143 research outputs found

    Influence of surface chemistry and morphology of nanoparticles on protein corona formation

    Get PDF
    Nanomaterials offer promising solutions as drug delivery systems and imaging agents in response to the demand for better therapeutics and diagnostics. However, the limited understanding of the interaction between nanoparticles and biological entities is currently hampering the development of new systems and their applications in clinical settings. Proteins and lipids in biological fluids are known to complex with nanoparticles to form a “biomolecular corona”. This has been shown to affect particles' morphology and behavior in biological systems and their interactions with cells. Hence, understanding how nanomaterials' physicochemical properties affect the formation and composition of this biocorona is a crucial step. This work evaluates existing literature on how morphology (size and shape), and surface chemistry (charge and hydrophobicity) of nanoparticles influence the formation of protein corona. The latest evidence suggest that although surface charge promotes the interaction with proteins and lipids, surface chemistry plays a leading role in determining the affinity of the nanoparticle for biomolecules and, ultimately, the composition of the corona. More recently the study of additional nanoparticles' properties like shape and surface chirality have demonstrated a significant effect on protein corona architecture, providing new tools to tailor biomolecular corona formation. This article is categorized under: Therapeutic Approaches and Drug Discovery > Emerging Technologies. Toxicology and Regulatory Issues in Nanomedicine > Toxicology of Nanomaterials

    The fetal profile line:a proposal for a sonographic reference line to classify forehead and mandible anomalies in the second and third trimester

    Get PDF
    Objectives To test the fetal profile (FP) line, defined as the line that passes through the anterior border of the mandible and the nasion, as a reference line for forehead and mandible anomalies. Methods Volumes of 248 normal and 24 pathological fetuses (1636 and 1937?weeks gestation, respectively) were analysed retrospectively. When the FP line passes anteriorly, across or posteriorly to the frontal bone, this was defined as negative, zero or positive, respectively. When the FP line was positive the distance (F distance) between the FP line and the frontal bone was measured. Results No cases with a negative FP line were found in the normal fetuses. Before 27?weeks gestation the FP line was always zero except in one case. After 27?weeks gestation the FP line was positive in up to 25% (F distance (mean, range): 2.8, 2.13.6?mm). The FP line correctly identified 13 cases with retrognathia, 5 cases with frontal bossing and 3 cases with a sloping forehead. Conclusion Although large prospective studies are needed, the FP line may be a useful tool to detect second trimester profile anomalies such as retrognathia, sloping forehead and frontal bossing with the possibility of quantifying the latter. (c) 2012 John Wiley & Sons, Ltd

    Intrapericardial Extralobar Pulmonary Sequestration Presenting as a Prenatal Intrathoracic Mass

    Get PDF
    An intrathoracic mass, which persisted during the remaining pregnancy, was first seen during routine ultrasound examination performed at 20 weeks gestation. After birth, the child was asymptomatic. Echocardiography showed the mass to be located intrapericardially. The mass was electively resected via sternotomy 3 weeks after the birth. Microscopic examination showed normal lung tissue surrounded by pleura corresponding to the diagnosis of extralobar pulmonary sequestration. To the authors’ knowledge, this is the earliest described detection of such a lesion. Furthermore, this article reports the unique finding of a feeding vessel from the right pulmonary artery

    Nuchal translucency of 3.0-3.4 mm an indication for NIPT or microarray? Cohort analysis and literature review

