790 research outputs found

    Tidal turbine blade load experiments for oscillatory motion

    Get PDF
    This paper presents blade root bending moment measurements of a horizontal-axis tidal turbine for planar oscillatory motion, conducted in a stationary water towing tank. By comparing the measurements with quasi-steady reconstructions for both single and multiple frequency oscillatory motion, the bending moment was shown to be sensitive to both frequency and amplitude, as well as to the mean tip-speed ratio. The unsteady loads associated with the separation of the flow and dynamic stall are shown to be of considerably greater importance than those which are already present for attached flow, such as added mass and dynamic inflow. A linear model fit to the unsteady bending moment also indicates that the inertia contribution is relatively small. For cases where attached flow exists over the majority of the load cycle, these reconstruction methods are likely to be sufficient to obtain a reasonable prediction of the root out-of-plane bending moment. However, turbines whose blades are likely to operate near stall are likely to require more complex models for accurate load predictions to mitigate the risk of fatigue failure

    Experimental investigation into the post-filling stage of the resin infusion process

    Get PDF
    International audienceThe resin infusion process has developed as a low-cost method to produce large composite parts in low to medium quantities. Although the process is conceptually simple, the effects of many of the processing parameters on the post-filling stage of the process are not well understood. Most manufacturers tend to develop their approach to infusion process through trial and error, and then adhere to their 'secret recipe' without knowledge of the effect of each parameter. This paper describes an experimental investigation of the controllable process parameters and their effect on the final laminate composition, by monitoring local fluid pressure and full field laminate thickness data through the filling and post-filling stages. From the understanding of the effect of each parameter, guidelines are drawn to help manufacturers to optimise their process. The effect of using a 'brake' between the part and the vent are evaluated, and the benefits of turning the inlet into a vent at the onset of post-filling are highlighted together with methods of gaining some control on the final laminate fibre volume fraction

    Kuiper Belt Object Occultations: Expected Rates, False Positives, and Survey Design

    Full text link
    A novel method of generating artificial scintillation noise is developed and used to evaluate occultation rates and false positive rates for surveys probing the Kuiper Belt with the method of serendipitous stellar occultations. A thorough examination of survey design shows that: (1) diffraction-dominated occultations are critically (Nyquist) sampled at a rate of 2 Fsu^{-1}, corresponding to 40 s^{-1} for objects at 40 AU, (2) occultation detection rates are maximized when targets are observed at solar opposition, (3) Main Belt Asteroids will produce occultations lightcurves identical to those of Kuiper Belt Objects if target stars are observed at solar elongations of: 116 deg < epsilon < 125 deg, or 131 deg < epsilon < 141 deg, and (4) genuine KBO occultations are likely to be so rare that a detection threshold of >7-8 sigma should be adopted to ensure that viable candidate events can be disentangled from false positives.Comment: Accepted AJ, 12 pages, 12 figure

    Simulation of the reinforcement compaction and resin flow during the complete resin infusion process

    Get PDF
    International audienceResin infusion (a.k.a. VARTM) is one of the LCM processes, for which liquid resin is drawn into dry reinforcements. Significant cavity thickness changes occur during processing, due to the flexibility of the vacuum bag used as one side of the tool, and the complex stress balance within the laminate. While the magnitude of thickness change is often small, the influence is significant on reinforcement properties. Changes in permeability during filling and post-filling have the potential to significantly affect the process. To simulate this behaviour, it is important to accurately model compaction and unloading of reinforcement in dry and wet states. A series of tests were completed to determine compaction behaviour of an isotropic glass fibre mat. From these tests several non-linear elastic compaction models have been determined, and applied within a resin infusion simulation which addresses pre-filling, filling and post-filling. This simulation was then used to assess different post-filling strategies

    Strategies to Use Nanoparticles to Generate CD4 and CD8 Regulatory T Cells for the Treatment of SLE and Other Autoimmune Diseases

    Get PDF
    Autoimmune diseases are disorders of immune regulation where the mechanisms responsible for self-tolerance break down and pathologic T cells overcome the protective effects of T regulatory cells (Tregs) that normally control them. The result can be the initiation of chronic inflammatory diseases. Systemic lupus erythematosus (SLE) and other autoimmune diseases are generally treated with pharmacologic or biological agents that have broad suppressive effects. These agents can halt disease progression, yet rarely cure while carrying serious adverse side effects. Recently, nanoparticles have been engineered to correct homeostatic regulatory defects and regenerate therapeutic antigen-specific Tregs. Some approaches have used nanoparticles targeted to antigen presenting cells to switch their support from pathogenic T cells to protective Tregs. Others have used nanoparticles targeted directly to T cells for the induction and expansion of CD4+ and CD8+ Tregs. Some of these T cell targeted nanoparticles have been formulated to act as tolerogenic artificial antigen presenting cells. This article discusses the properties of these various nanoparticle formulations and the strategies to use them in the treatment of autoimmune diseases. The restoration and maintenance of Treg predominance over effector cells should promote long-term autoimmune disease remission and ultimately prevent them in susceptible individuals

    Full field monitoring of the resin flow and laminate properties during the resin infusion process

    Get PDF
    International audienceThe resin infusion process (a.k.a. VARTM, SCRIMP) has developed as a low cost method for manufacturing large fibre reinforced plastic parts. This process still presents some challenges to industry with regards to reliability and repeatability, resulting in trial and error development being expensive and inefficient. This paper describes a fully instrumented resin infusion setup, providing preliminary experimental data acquired while varying influential parameters during the filling and post-filling stages. The laminate per-meability is a strong function of the fibre volume fraction which can be determined from the laminate thickness. To assess the variation of the volume fraction and permeability, full field thickness variations have been monitored using a digital speckle stereophotogrammetry system developed for this purpose. In-mould resin pressures, flow front progression, and incoming resin flow rate were also measured. A selection of four experiments is presented here for discussion

    The Joint European Compound Library:boosting precompetitive research

    Get PDF
    The Joint European Compound Library (JECL) is a new high-throughput screening collection aimed at driving precompetitive drug discovery and target validation. The JECL has been established with a core of over 321000 compounds from the proprietary collections of seven pharmaceutical companies and will expand to around 500000 compounds. Here, we analyse the physicochemical profile and chemical diversity of the core collection, showing that the collection is diverse and has a broad spectrum of predicted biological activity. We also describe a model for sharing compound information from multiple proprietary collections, enabling diversity and quality analysis without disclosing structures. The JECL is available for screening at no cost to European academic laboratories and SMEs through the IMI European Lead Factory (http://www.europeanleadfactory.eu/)
    corecore