14 research outputs found

    Effect of gender, facial dimensions, body mass index and type of functional occlusion on bite force

    Get PDF
    OBJECTIVE: Some factors such as gender, age, craniofacial morphology, body structure, occlusal contact patterns may affect the maximum bite force. Thus, the purposes of this study were to determine the mean maximum bite force in individuals with normal occlusion, and to examine the effect of gender, facial dimensions, body mass index (BMI), type of functional occlusion (canine guidance and group function occlusion) and balancing side interferences on it. MATERIAL AND METHODS: Thirty-four individuals aged 19-20 years-old were selected for this study. Maximum bite force was measured with strain-gauge transducers at first molar region. Facial dimensions were defined by standardized frontal photographs as follows: anterior total facial height (ATFH), bizygomathic facial width (BFW) and intergonial width (IGW). BMI was calculated using the equation weight/height². The type of functional occlusion and the balancing side interferences of the subjects were identified by clinical examination. RESULTS: Bite force was found to be significantly higher in men than women (

    The bite force and craniofacial morphology in patients with acromegaly: a pilot study

    Get PDF
    Objectives: Acromegaly is a metabolic disorder caused by increased growth hormone secretion. As a consequence of acromegaly some typical craniofacial morphology changes appear. This pilot study was conducted to compare the bite force and the characteristic size and shape of the craniofacial components of acromegalic patients with the healthy Turkish individuals. In additon, the correlations between bite force and craniofacial morphology of patients with acromegaly and control individuals were evaluated. Study Design: The maximum bite force of the participants was recorded with strain-gage transducer. Lateral xray scans were made under standard conditions, in centric occlusion. On cephalograms, the linear and angular measurements was performed. Results: Patients with acromegaly showed increased anterior and posterior total face height, ramus length, width of frontal sinuse, gonial angle and a negative difference between maxillary and mandibular protrusions. In addition, females with acromegaly showed larger lower anterior face height and sella turcica, decreased facial angle, increased mandibular plane angle. The cephalometric measurements, except one did not showed correlation with the bite force in acromegalic patients. In control group, significant correlations were observed between anterior total face height and anterior lower face height, mandibular plane angle and gonial angle. Conclusions: The greater changes were observed in the mandible. The maximum bite force of patients with acromegaly showed no difference from healthy individuals. The non-significant difference of bite force between healthy participants and acromegalic patients provide important information for dental treatment and prosthetic rehabilitation of acromegalic patients

    The effect of Esthetic fibers on impact resistance of a conventional heat-cured denture base resin

    No full text
    This study was conducted to observe the changes in impact resistance of a denture base resin reinforced with five types of fiber. E-glass, polyester, rayon, nylon 6, and nylon 6/6 fibers were cut into 2, 4, and 6 mm lengths and added into the resin at a concentration of 3% by weight. Five test specimens for each formulation, as well as control specimens without fiber, were prepared using a mold including a V-shaped notch with 55 x 10 x 10 mm dimensions. Impact tests were carried out using a Charpy-type tester. Additionally, surfaces of the impact sections were observed under a scanning electron microscope (SEM). Results indicated that impact energy tended to increase with fiber length, and that the highest value was recorded for rayon fiber-reinforced specimens of 6 mm length. E-glass fiber reinforcement produced relatively stable, high values for each length, whereby good interfacial strength between polymer matrix and glass fibers was confirmed by SEM analysis

    Evaluation of laser treatment on reline-base composites

    No full text
    The effects of different laser treatments on some mechanical properties of acrylic resin and soft liner were investigated. A total of 60 test specimens were fabricated according to test requirements. The specimens were roughened with Potassium-ticanyl-Phosphate (KTP), Er:YAG, and Nd:YAG lasers before application of soft liner. The flexural, peel, and tensile bond strengths were measured using a universal testing machine. Fourier transform infrared spectroscopy with attenuated total reflectance (FTIR-ATR) spectra of surfaces were also obtained to evaluate changes on the lased surfaces. No significant difference was apparent between the tensile bond strength values of the groups. Although peel strength values obtained for each of the laser types were lower than those of the control group, flexural strength values were higher than those of the control specimens. The spectra of specimens showed that lasing led to some chemical changes on the resin surfaces. Physical changes on the treated surfaces were visualized by scanning electron microscopy (SEM) analysis. Results of this study suggest that such treatments may be warranted because of the increase in flexural strength

    Flexural and bonding properties of a denture base polymer treated with nitric acid or ultraviolet radiation before relining with Molloplast-b

    No full text
    This study investigated adhesive forces and flexural strength of acrylic resin denture base relined with Molloplast-B soft lining material. To increase bonding between the two materials, the surface of the resin was modified with ultraviolet (UV) irradiation or nitric acid treatment. The peel strength greatly increased with nitric acid treatment because of the high polarity on the poly (methyl methacrylate) (PMMA) surface and the increase in the surface roughness, whereas low peel strength was seen with the UV treatment of the PMMA surface. Although both types of the surface pretreatment increased the flexural strength of PMMA-reline composites compared with the control and bulk PMMA groups, the increase in the UV-treated group was found to be higher than that of the nitric acid treated group

    Treatment Of Implant-Related Methicillin-Resistant Staphylococcus Aureus Osteomyelitis With Vancomycin-Loaded Vk100 Silicone Cement: An Experimental Study In Rats

    Get PDF
    Introduction: The purpose of this present study is to investigate the efficacy of vancomycin-loaded VK100 silicone cement drug delivery system in the treatment of implant-related methicillin-resistant Staphylococcus aureus (MRSA) osteomyelitis in rats. Materials and Methods: Thirty-six adult (18-20 weeks old) female Sprague-Dawley rats were included in the study. All rats underwent experimental osteomyelitis surgery via injecting 100 mu L bacterial suspension of MRSA into the medullary canal. After a 2-week duration for the formation of osteomyelitis model, rats were assigned Introduction: randomly into four groups: control (C), systemic vancomycin (V), local vancomycin-loaded VK100 silicone cement (vVK100), and systemic vancomycin and local vancomycin-loaded VK100 silicone cement (V+vVK100). The following treatment protocols were administered to each group for 4 weeks. For group C, 0.9% saline solution equivalent to the volume of vancomycin dose (approximately 1 ml/kg) was administered intraperitoneally twice daily (12-h intervals). For group V, 15 mg/kg of vancomycin was administered intraperitoneally twice daily (12-h intervals). For group vVK100, vVK100 polymer was included so that the intramedullary canal of the rats are affected. For group V+vVK100, vVK100 polymer was included so that the intramedullary canal of the rats are affected and 15 mg/kg of vancomycin was administered intraperitoneally twice daily (12-h intervals). After 4 weeks of treatment, clinical, radiologic, microbiologic, and histopathologic evaluations were performed for all groups. Results: Results of this study revealed that all scores of the evaluation criteria for the treatment groups (groups V, vVK100, and V+vVK100) decreased due to the treatment protocols when compared to group C. These results show the effectiveness of all treatment protocols for the implant-related chronic MRSA osteomyelitis. However, there were no statistical difference between these three protocols. Conclusions: vVK100 polymer, as a local antibiotic delivery system, seems to be an effective method for the treatment of implant-related chronic MRSA osteomyelitis.WoSScopu
    corecore