148 research outputs found

    Doppler and birth weight Z score: predictors for adverse neonatal outcome in severe fetal compromise

    Get PDF
    BACKGROUND: An adequate placental perfusion is crucial for the normal growth and well being of the fetus and newborn. The blood flow through the placenta can be compromised in a variety of clinical situations, always causing important damage to the gestation. Our objective is to identify significant predictors for adverse neonatal outcome in severe fetal compromise. METHODS: Consecutive premature fetuses at between 25 and 32 weeks with severe placental insufficiency were examined prospectively. Inclusion criteria were: (i) singletons (ii) normal anatomy; (iii) abnormal umbilical artery Doppler pulsatility index (PI); (iv) abnormal cerebroplacental ratio; (v) middle cerebral artery (MCA) PI < - 2SD ("brain sparing"); (vi) last Doppler examination performed within 24 hours prior to delivery. All 46 patients that met criteria and started the study were followed to the end. We considered as independent potential predicting variables: absent or reversed end diastolic flow in umbilical artery, abnormal ductus venosus S/A ratio, absent or reversed flow during atrial contraction in the ductus venosus and birth weight Z score. Outcome parameters were: neonatal mortality and severe neonatal morbidity. RESULTS: Backward stepwise logistic regression analysis was used to determine the optimal model for the prediction of neonatal mortality and severe neonatal morbidity. In this analysis birth weight Z score index showed the strongest association OR = 1,87 [1,17-2,99] with all neonatal outcome, all other independent variables were excluded for the optimal model. There was no mortality for the group with normal birth weight Z score. CONCLUSION: Our study suggests that birth weight Z score is the strongest predictor of adverse neonatal outcome in severe placental insufficiencies. Such use of Z scores, allowing to get rid of gestational age or sex covariates could be extended to estimated fetal weight and might help in making important decisions in the management of compromised pregnancies

    Adenovirus DNA in Guthrie cards from children who develop acute lymphoblastic leukaemia (ALL)

    Get PDF
    Aims: The aim of this thesis was to increase understanding of how molecular processes influence the development and risk assessment of childhood leukemia. Studies I and II investigates whether a specific virus infection in utero could be involved in a “first hit” in leukemogenesis. Studies III and IV examine whether alterations in protein expression from cell cycle regulating genes may predict a relapse in children with myeloid malignancies undergoing hematopoietic stem cell transplantation (HSCT). Background: Genetic alterations, analyzed at time of diagnosis in children who develop leukemia, have been traced back to neonatal dried blood spots (DBS). This suggests that the majority of chromosome translocations occur in utero during fetal hematopoiesis, generating a “first hit”. A “second hit” is then required to generate a leukemic clone. Today, experiments in vitro, animal models, and clinical observations have revealed that several viruses are oncogenic and capable of initiating a genetic alteration. Smith M postulated the theory that an in utero infection might be the “first hit”, causing genetic aberrations that could later lead to the development of the leukemic clone, which is supported by the early age of onset and space-time clustering data, based on time, place of birth, and diagnosis. Leukemia develops as a result of hematopoietic or lymphoid tissue with uncontrolled cell division. Normally cell division is controlled by the cell cycle, the network of which is complex with numerous regulating proteins both up and down stream, but also containing several feedback loops. The important regulators of this process are tumor suppressor genes, essential for normal cell proliferation and differentiation as well as for controlling DNA integrity. Errors in these genes or their protein expression affect the ability of the cell to check for DNA damage, thus tumors may occur. Proteins from these genes could serve as prognostic markers and predict relapse. Methods: In studies I and II we investigated neonatal DBS by PCR for the presence of adenovirus DNA (243 samples) and the three newly discovered polyomaviruses (50 samples) from children who later developed leukemia but also from controls (486 and 100 samples respectively). In studies III and IV we explored the expression of one (p53) respectively four (p53, p21, p16 and PTEN) cell cycle regulating proteins in bone marrow at diagnosis as well as pre and post HSCT in myeloid malignancies in children. We retrospectively collected clinical data and bone marrow samples from 33 children diagnosed with chronic myeloid malignancies (MDS, JMML and CML), 34 children diagnosed with AML as well as 55 controls. The samples were prepared by tissue micro array (TMA) as well as immunohistochemistry and examined for protein expression in a light microscope. Results: In study I we detected adenovirus DNA in only two patients who later developed leukemia, but in none of the controls. In study II all the samples were negative for KIPyV, WUPyV and MCPyV DNA in both patients and controls. In study III we found an overexpression of p53 protein at diagnosis that significantly predicted relapse after HSCT in children with rare chronic myeloid malignancies. In study IV a significantly higher p53 expression was found in the relapse compared to the non-relapse group at six months post HSCT in children with AML, suggesting that p53 may be used as prognostic markers for predicting a relapse. In addition, the calculated cut off level for p53 at diagnosis (study III) and at six months (study IV) post HSCT was approximately 20%, which indicates that a p53 expression over 20% may predict relapse in children with myeloid malignancies. Conclusion: Although we did not find an association between adenoviruses or the three newly discovered polyomaviruses and the development of childhood leukemia, a virus could still be involved in this process; the virus may have escaped detection, other new viruses could be involved or a virus could precipitate the “second hit”. We suggest that evaluation of p53 protein expression may be used as a supplement to regular prognostic markers both pre and post HSCT. To further evaluate this, a prospective multicenter study has been started

