3,717 research outputs found

    EPR and pulsed ENDOR study of intermediates from reactions of aromatic azides with group 13 metal trichlorides

    Get PDF
    The reactions of group 13 metal trichlorides with aromatic azides were examined by CW EPR and pulsed ENDOR spectroscopies. Complex EPR spectra were obtained from reactions of aluminium, gallium and indium trichlorides with phenyl azides containing a variety of substituents. Analysis of the spectra showed that 4-methoxy-, 3-methoxy- and 2-methoxyphenyl azides all gave ‘dimer’ radical cations [ArNHC6H4NH2]+• and trimers [ArNHC6H4NHC6H4NH2]+• followed by polymers. 4-Azidobenzonitrile, with its electron-withdrawing substituent, did not react. In general the aromatic azides appeared to react most rapidly with AlCl3 but this reagent tended to generate much polymer. InCl3 was the least reactive group 13 halide. DFT computations of the radical cations provided corroborating evidence and suggested that the unpaired electrons were accommodated in extensive π-delocalised orbitals. A mechanism to account for the reductive conversion of aromatic azides to the corresponding anilines and thence to the dimers and trimers is proposedPublisher PDFPeer reviewe

    An ultra-light cylindrical GEM detector as inner tracker at KLOE-2

    Get PDF
    Abstract We are developing a low-mass, fully cylindrical and dead-zone-free GEM detector as inner tracker for the KLOE experiment upgrade at the DA Φ NE Φ factory. The inner tracker will be composed of five concentric layers of cylindrical triple-GEM detectors (C-GEM), completely realized with very thin polyimide foils. The final result is a very light detector: only 0.2% of X 0 per layer inside the active area. We successfully built and tested with an X-ray gun a small-size prototype operated in current mode with an Ar/CO 2 = 70 / 30 gas mixture. The very positive results obtained with the prototype open the way for a completely new and competitive category of ultra-light fully sensitive vertex detectors for high-energy physics experiments

    COVID-19 dentistry-related aspects: a literature overview

    Get PDF
    A new coronavirus (Sars-CoV-2) was detected in China at the end of 2019 and has since caused a worldwide pandemic. This virus is responsible for an acute respiratory syndrome (COVID-19), distinguished by a potentially lethal interstitial bilateral pneumonia. Because Sars-CoV-2 is highly infective through airborne contamination, the high infection risk in the dental environment is a serious problem for both professional practitioners and patients. This literature overview provides a description of the clinical aspects of COVID-19 and its transmission, while supplying valuable information regarding protection and prevention measures

    Conservative treatment of unicystic mural ameloblastoma

    Get PDF
    Mural ameloblastoma is a subtype of Unicystic Ameloblastoma characterised by the expansion or infiltration of tumour nodules into the fibrous wall of the cyst. The behaviour of this subtype is highly aggressive, with a risk of recurrence comparable with that of Conventional Ameloblastoma. Consequently, the preferred treatment for Unicystic mural Ameloblastom is broad resection of the tumour. In this case report we describe the successful conservative treatment of a Unicystic mural Ameloblastom associated with an impacted tooth. The conservative treatment consinsted in a initial marsupialization followed by the enucleation of the lesion performed with a lateral corticotomy to create a \u201cbone door\u201d and the relocation of the \u201cbone door\u201d using microplates and titanium screws. Our conservative approach preserved the integrity of the inferior alveolar nerve as well as mandibular functionality and resulted in a good aesthetic outcome. Due to the behaviour of this lesion, a strict follow up is mandatory. In our experience, follow-up is conducted as long as possible regardless of the surgical treatment. This protocol includes Cone Beam CT performed 1 year after surgery and panoramic radiology (OPG) once a year until 5 years after surgery. OPG is then repeated every 3 years in patients with Unicystic Ameloblastoma and every 2 years in those with Conventional Ameloblastoma or ameloblastoma with mural invasion. Suspected recurrence should be evaluated by CBCT

