861 research outputs found

    Speciation and Bioavailability Measurements of Environmental Plutonium Using Diffusion in Thin Films.

    Get PDF
    The biological uptake of plutonium (Pu) in aquatic ecosystems is of particular concern since it is an alpha-particle emitter with long half-life which can potentially contribute to the exposure of biota and humans. The diffusive gradients in thin films technique is introduced here for in-situ measurements of Pu bioavailability and speciation. A diffusion cell constructed for laboratory experiments with Pu and the newly developed protocol make it possible to simulate the environmental behavior of Pu in model solutions of various chemical compositions. Adjustment of the oxidation states to Pu(IV) and Pu(V) described in this protocol is essential in order to investigate the complex redox chemistry of plutonium in the environment. The calibration of this technique and the results obtained in the laboratory experiments enable to develop a specific DGT device for in-situ Pu measurements in freshwaters. Accelerator-based mass-spectrometry measurements of Pu accumulated by DGTs in a karst spring allowed determining the bioavailability of Pu in a mineral freshwater environment. Application of this protocol for Pu measurements using DGT devices has a large potential to improve our understanding of the speciation and the biological transfer of Pu in aquatic ecosystems

    Using a NPWE model observer to assess suitable image quality for a digital mammography quality assurance programme

    Get PDF
    A method of objectively determining imaging performance for a mammography quality assurance programme for digital systems was developed. The method is based on the assessment of the visibility of a spherical microcalcification of 0.2 mm using a quasi-ideal observer model. It requires the assessment of the spatial resolution (modulation transfer function) and the noise power spectra of the systems. The contrast is measured using a 0.2-mm thick Al sheet and Polymethylmethacrylate (PMMA) blocks. The minimal image quality was defined as that giving a target contrast-to-noise ratio (CNR) of 5.4. Several evaluations of this objective method for evaluating image quality in mammography quality assurance programmes have been considered on computed radiography (CR) and digital radiography (DR) mammography systems. The measurement gives a threshold CNR necessary to reach the minimum standard image quality required with regards to the visibility of a 0.2-mm microcalcification. This method may replace the CDMAM image evaluation and simplify the threshold contrast visibility test used in mammography qualit

    Temporal Trends in Low-Dose Aspirin Use (from the CoLaus|PsyCoLaus Study).

    Get PDF
    Although established in secondary prevention, the use of low-dose aspirin for primary cardiovascular prevention remains uncertain. We assessed the temporal trend of low-dose aspirin use in people at primary and secondary prevention over 14 years. We used data from the population-based CoLaus|PsyCoLaus study. A baseline survey was conducted from 2003 to 2006, involving 6,733 participants. The first and second follow-up investigations were performed from 2009 to 2012 and 2014 to 2017, respectively. Low-dose aspirin use was defined as ≤300 mg/daily oral administration or administration of an anticoagulant for similar indications. For primary prevention analysis, 6,555, 4,695, and 3,893 participants were included in the analysis at baseline, first and second follow-ups, respectively. Overall, low-dose aspirin use doubled between baseline (4.1%) and second follow-up (8.1%). Appropriate use of low-dose aspirin rose from 32% at baseline to 64% at the second follow-up for primary prevention. In secondary prevention, 71.8%, 75.9%, and 71.7% of participants were taking low-dose aspirin at baseline, first, and second follow-up, respectively. On the basis of a population-based cohort, the appropriateness of low-dose aspirin use increased over a 10-year follow-up in primary prevention, but its inappropriate use still concerned 44% of subjects. In secondary prevention, a quarter of individuals were not taking low-dose aspirin which remained stable over the analyzed period

    Low birth weight leads to obesity, diabetes and increased leptin levels in adults: the CoLaus study.

