194 research outputs found

    Randomized comparison of ultrasonic aspiration versus conventional electrocautery for dissection of the human internal thoracic artery

    Get PDF
    AbstractThe most common technique currently employed to harvest the internal thoracic artery for coronary artery bypass grafting is conventional electrocautery. This study compared an alternative method, electrocautery with an ultrasonic aspirator, for harvesting the internal thoracic artery. Patients were randomly assigned to one of six experimental groups (conventional electrocautery, ultrasonic aspirator at settings of 60%, 80%, and 100% power output, and ultrasonic aspirator in 100% CAVI-Pulse modes 1 and 3). Ring segments of internal thoracic artery were studied in an organ bath. Contraction responses were elicited with 123 mmol/L potassium physiologic salt solution, KPSS, KPSS solution containing noradrenaline, and a cumulative noradrenaline dose-contraction curve. Relaxation studies were performed with the vasodilators acetylcholine, bradykinin, and sodium nitroprusside. Forty percent of the electrocauterized vessels were traumatized or damaged and failed to respond to contractile stimuli, whereas only 10% of the vessels in ultrasonic aspirator groups 60%, 80%, and 100% failed to respond. All vessels in the group harvested by ultrasonic aspirator in 100% CAVI-Pulse mode 1 responded, whereas 20% of the vessels in the group harvested by ultrasonic aspirator in 100% CAVI-Pulse mode 3 failed to respond. All settings of electrocautery with an ultrasonic aspirator produced a greater contractile response to KPSS and noradrenaline. Acetylcholine and sodium nitroprusside produced similar relaxations in all groups, but the bradykinin responses were significantly improved in all groups undergoing 100% electrocautery with an ultrasonic aspirator. These results suggest that 100% electrocautery with an ultrasonic aspirator, particularly in 100% CAVI-Pulse mode 1, resulted in less damage and trauma than conventional electrocautery during harvesting of the internal thoracic artery. (J T HORAC CARDIOVASC SURG 1996;111:1194-9

    Persistence in a Stationary Time-series

    Full text link
    We study the persistence in a class of continuous stochastic processes that are stationary only under integer shifts of time. We show that under certain conditions, the persistence of such a continuous process reduces to the persistence of a corresponding discrete sequence obtained from the measurement of the process only at integer times. We then construct a specific sequence for which the persistence can be computed even though the sequence is non-Markovian. We show that this may be considered as a limiting case of persistence in the diffusion process on a hierarchical lattice.Comment: 8 pages revte

    Existence and stability of viscoelastic shock profiles

    Full text link
    We investigate existence and stability of viscoelastic shock profiles for a class of planar models including the incompressible shear case studied by Antman and Malek-Madani. We establish that the resulting equations fall into the class of symmetrizable hyperbolic--parabolic systems, hence spectral stability implies linearized and nonlinear stability with sharp rates of decay. The new contributions are treatment of the compressible case, formulation of a rigorous nonlinear stability theory, including verification of stability of small-amplitude Lax shocks, and the systematic incorporation in our investigations of numerical Evans function computations determining stability of large-amplitude and or nonclassical type shock profiles.Comment: 43 pages, 12 figure

    Nutrient deficiencies in apple plants (Pyrus malus L.)

    Get PDF
    O ensaio foi conduzido com macieiras 'Ohio Beauty' com 1 ano, cultivadas em vaso para se verificar sintomas e níveis de deficiências de N, P, K, Ca, Mg, S e B. Conclui - se que: os níveis de nutrientes em folhas sadias e com sintomas de deficiência são: N -2,22 e 1,53%, P - 0,17 e 0,05%; K - 1,32 e 0,22%, Ca - 0,9¹* e 0,52%, Mg - 0,37 60,06%, S - 0,18 e 0,08%, B - 62 e 2k ppm. Os níveis de deficiência em folhas,a fome oculta" são: N - 1,74%, P - 0,07%, K - 0,30%, Ca - 0,65%, Mg - 0,09%, S - 0,09%, B-33ppm.A trial was carried out with one year old 'Ohio Beauty apples (grafted on 'Doucin'), grown on sand cu1ture, receining nutrient solutions lacking the following nutrients at the time: N, P, K, Ca, Mg, S, and B. The main conclusions are as follows: as the adequate and inadequate levels from leaf analysis were, respectively: N -2.22 and 1.53%, P - 0,17 and 0.05%, K - 1.32 and 0.33%; Ca -0.9.4 and 0.52%, Mg - 0.37 and 0.06%; S -0.18 and 0.08%; B -62 and 2k ppm

    Large-scale periodicity in the distribution of QSO absorption-line systems

    Full text link
    The spatial-temporal distribution of absorption-line systems (ALSs) observed in QSO spectra within the cosmological redshift interval z = 0.0--4.3 is investigated on the base of our updated catalog of absorption systems. We consider so called metallic systems including basically lines of heavy elements. The sample of the data displays regular variations (with amplitudes ~ 15 -- 20%) in the z-distribution of ALSs as well as in the eta-distribution, where eta is a dimensionless line-of-sight comoving distance, relatively to smoother dependences. The eta-distribution reveals the periodicity with period Delta eta = 0.036 +/- 0.002, which corresponds to a spatial characteristic scale (108 +/- 6) h(-1) Mpc or (alternatively) a temporal interval (350 +/- 20) h(-1) Myr for the LambdaCDM cosmological model. We discuss a possibility of a spatial interpretation of the results treating the pattern obtained as a trace of an order imprinted on the galaxy clustering in the early Universe.Comment: AASTeX, 13 pages, with 9 figures, Accepted for publication in Astrophysics & Space Scienc

    The surface detector array of the Telescope Array experiment

    Get PDF
    The Telescope Array (TA) experiment, located in the western desert of Utah,USA, is designed for observation of extensive air showers from extremely high energy cosmic rays. The experiment has a surface detector array surrounded by three fluorescence detectors to enable simultaneous detection of shower particles at ground level and fluorescence photons along the shower track. The TA surface detectors and fluorescence detectors started full hybrid observation in March, 2008. In this article we describe the design and technical features of the TA surface detector.Comment: 32 pages, 17 figure

    New air fluorescence detectors employed in the Telescope Array experiment

    Full text link
    Since 2007, the Telescope Array (TA) experiment, based in Utah, USA, has been observing ultra high energy cosmic rays to understand their origins. The experiment involves a surface detector (SD) array and three fluorescence detector (FD) stations. FD stations, installed surrounding the SD array, measure the air fluorescence light emitted from extensive air showers (EASs) for precise determination of their energies and species. The detectors employed at one of the three FD stations were relocated from the High Resolution Fly's Eye experiment. At the other two stations, newly designed detectors were constructed for the TA experiment. An FD consists of a primary mirror and a camera equipped with photomultiplier tubes. To obtain the EAS parameters with high accuracies, understanding the FD optical characteristics is important. In this paper, we report the characteristics and installation of new FDs and the performances of the FD components. The results of the monitored mirror reflectance during the observation time are also described in this report.Comment: 44 pages, 23 figures, submitted to NIM-
    corecore