    Developmental Trajectories of Body Mass Index Among Japanese Children and Impact of Maternal Factors during Pregnancy

    Get PDF
    Background The aims of this study were to 1) determine the distinct patterns of body mass index (BMI) trajectories in Japanese children, and 2) elucidate the maternal factors during pregnancy, which contribute to the determination of those patterns. Methodology/Principal Findings All of the children (1,644 individuals) born in Koshu City, Japan, between 1991 and 1998 were followed in a longitudinal study exploring the subjects’ BMI. The BMI was calculated 11 times for each child between birth and 12 years of age. Exploratory latent class growth analyses were conducted to identify trajectory patterns of the BMI z-scores. The distribution of BMI trajectories were best characterized by a five-group model for boys and a six-group model for girls. The groups were named “stable thin,” “stable average,” “stable high average,” “progressive overweight,” and “progressive obesity” in both sexes; girls were allocated to an additional group called “progressive average.” Multinomial logistic regression found that maternal weight, smoking, and skipping breakfast during pregnancy were associated with children included in the progressive obesity pattern rather than the stable average pattern. These associations were stronger for boys than for girls. Conclusions/Significance Multiple developmental patterns in Japanese boys and girls were identified, some of which have not been identified in Western countries. Maternal BMI and some unfavorable behaviors during early pregnancy may impact a child’s pattern of body mass development. Further studies to explain the gender and regional differences that were identified are warranted, as these may be important for early life prevention of weight-associated health problems

    Comparison of diurnal variations, gestational age and gender related differences in fetal heart rate (FHR) parameters between appropriate-for-gestational-age (AGA) and small-for-gestational-age (SGA) fetuses in the home environment

    Get PDF
    Objective To assess the influence of gender, time of the day and gestational age on fetal heart rate (FHR) parameters between appropriate-for-gestational-age (AGA) and small-for-gestational age (SGA) fetuses using a portable fetal ECG monitor employed in the home setting. Methods We analysed and compared the antenatal FHR data collected in the home setting on 61 healthy pregnant women with singleton pregnancies from 24 weeks gestation. Of the 61 women, 31 had SGA fetuses (estimated fetal weight below the tenth gestational centile) and 30 were pregnant with AGA fetuses. FHR recordings were collected for up to 20 h. Two 90 min intervals were deliberately chosen retrospectively with respect to signal recording quality, one during day-time and one at night-time for comparison. Results Overall, success rate of the fetal abdominal ECG in the AGA fetuses was 75.7% compared to 48.6% in the SGA group. Based on randomly selected episodes of heart rate traces where recording quality exceeded 80% we were able to show a marginal difference between day and night-time recordings in AGA vs. SGA fetuses beyond 32 weeks of gestation. A selection bias in terms of covering different representation periods of fetal behavioural states cannot be excluded. In contrast to previous studies, we neither controlled maternal diet and activity nor measured maternal blood hormone and heart rate as all mothers were monitored in the home environment. Conclusion Based on clinically unremarkable, but statistically significant differences in the FHR parameters between the AGA and SGA group we suggest that further studies with large sample size are required to assess the clinical value of antenatal fetal ECG monitoring

    Adenovirus DNA is detected at increased frequency in Guthrie cards from children who develop acute lymphoblastic leukaemia

    Get PDF
    Epidemiological evidence suggests that childhood acute lymphoblastic leukaemia (ALL) may be initiated by an in infection in utero. Adenovirus DNA was detected in 13 of 49 neonatal blood spots from ALL patients but only in 3 of 47 controls (P=0.012) suggesting a correlation between prenatal adenovirus infection and the development of AL

    Symphysis-fundal height curve in the diagnosis of fetal growth deviations

    Get PDF
    OBJECTIVE: To validate a new symphysis-fundal curve for screening fetal growth deviations and to compare its performance with the standard curve adopted by the Brazilian Ministry of Health. METHODS: Observational study including a total of 753 low-risk pregnant women with gestational age above 27 weeks between March to October 2006 in the city of João Pessoa, Northeastern Brazil. Symphisys-fundal was measured using a standard technique recommended by the Brazilian Ministry of Health. Estimated fetal weight assessed through ultrasound using the Brazilian fetal weight chart for gestational age was the gold standard. A subsample of 122 women with neonatal weight measurements was taken up to seven days after estimated fetal weight measurements and symphisys-fundal classification was compared with Lubchenco growth reference curve as gold standard. Sensitivity, specificity, positive and negative predictive values were calculated. The McNemar χ2 test was used for comparing sensitivity of both symphisys-fundal curves studied. RESULTS: The sensitivity of the new curve for detecting small for gestational age fetuses was 51.6% while that of the Brazilian Ministry of Health reference curve was significantly lower (12.5%). In the subsample using neonatal weight as gold standard, the sensitivity of the new reference curve was 85.7% while that of the Brazilian Ministry of Health was 42.9% for detecting small for gestational age. CONCLUSIONS: The diagnostic performance of the new curve for detecting small for gestational age fetuses was significantly higher than that of the Brazilian Ministry of Health reference curve

    Early influences on cardiovascular and renal development

    Full text link
    corecore