526 research outputs found

    In vitro Release of Eosinophil Proteins in Allergic and Atopic Dermatitis Patients

    Get PDF
    To investigate whether eosinophils are stimulated in vivo or have acquired an increased susceptibility to stimuli from the coagulation cascade, the release of eosinophil proteins was compared for three groups of donors with different levels of serum IgE. (1) with atopic dermatitis (s-IgE > 5000 IU/ml, n = 11); (2) with inhalant allergy (200 < s-IgE < 2 000 IU/ml, n = 10); and (3) non-allergic (s- IgE < 100 IU/ml, n = 10). The levels of eosinophil cationic protein and eosinophil protein X (ECP, EPX) were determined in serum (clotting time = 2.0 h) and plasma. Serum and plasma ECP in normal donors demonstrated large intra-personal variations (C.V. 50–80%), but serum-ECP (mean 8.1 ng/ml) was clearly distinguishable from plasma ECP (mean 1.0 ng/ml) by a factor of 8 (range: 5.6–11.6). The ECP released during clotting was markedly increased in the atopic dermatitis group (serum:plasma ratio 13.5, p < 0.003) compared with the other groups (6.7 and 5.6). EPX, having a higher plasma level, demonstrated a less pronounced release (serum: plasma ratios 2.0, 1.7 and 1.4), with no statistical difference between donor groups. Considering all donors together the levels of ECP and EPX in plasma and in serum were correlated to the number of eosinophils (coefficients of correlation 0.54-0.58, p < 0.002)

    Collective Thomson scattering model for arbitrarily drifting bi-Maxwellian velocity distributions

    Get PDF
    In this paper we derive the equations of collective Thomson scattering (CTS) for an arbitrarily drifting magnetized plasma described by a bi-Maxwellian distribution. The model allows the treatment of anisotropic plasma with different parallel and perpendicular temperatures (with respect to the magnetic field) as well as parallel and perpendicular plasma drift. As could be expected, parallel observation directions are most sensitive to the parallel temperature and drift, whereas perpendicular observation directions are most sensitive to the perpendicular temperature and the perpendicular drift along the observation direction. The perpendicular drift can be related to the radial electric field. Measurements with a spectral resolution better than 0.5 MHz are necessary for the inference of the radial electric field. This spectral resolution and the required scattering geometry are attainable with the current setup of the CTS diagnostic on Wendelstein 7-X

    Switching between dynamic states in intermediate-length Josephson junctions

    Get PDF
    The appearance of zero-field steps (ZFS’s) in the current-voltage characteristics of intermediate-length overlap-geometry Josephson tunnel junctions described by a perturbed sine-Gordon equation (PSGE) is associated with the growth of parametrically excited instabilities of the McCumber background curve (MCB). A linear stability analysis of a McCumber solution of the PSGE in the asymptotic linear region of the MCB and in the absence of magnetic field yields a Hill’s equation which predicts how the number, locations, and widths of the instability regions depend on the junction parameters. A numerical integration of the PSGE in terms of truncated series of time-dependent Fourier spatial modes verifies that the parametrically excited instabilities of the MCB evolve into the fluxon oscillations characteristic of the ZFS’s. An approximate analysis of the Fourier mode equations in the presence of a small magnetic field yields a field-dependent Hill’s equation which predicts that the major effect of such a field is to reduce the widths of the instability regions. Experimental measurements on Nb-NbxOy-Pb junctions of intermediate length, performed at different operating temperatures in order to vary the junction parameters and for various magnetic field values, verify the physical existence of switching from the MCB to the ZFS’s. Good qualitative, and in many cases quantitative, agreement between analytic, numerical, and experimental results is obtained

    TFTR 60 GHz alpha particle collective Thomson scattering diagnostic

    Get PDF
    A 60 GHz gyrotron collective Thomson Scattering alpha particle diagnostic has been implemented for the D-T period on TFM. Gyrotron power of 0.1-1 kW in pulses of up to 1 second can be launched in X-mode. Efficient corrugated waveguides are used with antennaes and vacuum windows of the TFTR Microwave Scattering system. A multichannel synchronous detector receiver system and spectrum analyzer acquire the scattered signals. A 200 Megasample/sec digitizer is used to resolve fine structure in the frequency spectrum. By scattering nearly perpendicular to the magnetic field, this experiment will take advantage of an enhancement of the scattered signal which results from the interaction of the alpha particles with plasma resonances in the lower hybrid frequency range. Significant enhancements are expected, which will make these measurements possible with gyrotron power less than 1 kW, while maintaining an acceptable signal to noise ratio. We hope to extract alpha particle density and velocity distribution functions from the data. The D and T fuel densities and temperatures may also be obtainable by measurement of the respective ion cyclotron harmonic frequencies
    • …
    corecore