In our
simulations of compositions with 50 and 57 % sodium we observe the formation of
networks of tin atoms. Thus, isolated tin clusters are not stable in such
liquids. For the composition with 20 % tin only isolated atoms or dimers of tin
appear, ``octet compounds'' of one Sn atom surrounded by 4 Na atoms are not
observed.Comment: 12 pages, Latex, 3 Figures on reques
Objektieve beoordeling en verbetering van de kwaliteit van Nederlandse spruiten : in opdracht van Produktschap van Groenten en Fruit, Centraal Bureau Tuinbouwveilingen, Frugifera B.V
Легочная гипертензия при диастолической дисфункции левого желудочка у больных с ишемической кардиомиопатией
На основании данных эхокардиографического исследования выявлена взаимосвязь между степенью легочной гипертензии и тяжестью диастолической дисфункции левого желудочка у больных с ишемической кардиомиопатией. Показано, что рестриктиное наполнение левого желудочка наблюдается в основном при выраженной легочной гипертензии.The findings of echocardiography were used to reveal interrelation between the degree of pulmonary hypertension and severity of diastolic dysfunction of the left ventricle in patients with ischemic cardiomyopathy. Restrictive filling of the left ventricle is shown to be observed in marked pulmonary hypertension
Adsorption of CO on a Platinum (111) surface - a study within a four-component relativistic density functional approach
We report on results of a theoretical study of the adsorption process of a
single carbon oxide molecule on a Platinum (111) surface. A four-component
relativistic density functional method was applied to account for a proper
description of the strong relativistic effects. A limited number of atoms in
the framework of a cluster approach is used to describe the surface. Different
adsorption sites are investigated. We found that CO is preferably adsorbed at
the top position.Comment: 23 Pages with 4 figure
- …