458 research outputs found

    Controlling Magnetic Anisotropy in a Zero-Dimensional S=1 Magnet Using Isotropic Cation Substitution

    Get PDF
    The [Zn_{1–x}_Ni-{x}(HF_{2})(pyz)_{2}]SbF_{6} (x = 0.2; pyz = pyrazine) solid solution exhibits a zero-field splitting (D) that is 22% larger [D = 16.2(2) K (11.3(2) cm^{–1})] than that observed in the x = 1 material [D = 13.3(1) K (9.2(1) cm^{–1)}]. The substantial change in D is accomplished by an anisotropic lattice expansion in the MN_{4} (M = Zn or Ni) plane, wherein the increased concentration of isotropic Zn(II) ions induces a nonlinear variation in M-F and M-N bond lengths. In this, we exploit the relative donor atom hardness, where M-F and M-N form strong ionic and weak coordinate covalent bonds, respectively, the latter being more sensitive to substitution of Ni by the slightly larger Zn(II) ion. In this way, we are able to tune the single-ion anisotropy of a magnetic lattice site by Zn-substitution on nearby sites. This effect has possible applications in the field of single-ion magnets and the design of other molecule-based magnetic systems

    Linear and nonlinear optical spectroscopy of a strongly-coupled microdisk-quantum dot system

    Full text link
    A fiber taper waveguide is used to perform direct optical spectroscopy of a microdisk-quantum-dot system, exciting the system through the photonic (light) channel rather than the excitonic (matter) channel. Strong coupling, the regime of coherent quantum interactions, is demonstrated through observation of vacuum Rabi splitting in the transmitted and reflected signals from the cavity. The fiber coupling method also allows the examination of the system's steady-state nonlinear properties, where saturation of the cavity-QD response is observed for less than one intracavity photon.Comment: adjusted references, added minor clarification

    Strong Interactions of Single Atoms and Photons near a Dielectric Boundary

    Get PDF
    Modern research in optical physics has achieved quantum control of strong interactions between a single atom and one photon within the setting of cavity quantum electrodynamics (cQED). However, to move beyond current proof-of-principle experiments involving one or two conventional optical cavities to more complex scalable systems that employ N >> 1 microscopic resonators requires the localization of individual atoms on distance scales < 100 nm from a resonator's surface. In this regime an atom can be strongly coupled to a single intracavity photon while at the same time experiencing significant radiative interactions with the dielectric boundaries of the resonator. Here, we report an initial step into this new regime of cQED by way of real-time detection and high-bandwidth feedback to select and monitor single Cesium atoms localized ~100 nm from the surface of a micro-toroidal optical resonator. We employ strong radiative interactions of atom and cavity field to probe atomic motion through the evanescent field of the resonator. Direct temporal and spectral measurements reveal both the significant role of Casimir-Polder attraction and the manifestly quantum nature of the atom-cavity dynamics. Our work sets the stage for trapping atoms near micro- and nano-scopic optical resonators for applications in quantum information science, including the creation of scalable quantum networks composed of many atom-cavity systems that coherently interact via coherent exchanges of single photons.Comment: 8 pages, 5 figures, Supplemental Information included as ancillary fil

    Attachment styles and personal growth following romantic breakups: The mediating roles of distress, rumination, and tendency to rebound

    Get PDF
    © 2013 Marshall et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.This article has been made available through the Brunel Open Access Publishing Fund.The purpose of this research was to examine the associations of attachment anxiety and avoidance with personal growth following relationship dissolution, and to test breakup distress, rumination, and tendency to rebound with new partners as mediators of these associations. Study 1 (N = 411) and Study 2 (N = 465) measured attachment style, breakup distress, and personal growth; Study 2 additionally measured ruminative reflection, brooding, and proclivity to rebound with new partners. Structural equation modelling revealed in both studies that anxiety was indirectly associated with greater personal growth through heightened breakup distress, whereas avoidance was indirectly associated with lower personal growth through inhibited breakup distress. Study 2 further showed that the positive association of breakup distress with personal growth was accounted for by enhanced reflection and brooding, and that anxious individuals’ greater personal growth was also explained by their proclivity to rebound. These findings suggest that anxious individuals’ hyperactivated breakup distress may act as a catalyst for personal growth by promoting the cognitive processing of breakup-related thoughts and emotions, whereas avoidant individuals’ deactivated distress may inhibit personal growth by suppressing this cognitive work

    Targeting breast cancer stem cells: fishing season open!

