    MATCH: a new industry-focused approach to medical device development

    Get PDF
    MATCH (Multidisciplinary Assessment of Technology Centre for Healthcare) is a new collaboration in the UK that aims to support the healthcare sector by creating methods to assess the value of medical devices from concept through to mature product. A major aim of MATCH is to encourage the inclusion of the user throughout the product lifecycle in order to achieve devices that truly meet the requirements of their users. A review of the published literature indicates that user requirements are mainly collected during the design and evaluation stage of the product lifecycle whilst other areas, including the concept stage, have less user involvement. Complementing the literature review is an in-depth consultation with the medical device industry, which has identified a number of barriers encountered by companies when attempting to capture user requirements. These will be addressed by a number of case study projects, performed in collaboration with our industrial partners, that will examine the application and utility of different approaches to collecting and analysing data on user requirements. MATCH is focused on providing advice to device developers on how to select and apply methods that have maximum theoretical strength, practical application, cost-effectiveness and likelihood of wide sector acceptance. Feedback will be sought in order to ensure that the needs of the diverse medical device sector are met

    Medical Device Development: the challenge for ergonomics

    Get PDF
    High quality, well designed medical devices are necessary to provide safe and effective clinical care for patients as well as to ensure the health and safety of professional and lay device users. Capturing the user requirements of users and incorporating these into design is an essential component of this. The field of ergonomics has an opportunity to assist, not only with this area, but also to encourage a more general consideration of the user during medical device development. A review of the literature on methods for assessing user requirements in engineering and ergonomics found that little published work exists on the ergonomics aspects of medical device development. In particular there is little advice available to developers on which issues to consider during design and development or recommendations for good practice in terms of the methods and approaches needed to capture the full range of user requirements. The Multidisciplinary Assessment of Technology Centre for Healthcare (MATCH) is a research collaboration that is working in conjunction with industrial collaborators to apply ergonomics methods to real case study projects with the ultimate aim of producing an industry-focused guide to applying ergonomics principles in medical device development

    Capturing User Requirements in Medical Device Development: The Role of Ergonomics

    Get PDF
    Measuring and fulfilling user requirements during medical device development will result in successful products that improve patient safety, improve device effectiveness and reduce product recalls and modifications. Medical device users are an extremely heterogeneous group and for any one device the users may include patients, their carers as well as various healthcare professionals. There are a number of factors that make capturing user requirements for medical device development challenging including the ethical and research governance involved with studying users as well as the inevitable time and financial constraints. Most ergonomics research methods have been developed in response to such practical constraints and a number of these have potential for medical device development. Some are suitable for specific points in the device cycle such as contextual inquiry and ethnography, others, such as usability tests and focus groups may be used throughout development. When designing user research there are a number of factors that may affect the quality of data collected including the sample of users studied, the use of proxies instead of real end-users and the context in which the research is performed. As different methods are effective in identifying different types of data, ideally more than one method should be used at each point in development, however financial and time factors may often constrain this

    Alert but less alarmed: a pooled analysis of terrorism threat perception in Australia

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Previous Australian research has highlighted disparities in community perceptions of the threat posed by terrorism. A study with a large sample size is needed to examine reported concerns and anticipated responses of community sub-groups and to determine their consistency with existing Australian and international findings.</p> <p>Methods</p> <p>Representative samples of New South Wales (NSW) adults completed terrorism perception questions as part of computer assisted telephone interviews (CATI) in 2007 (N = 2081) and 2010 (N = 2038). Responses were weighted against the NSW population. Data sets from the two surveys were pooled and multivariate multilevel analyses conducted to identify health and socio-demographic factors associated with higher perceived risk of terrorism and evacuation response intentions, and to examine changes over time.</p> <p>Results</p> <p>In comparison with 2007, Australians in 2010 were significantly more likely to believe that a terrorist attack would occur in Australia (Adjusted Odd Ratios (AOR) = 1.24, 95%CI:1.06-1.45) but felt less concerned that they would be directly affected by such an incident (AOR = 0.65, 95%CI:0.55-0.75). Higher perceived risk of terrorism and related changes in living were associated with middle age, female gender, lower education and higher reported psychological distress. Australians of migrant background reported significantly lower likelihood of terrorism (AOR = 0.52, 95%CI:0.39-0.70) but significantly higher concern that they would be personally affected by such an incident (AOR = 1.57, 95%CI:1.21-2.04) and having made changes in the way they live due to this threat (AOR = 2.47, 95%CI:1.88-3.25). Willingness to evacuate homes and public places in response to potential incidents increased significantly between 2007 and 2010 (AOR = 1.53, 95%CI:1.33-1.76).</p> <p>Conclusion</p> <p>While an increased proportion of Australians believe that the national threat of terrorism remains high, concern about being personally affected has moderated and may reflect habituation to this threat. Key sub-groups remain disproportionately concerned, notably those with lower education and migrant groups. The dissonance observed in findings relating to Australians of migrant background appears to reflect wider socio-cultural concerns associated with this issue. Disparities in community concerns regarding terrorism-related threat require active policy consideration and specific initiatives to reduce the vulnerabilities of known risk groups, particularly in the aftermath of future incidents.</p