    Get PDF
    Low birth weight is associated with increased rates of obesity, insulin resistance and type 2 diabetes, but the precise mechanisms for this association remain unclear. We aimed to assess the relationships between birth weight and markers of glucose homeostasis or obesity in adults. Cross-sectional population-based study on 1458 women and 1088 men aged 35-75 years living in Lausanne, Switzerland. Birth weight was self-reported and categorized into ≤ 2.5, 2.6-3.5, 3.6-4.0 and >4.0 kg. Body composition was assessed by bioimpedance. Leptin and adiponectin levels were measured by ELISA. Women with low birth weight (≤ 2.5 kg) had higher levels of fasting plasma glucose, insulin, HOMA, diabetes and metabolic syndrome; a non significant similar trend was seen in men. In both genders, height increased with birth weight, whereas a U-shaped association was found between birth weight and body mass index, waist circumference and body fat percentage. After adjusting for age, smoking status, physical activity and fat mass, an inverse association was found between leptin and birth weight categories: adjusted mean ± standard error 17.3 ± 0.7, 16.2 ± 0.3, 15.6 ± 0.5 and 14.0 ± 0.8 ng/dL for birth weight categories ≤ 2.5, 2.6-3.5, 3.6-4.0 and >4.0 kg, respectively, in women (p < 0.05) and 9.8 ± 0.8, 9.1 ± 03, 7.8 ± 0.4 and 7.7 ± 0.5 ng/dL in men (p < 0.05). An inverse association was also found between reported birth weight and leptin to fat mass ratio: mean ± standard error 0.77 ± 0.04, 0.73 ± 0.02, 0.69 ± 0.03 and 0.62 ± 0.04 in women (p < 0.05); 0.46 ± 0.05, 0.45 ± 0.02, 0.39 ± 0.02 and 0.38 ± 0.03 in men (p < 0.05). No differences in adiponectin levels were found between birth weight groups. Middle-aged adults born with a low weight present a higher prevalence of diabetes and obesity and also higher leptin levels and leptin to fat mass ratio than adults born with a normal weight. The higher leptin levels and leptin to fat mass ratio among adults born with a low weight might be related to nutritional factors during childhood or to the development of leptin resistance and/or higher leptin production by body fat unit. Subjects born with a low weight should be counselled regarding the risks of developing diabetes and/or cardiovascular disease

    Sociodemographic and Behavioural Determinants of a Healthy Diet in Switzerland.

    Get PDF
    BACKGROUND/AIMS: The determinants of a healthy diet have not been studied in Switzerland. This study aimed at assessing the individual and behavioural factors associated with a healthy diet in a Swiss city. METHODS: Cross-sectional, population-based study conducted between 2009 and 2013 (n = 4,439, 2,383 women, mean age 57.5 ± 10.3 years) in Lausanne. Food consumption was assessed using a validated food frequency questionnaire. Two Mediterranean diet scores (classic score and specific for Switzerland) and the Harvard School of Public Health alternate healthy eating index were computed. RESULTS: For all three dietary scores considered, living in couple or having a high education were associated with a healthier diet. An unhealthy lifestyle (smoking, sedentary behaviour) or a high body mass index were associated with an unhealthier diet. Participants born in Italy, Portugal and Spain had healthier diets than participants born in France or Switzerland. Women and elderly participants had healthier diets than men and young participants according to 2 scores, while no differences were found for the Swiss-specific Mediterranean score. CONCLUSIONS: In Switzerland, healthy eating is associated with high education, a healthy lifestyle, marital status and country of origin. The associations with gender and age depend on the dietary score considered

    Bacteremia Due to Viridans Streptococcus in Neutropenic Patients with Cancer: Clinical Spectrum and Risk Factors

    Get PDF
    Between 1988 and 1991, 26 episodes of bacteremia due to viridans streptococci occurred in 25 neutropenic patients undergoing intensive chemotherapy for hematologic malignancies. Complications related to the bacteremia were observed in 10 episodes: unilateral pulmonary infiltrates (4), acute respiratory distress syndrome (ARDS) (4), hypotension (3), and endocarditis (2). All patients with ARDS had received high doses of cytosine arabinoside and had bacteremia due to Streptococcus mitis. Death occurred in three patients (12%) but was possibly related to bacteremia in only one case. Case patients who had received prophylaxis with quinolones were compared with matched control patients who received similar prophylaxis but who did not have bacteremia due to viridans streptococci. Multivariate analysis of predisposing factors showed that high doses of cytosine arabinoside (P = .01), the presence of mucositis (P = .02), and the absence of previous therapy with parenteral antibiotics (P = .01) were independent risk factors for the development of viridans streptococcal bacteremia. Of 259 patients who had received quinolone prophylaxis during the study period, 22 (8.5%) developed an episode of viridans streptococcal bacteremia as compared with three episodes (3.7%) in 82 patients who had received a quinolone and penicillin (P = .07). However, the latter three episodes were caused by strains with decreased susceptibility to penicillin, thus suggesting that resistance to penicillin might limit the use of this antibiotic as a prophylactic agent in the futur