    Get PDF
    Studies describing the tumor as a hierarchically organized cell population have changed the classical oncogenesis view and propose new therapeutic strategies. Cancer stem cells (CSCs) are thought to sustain tumor initiation/maintenance, therapy resistance, and systemic metastases. Targeting this tumor cell population is crucial to achieve a true cancer cure. A large research effort is now aiming to develop drugs targeting CSCs, based either on a priori understanding of key pathways regulating CSC biology or on high-throughput screening to identify novel targets and compounds

    Characteristics of patients initiating raloxifene compared to those initiating bisphosphonates

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Both raloxifene and bisphosphonates are indicated for the prevention and treatment of postmenopausal osteoporosis, however these medications have different efficacy and safety profiles. It is plausible that physicians would prescribe these agents to optimize the benefit/risk profile for individual patients. The objective of this study was to compare demographic and clinical characteristics of patients initiating raloxifene with those of patients initiating bisphosphonates for the prevention and treatment of osteoporosis.</p> <p>Methods</p> <p>This study was conducted using a retrospective cohort design. Female beneficiaries (45 years and older) with at least one claim for raloxifene or a bisphosphonate in 2003 through 2005 and continuous enrollment in the previous 12 months and subsequent 6 months were identified using a collection of large national commercial, Medicare supplemental, and Medicaid administrative claims databases (MarketScan<sup>®</sup>). Patients were divided into two cohorts, a combined commercial/Medicare cohort and a Medicaid cohort. Within each cohort, characteristics (demographic, clinical, and resource utilization) of patients initiating raloxifene were compared to those of patients initiating bisphosphonate therapy. Group comparisons were made using chi-square tests for proportions of categorical measures and Wilcoxon rank-sum tests for continuous variables. Logistic regression was used to simultaneously examine factors independently associated with initiation of raloxifene versus a bisphosphonate.</p> <p>Results</p> <p>Within both the commercial/Medicare and Medicaid cohorts, raloxifene patients were younger, had fewer comorbid conditions, and fewer pre-existing fractures than bisphosphonate patients. Raloxifene patients in both cohorts were less likely to have had a bone mineral density (BMD) screening in the previous year than were bisphosphonate patients, and were also more likely to have used estrogen or estrogen/progestin therapy in the previous 12 months. These differences remained statistically significant in the multivariate model.</p> <p>Conclusion</p> <p>In this sample of patients enrolled in commercial, Medicare, and Medicaid plans, patients who initiated raloxifene treatment differed from those initiating bisphosphonates. Raloxifene patients were younger, had better overall health status and appeared to be less likely to have risk factors for new osteoporotic fractures than bisphosphonate patients. Differences in the clinical profiles of these agents may impact prescribing decisions. Investigators using observational data to make comparisons of treatment outcomes associated with these medications should take these important differences in patient characteristics into consideration.</p

    Avaliação das técnicas de massagem e ordenha no tratamento do ingurgitamento mamário por termografia

    Get PDF
    OBJETIVO: evaluar los métodos de masaje y bombeo en el tratamiento de la congestión mamaria posparto a través de la termografía. MÉTODO: el estudio se realizó en el Banco de Leche Humana de un hospital en Curitiba, Brasil. Se seleccionaron al azar 16 mujeres en periodo de lactancia con congestión con clasificación lobar, ampular y glandular, moderada e intensa. Se compararon los patrones diferenciales de temperatura, antes y después del tratamiento por medio de masaje y bombeo. RESULTADOS: se encontró un degradado negativo de 0,3°C de temperatura entre el pre y post-tratamiento en el grupo experimental. Las mamas con intensa congestión eran 0,7°C más caliente en comparación a aquellos con congestión moderada. CONCLUSIÓN: el masaje y el bombeo electromecánico fueron superiores a los métodos manuales cuando se evaluaron por termografía. REBEC: U1111-1136-9027.OBJETIVO: avaliar técnicas de massagem e ordenha no tratamento do ingurgitamento mamário puerperal, por meio da termografia. MÉTODO: a pesquisa foi realizada no Banco de Leite Humano de um hospital de Curitiba, Brasil. Selecionaram-se, aleatoriamente, 16 lactantes com ingurgitamento com classificação lobar, ampolar e glandular moderado e intenso. Compararam-se os padrões diferenciais de temperatura, antes e após o tratamento realizado, por meio de massagem e ordenha. RESULTADOS: constatou-se um gradiente negativo de 0,3ºC de temperatura entre o pré e o pós-tratamento no grupo experimental. Mamas com ingurgitamento intenso foram 0,7ºC mais quentes quando comparadas com ingurgitamento moderado. CONCLUSÃO: a massagem e ordenha eletromecânicas são superiores às manuais, quando avaliadas por termografia. REBEC: U1111-1136-9027.OBJECTIVE: to evaluate techniques of massage and pumping in the treatment of postpartum breast engorgement through thermography. METHOD: the study was conducted in the Human Milk Bank of a hospital in Curitiba, Brazil. We randomly selected 16 lactating women with engorgement with the classification lobar, ampullary and glandular, moderate and intense. We compared the differential patterns of temperature, before and after the treatment by means of massage and pumping. RESULTS: we found a negative gradient of 0.3°C of temperature between the pre- and post-treatment in the experimental group. Breasts with intense engorgement were 0.7°C warmer when compared with moderate engorgement. CONCLUSION: massage and electromechanical pumping were superior to manual methods when evaluated by thermography. REBEC: U1111-1136-9027