    High-resolution tracking in a GEM-Emulsion detector

    Full text link
    SHiP (Search for Hidden Particles) is a beam dump experiment proposed at the CERN SPS aiming at the observation of long lived particles very weakly coupled with ordinary matter mostly produced in the decay of charmed hadrons. The beam dump facility of SHiP is also a copious factory of neutrinos of all three kinds and therefore a dedicated neutrino detector is foreseen in the SHiP apparatus. The neutrino detector exploits the Emulsion Cloud Chamber technique with a modular structure, alternating walls of target units and planes of electronic detectors providing the time stamp to the event. GEM detectors are one of the possible choices for this task. This paper reports the results of the first exposure to a muon beam at CERN of a new hybrid chamber, obtained by coupling a GEM chamber and an emulsion detector. Thanks to the micrometric accuracy of the emulsion detector, the position resolution of the GEM chamber as a function of the particle inclination was evaluated in two configurations, with and without the magnetic fiel

    Status of the Cylindical-GEM project for the KLOE-2 Inner Tracker

    Full text link
    The status of the R&D on the Cylindrical-GEM (CGEM) detector foreseen as Inner Tracker for KLOE-2, the upgrade of the KLOE experiment at the DAFNE phi-factory, will be presented. The R&D includes several activities: i) the construction and complete characterization of the full-size CGEM prototype, equipped with 650 microns pitch 1-D longitudinal strips; ii) the study of the 2-D readout with XV patterned strips and operation in magnetic field (up to 1.5T), performed with small planar prototypes in a dedicated test at the H4-SPS beam facility; iii) the characterization of the single-mask GEM technology for the realization of large-area GEM foils.Comment: 4 pages, 10 figures, Presented at Vienna Conference on Instrumentation (Feb 15-20, 2010, Vienna, Austria). Submitted to the Proceeding

    Production and performance of LHCb triple-GEM detectors equipped with the dedicated CARDIAC-GEM front-end electronics

    Get PDF
    The production of the triple-GEM detectors for the innermost region of the first muon station of the LHCb experiment has started in February 2006, and is foreseen to be completed by the end of July. The final design of the detector and the construction procedure and tools, as well as the quality controls are defined. The performances of each detector, composed by two triple-GEM chambers equipped with dedicated CARDIAC-GEM front-end electronics, are studied with a cosmic ray telescope. The cosmic ray telescope has been set up including all the final off-detector components

    Aging measurements on triple-GEM detectors operated with CF4-based gas mixtures

    Get PDF
    We present the results of a global irradiation test of full size triple-GEM detectors operated with CF 4 -based gas mixtures. This study has been performed in the framework of an R&D activity on detectors for the innermost region of the first muon station of the LHCb experiment. The prototypes have been irradiated at the Calliope facility of the ENEA-Casaccia with a high intensity 1.25 MeV γ 60 Co source. After the irradiation test the detectors performances have been measured with X-rays and with a 3 GeV pion beam at CERN. A SEM analysis on several samples of the detectors has been performed to complete the understanding of the physical processes occurring in a GEM detector during a strong irradiation

    A complete simulation of a triple-GEM detector

    Get PDF
    Since some years the gas electron multipliers (GEM)based detectors have been proposed for many different applications, in particular, in high-energy physics and astrophysics experiments and medical imaging. Many experimental measurements and tests have been performed to investigate their characteristics and performances. To achieve a better understanding of the behavior of this kind of detector the computer simulation is a very important tool. In this paper, a complete and detailed simulation of a triple-GEM-based detector is described. A method has been developed to take into account all the processes from the ionization mechanism up to the signal formation and electronic response. The results obtained are compared with experimental data and a very good agreement is achieved

    A triple GEM gamma camera for medical application

    Get PDF
    Abstract A Gamma Camera for medical applications 10 × 10 cm 2 has been built using a triple GEM chamber prototype. The photon converters placed in front of the three GEM foils, has been realized with different technologies. The chamber, High Voltage supplied with a new active divider made in Frascati, is readout through 64 pads, 1 mm 2 wide, organized in a row of 8 cm long, with LHCb ASDQ chip. This Gamma Camera can be used both for X-ray movie and PET-SPECT imaging; this chamber prototype is placed in a scanner system, creating images of 8 × 8 cm 2 . Several measurements have been performed using phantom and radioactive sources of Tc 99 m ( 140 keV ) and Na 22 ( 511 keV ) . Results on spatial resolution and image reconstruction are presented
    • …
    corecore