    Designing out Medical Error: An Interdisciplinary Approach to the Design of Healthcare Equipment

    Get PDF
    Medical error is an internationally recognised problem, with major financial and human costs (Gray; 2003, de Vries; et.al. 2008). The design of hospital equipment, devices and environments can contribute to the problem. Clinical staff often have to cope with confusing interfaces and equipment, making their tasks difficult and potentially dangerous. There are calls to rethink the approach to design in healthcare. Design should acknowledge the real world issues users face in the hospital environment. A collaborative approach is required to understand these issues, (Karsh & Scanlon, 2007). This paper outlines the methodologies used in two interdisciplinary case study projects, revealing the importance of a clear set of working methods and detailing the approach taken at each point. The resulting designs aim to better support healthcare processes, reducing the instance of medical error and ultimately saving lives

    Alternative splicing: the pledge, the turn, and the prestige

    Get PDF

    MATCH: a new industry-focused approach to medical device development

    Get PDF
    MATCH (Multidisciplinary Assessment of Technology Centre for Healthcare) is a new collaboration in the UK that aims to support the healthcare sector by creating methods to assess the value of medical devices from concept through to mature product. A major aim of MATCH is to encourage the inclusion of the user throughout the product lifecycle in order to achieve devices that truly meet the requirements of their users. A review of the published literature indicates that user requirements are mainly collected during the design and evaluation stage of the product lifecycle whilst other areas, including the concept stage, have less user involvement. Complementing the literature review is an in-depth consultation with the medical device industry, which has identified a number of barriers encountered by companies when attempting to capture user requirements. These will be addressed by a number of case study projects, performed in collaboration with our industrial partners, that will examine the application and utility of different approaches to collecting and analysing data on user requirements. MATCH is focused on providing advice to device developers on how to select and apply methods that have maximum theoretical strength, practical application, cost-effectiveness and likelihood of wide sector acceptance. Feedback will be sought in order to ensure that the needs of the diverse medical device sector are met

    IL-7 regulates basal homeostatic proliferation of antiviral CD4(+)T cell memory

    No full text
    Heightened protection from infectious disease as conferred by vaccination or pathogen exposure relies on the effective generation and preservation of specific immunological memory. T cells are irreducibly required for the control of most viral infections, and maintenance of CD8(+)T cell memory is regulated by at least two cytokines, IL-7 and IL-15, which support survival (IL-7, IL-15) and basal homeostatic proliferation (IL-15) of specific CD8(+) memory T cells (T(M)). In contrast, the factors governing the homeostasis of pathogen-specific CD4(+)T(M) remain at present unknown. Here, we used a physiologic in vivo model system for viral infection to delineate homeostatic features and mechanisms of antiviral CD4(+)T(M) preservation in direct juxtaposition to CD8(+)T cell memory. Basal homeostatic proliferation is comparable between specific CD4(+) and CD8(+)T(M) and independent of immunodominant determinants and functional avidities but regulated in a tissue-specific fashion. IL-7, identified as the dominant cytokine, and IL-15, an accessory cytokine, regulate basal homeostatic proliferation and survival of antiviral CD4(+)T(M). Interestingly, a role for these cytokines in regulation of CD4(+)T cell memory is not readily discernible in the generic “memory-phenotype” population, apparently a consequence of its heterogeneous composition. We also describe a prominent, nonredundant role for IL-7 in supporting basal homeostatic proliferation of CD8(+)T(M). We propose that homeostatic control of antiviral CD4(+) and CD8(+) T cell memory is fundamentally similar and characterized by quantitative, rather than qualitative, differences
    corecore