    Get PDF
    Introduction: Currently fetal nuchal translucency (NT) ≥3.5 mm is an indication for invasive testing often followed by chromosomal microarray. The aim of this study was to assess the risks for chromosomal aberrations in fetuses with an NT 3.0-3.4 mm, to determine whether invasive prenatal testing would be relevant in these cases and to assess the residual risks in fetuses with normal non-invasive prenatal test (NIPT) results. Material and methods: A retrospective study and meta-analysis of literature cases with NT between 3.0 and 3.4 mm and 2 cohorts of pregnant women referred for invasive testing and chromosomal microarray was performed: Rotterdam region (with a risk >1:200 and NT between 3.0 and 3.4 mm) tested in the period July 2012 to June 2019 and Central Denmark region (with a risk >1:300 and NT between 3.0 and 3.4 mm) tested between September 2015 and December 2018. Results: A total of 522 fetuses were referred for invasive testing and chromosomal microarray. Meta-analysis indicated that in 1:7.4 (13.5% [95% CI 8.2%-21.5%]) fetuses a chromosomal aberration was diagnosed. Of these aberrant cases, 47/68 (69%) involved trisomy 21, 18, and 13 and would potentially be detected by all NIPT approaches. The residual risk for missing a (sub)microscopic chromosome aberration depends on the NIPT approach and is highest if NIPT was performed only for common trisomies–1:21 (4.8% [95% CI 3.2%-7.3%]). However, it may be substantially lowered if a genome-wide 10-Mb resolution NIPT test was offered (~1:464). Conclusions: Based on these data, we suggest that the NT cut-off for invasive testing could be 3.0 mm (instead of 3.5 mm) because of the high risk of 1:7.4 for a chromosomal aberration. If women were offered NIPT first, there would be a significant diagnostic delay because all abnormal NIPT results need to be confirmed by diagnostic testing. If the woman had already received a normal NIPT result, the residual risk of 1:21 to 1:464 for chromosome aberrations other than common trisomies, dependent on the NIPT approach, should be raised. If a pregnant woman declines invasive testing, but still wants a test with a broader coverage of clinically significant conditions then the genome-wide >10-Mb resolution NIPT test, which detects most aberrations, could be proposed

    Seven Key Principles of Program and Project Success: A Best Practices Survey

    Get PDF
    The National Aeronautics and Space Administration (NASA) Organization Design Team (ODT), consisting of 20 seasoned program and project managers and systems engineers from a broad spectrum of the aerospace industry, academia, and government, was formed to support the Next Generation Launch Technology (NGLT) Program and the Constellation Systems Program. The purpose of the ODT was to investigate organizational factors that can lead to success or failure of complex government programs, and to identify tools and methods for the design, modeling, and analysis of new and more-efficient program and project organizations. The ODT conducted a series of workshops featuring invited lectures from seasoned program and project managers representing 25 significant technical programs spanning 50 years of experience. The result was the identification of seven key principles of program success that can be used to help design and operate future program organizations. This paper presents the success principles and examples of best practices that can significantly improve the design of program, project, and performing technical line organizations, the assessment of workforce needs and organization performance, and the execution of programs and projects

    Reduced right ventricular function on cardiovascular magnetic resonance imaging is associated with uteroplacental impairment in tetralogy of Fallot

    Get PDF
    Background: Maternal right ventricular (RV) dysfunction (measured by echocardiography) is associated with impaired uteroplacental circulation, however echocardiography has important limitations in the assessment of RV function. We therefore aimed to investigate the association of pre-pregnancy RV and left ventricular (LV) function measured by cardiovascular magnetic resonance with uteroplacental Doppler flow parameters in pregnant women with repaired Tetralogy of Fallot (ToF). Methods: Women with repaired ToF were examined, who had been enrolled in a prospective multicenter study of pregnant women with congenital heart disease. Clinical data and CMR evaluation before pregnancy were compared with uteroplacental Doppler parameters at 20 and 32 weeks gestation. In particular, pulsatility index (PI) of uterine and umbilical artery were studied. Results: We studied 31 women; mean age 30 years, operated at early age. Univariable analyses showed that reduced RV ejection fraction (RVEF; P = 0.037 and P = 0.001), higher RV end-systolic volume (P = 0.004) and higher LV end-diastolic and end-systolic volume (P = 0.001 and P = 0.003, respectively) were associated with higher uterine or umbilical artery PI. With multivariable analyses (corrected for maternal age and body mass index), reduced RVEF before pregnancy remained associated with higher umbilical artery PI at 32 weeks (P = 0.002). RVEF was lower in women with high PI compared to women with normal PI during pregnancy (44% vs. 53%, p = 0.022). LV ejection fraction was not associated with uterine or umbilical artery PI. Conclusions: Reduced RV function before pregnancy is associated with abnormal uteroplacental Doppler flow parameters. It could be postulated that reduced RV function on pre-pregnancy CMR (≤2 years) is a predisposing factor for impaired placental function in women with repaired ToF.</p