    Calibration of an HPGe detector and self-attenuation correction for Pb-210: Verification by alpha spectrometry of Po-210 in environmental samples

    Get PDF
    In this work the calibration of an HPGe detector for Pb-210 measurement is realised by a liquid standard source and the determination of this radionuclide in solid environmental samples by gamma spectrometry takes into account a correction factor for self-attenuation of its 46.5 keV line. Experimental, theoretical and Monte Carlo investigations are undertaken to evaluate self-attenuation for cylindrical sample geometry. To validate this correction factor (at equilibrium with Po-210 Pb-210) alpha spectrometry procedure using microwave acid digestion under pressure is developed and proposed. The different self-attenuation correction methods are in coherence, and corrected Pb-210 activities are in good agreement with the results of Po-210. Finally, self-attenuation corrections are proposed for environmental solid samples whose density ranges between 0.8 and 1.4 g/cm(3) and whose mass attenuation coefficient is around 0.4 cm(2)/g. (C) 2007 Elsevier B.V. All rights reserved

    Variability of radioiodine measurements in the thyroid

    Get PDF
    Monte Carlo simulations were carried out to study the response of a thyroid monitor for measuring intake activities of 125I and 131I. The aim of the study was 3-fold: to cross-validate the Monte Carlo simulation programs, to study the response of the detector using different phantoms and to study the effects of anatomical variations. Simulations were performed using the Swiss reference phantom and several voxelised phantoms. Determining the position of the thyroid is crucial for an accurate determination of radiological risks. The detector response using the Swiss reference phantom was in fairly good agreement with the response obtained using adult voxelised phantoms for 131I, but should be revised for a better calibration for 125I and for any measurements taken on paediatric patient

    Use of dipicolinate-based complexes for producing ion-imprinted polystyrene resins for the extraction of yttrium-90 and heavy lanthanide cations

    Get PDF
    Highly selective separation of yttrium (and lanthanides) is of interest for the design of radiopharmaceuticals, and an efficient method based on the ion-imprinting concept is proposed here. The synthesis and structural, thermodynamic and photophysical characterization of complexes of trivalent yttrium and lanthanides with two new vinyl derivatives of dipicolinic acid, HL1 and L2, are described. The feasibility of using ion-imprinted resins for yttrium and lanthanide separation is demonstrated. The resins were obtained by copolymerization with styrene and divinylbenzene and subsequent acid treatment to remove the metal ion. High-resolution Eu luminescence experiments revealed that the geometry of the complexation sites is well preserved in the imprinted polymers. The ion-imprinted polymer based on HL1 proved to be particularly well adapted for yttrium extraction, having a sizeable capacity (8.9 +- 0.2 g/mg resin) and a fast rate of extraction (t1/2 = 1.7 min). In addition, lighter and heavier lanthanide ions are separated. Finally, the resin displays high selectivity for yttrium and lanthanide cations against alkali and alkaline earth metals. For instance, in a typical experiment, 10 mg of yttrium was extracted from 5 g of milk ash sample by 2 g of the resin. The good separation properties displayed by the resin based on HL1 open interesting perspectives for the production of highly pure 90Y and radiolanthanides for medical applications, and for trace analysis of these radiochemicals in food and in the environment

    Characterisation of the PSI whole body counter by radiographic imaging

    Get PDF
    A joint project between the Paul Scherrer Institut (PSI) and the Institute of Radiation Physics was initiated to characterise the PSI whole body counter in detail through measurements and Monte Carlo simulation. Accurate knowledge of the detector geometry is essential for reliable simulations of human body phantoms filled with known activity concentrations. Unfortunately, the technical drawings provided by the manufacturer are often not detailed enough and sometimes the specifications do not agree with the actual set-up. Therefore, the exact detector geometry and the position of the detector crystal inside the housing were determined through radiographic images. X-rays were used to analyse the structure of the detector, and 60Co radiography was employed to measure the core of the germanium crystal. Moreover, the precise axial alignment of the detector within its housing was determined through a series of radiographic images with different incident angles. The hence obtained information enables us to optimise the Monte Carlo geometry model and to perform much more accurate and reliable simulation
    corecore