    Markers of subtypes in inflammatory breast cancer studied by immunohistochemistry: Prominent expression of P-cadherin

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Inflammatory breast cancer (IBC) is a distinct and aggressive form of locally-advanced breast cancer with high metastatic potential. In Tunisia, IBC is associated with a high death rate. Among the major molecular subtypes, basal breast carcinomas are poorly differentiated, have metastatic potential and poor prognosis, but respond relatively well to chemotherapy. The aim of this study was to determine the distribution of molecular subtypes in IBC and identify factors that may explain the poor prognosis of IBC.</p> <p>Methods</p> <p>To determine breast cancer subtypes we studied by immunohistochemistry the expression of 12 proteins in a series of 91 Tunisian IBC and 541 non-IBC deposited in tissue microarrays.</p> <p>Results</p> <p>We considered infiltrating ductal cases only. We found 33.8% of basal cases in IBC vs 15.9% in non-IBC (p < 0.001), 33.3% of ERBB2-overexpressing cases in IBC vs 14.5% in non-IBC (p < 0.001), and 29.3% of luminal cases in IBC vs 59.9% in non-IBC (p < 0.001). The most differentially-expressed protein between IBCs and non-IBCs was P-cadherin. P-cadherin expression was found in 75.9% of all IBC vs 48.2% of all non-IBC (p < 0.001), 95% of IBC vs 69% of non-IBC (p = 0.02) in basal cases, and 82% of IBC vs 43% of non-IBC (p < 0.001) in luminal cases. Logistic regression determined that the most discriminating markers between IBCs and non-IBCs were P-cadherin (OR = 4.9, p = 0.0019) MIB1 (OR = 3.6, p = 0.001), CK14 (OR = 2.7, p = 0.02), and ERBB2 (OR = 2.3, p = 0.06).</p> <p>Conclusion</p> <p>Tunisian IBCs are characterized by frequent basal and ERBB2 phenotypes. Surprisingly, luminal IBC also express the basal marker P-cadherin. This profile suggests a specificity that needs further investigation.</p

    Dioxin Induces Genomic Instability in Mouse Embryonic Fibroblasts

    Get PDF
    Ionizing radiation and certain other exposures have been shown to induce genomic instability (GI), i.e., delayed genetic damage observed many cell generations later in the progeny of the exposed cells. The aim of this study was to investigate induction of GI by a nongenotoxic carcinogen, 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). Mouse embryonic fibroblasts (C3H10T1/2) were exposed to 1, 10 or 100 nM TCDD for 2 days. Micronuclei (MN) and expression of selected cancer-related genes were assayed both immediately and at a delayed point in time (8 days). For comparison, similar experiments were done with cadmium, a known genotoxic agent. TCDD treatment induced an elevated frequency of MN at 8 days, but not directly after the exposure. TCDD-induced alterations in gene expression were also mostly delayed, with more changes observed at 8 days than at 2 days. Exposure to cadmium produced an opposite pattern of responses, with pronounced effects immediately after exposure but no increase in MN and few gene expression changes at 8 days. Although all responses to TCDD alone were delayed, menadione-induced DNA damage (measured by the Comet assay), was found to be increased directly after a 2-day TCDD exposure, indicating that the stability of the genome was compromised already at this time point. The results suggested a flat dose-response relationship consistent with dose-response data reported for radiation-induced GI. These findings indicate that TCDD, although not directly genotoxic, induces GI, which is associated with impaired DNA damage response

    Strongly interacting polaritons in coupled arrays of cavities

    Get PDF
    Observing quantum phenomena in strongly correlated many-particle systems is difficult because of the short length- and timescales involved. Exerting control over the state of individual elements within such a system is even more so, and represents a hurdle in the realization of quantum computing devices. Substantial progress has been achieved with arrays of Josephson junctions and cold atoms in optical lattices, where detailed control over collective properties is feasible, but addressing individual sites remains a challenge. Here we show that a system of polaritons held in an array of resonant optical cavities—which could be realized using photonic crystals or toroidal microresonators—can form a strongly interacting many-body system showing quantum phase transitions, where individual particles can be controlled and measured. The system also offers the possibility to generate attractive on-site potentials yielding highly entangled states and a phase with particles much more delocalized than in superfluids
    • …
    corecore