    Using three-dimensional ultrasound in predicting complex gastroschisis:A longitudinal, prospective, multicenter cohort study

    Get PDF
    Objective: To determine whether complex gastroschisis (ie, intestinal atresia, perforation, necrosis, or volvulus) can prenatally be distinguished from simple gastroschisis by fetal stomach volume and stomach-bladder distance, using three-dimensional (3D) ultrasound. Methods: This multicenter prospective cohort study was conducted in the Netherlands between 2010 and 2015. Of seven university medical centers, we included the four centers that performed longitudinal 3D ultrasound measurements at a regular basis. We calculated stomach volumes (n = 223) using Sonography-based Automated Volume Count. The shortest stomach-bladder distance (n = 241) was determined using multiplanar visualization of the volume datasets. We used linear mixed modelling to evaluate the effect of gestational age and type of gastroschisis (simple or complex) on fetal stomach volume and stomach-bladder distance. Results: We included 79 affected fetuses. Sixty-six (84%) had been assessed with 3D ultrasound at least once; 64 of these 66 were liveborn, nine (14%) had complex gastroschisis. With advancing gestational age, stomach volume significantly increased, and stomach-bladder distance decreased (both P <.001). The developmental changes did not differ significantly between fetuses with simple and complex gastroschisis, neither for fetal stomach volume (P =.85), nor for stomach bladder distance (P =.78). Conclusion: Fetal stomach volume and stomach-bladder distance, measured during pregnancy using 3D ultrasonography, do not predict complex gastroschisis

    Trial by Dutch laboratories for evaluation of non-invasive prenatal testing. Part I—clinical impact

    Get PDF
    Objective: To evaluate the clinical impact of nationwide implementation of genome-wide non-invasive prenatal testing (NIPT) in pregnancies at increased risk for fetal trisomies 21, 18 and 13 (TRIDENT study). Method: Women with elevated risk based on first trimester combined testing (FCT ≥ 1:200) or medical history, not advanced maternal age alone, were offered NIPT as contingent screening test, performed by Dutch University Medical laboratories. We analyzed uptake, test performance, redraw/failure rate, turn-around time and pregnancy outcome. Results: Between 1 April and 1 September 2014, 1413/23 232 (6%) women received a high-risk FCT result. Of these, 1211 (85.7%) chose NIPT. One hundred seventy-nine women had NIPT based on medical history. In total, 1386/1390 (99.7%) women received a result, 6 (0.4%) after redraw. Mean turn-around time was 14 days. Follow-up was available in 1376 (99.0%) pregnancies. NIPT correctly predicted 37/38 (97.4%) trisomies 21, 18 or 13 (29/30, 4/4 and 4/4 respectively); 5/1376 (0.4%) cases proved to be false positives: trisomies 21 (n = 2), 18 (n = 1) and 13 (n = 2). Estimated reduction in invasive testing was 62%. Conclusion: Introduction of NIPT in the Dutch National healthcare-funded Prenatal Screening Program resulted in high uptake and a vast reduction of invasive testing. Our study supports offering NIPT to pregnant women at increased risk for fetal trisomy. © 2016 The Authors. Prenatal Diagnosis published by John Wiley & Sons, Ltd. © 2016 The Authors. Prenatal Diagnosis published by John Wiley & Sons, Ltd
    corecore