51 research outputs found
Access to
The shortage of appropriate donor organs and the expanding pool of patients waiting for heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. Improved results and the increased applicability and durability with left ventricular assist devices (LVADs) have enhanced this treatment option available for end-stage heart failure patients. Moreover, outcome with newer pumps have evolved to destination therapy for such patients. Currently, results using nonpulsatile continuous flow pumps document the evolution in outcomes following destination therapy achieved subsequent to the landmark Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure Trial (REMATCH), as well as the outcome of pulsatile designed second-generation LVADs. This review describes the currently available types of LVADs, their clinical use and outcomes, and focuses on the patient selection process
Distribution of Cardiac Stem Cells in the Human Heart
Introduction.
The existence of human cardiac stem cells (hCSC) and their regenerative capacity are not fully defined. The aim of this study was to identify and analyse the distribution of hCSCs by flow cytometry (FCM). Methods. Tissue samples from the left ventricle (LV) and the appendages of the right atrium (RA) and left atrium (LA) were taken during cardiac surgery. Mononuclear cells (MNCs) were isolated, labelled for the stem-cell-marker c-kit and hematopoietic-lineage markers and analysed by FCM. Results. HCSCs could be isolated from the RA, LA, and LV without significant quantitative difference between both atria (A) (RA 4.80 ± 1.76% versus LA 4.99 ± 1.69% of isolated MNCs, P = 0.922). The number of hCSCs was significantly higher in both atria compared to the left ventricle (A 4.90 ± 1.29% versus LV 0.62 ± 0.14% of isolated MNCs, P = 0.035). Conclusion. The atria contain a higher concentration of hCSC than the left ventricle. HCSCs located in the atria could serve as an endogenous source for heart regeneration
Everolimus-Induced Immune Effects after Heart Transplantation: A Possible Tool for Clinicians to Monitor Patients at Risk for Transplant Rejection
Background: Patients treated with an inhibitor of the mechanistic target of rapamycin (mTORI) in a calcineurin inhibitor (CNI)-free immunosuppressive regimen after heart transplantation (HTx) show a higher risk for transplant rejection. We developed an immunological monitoring tool that may improve the identification of mTORI-treated patients at risk for rejection. Methods: Circulating dendritic cells (DCs) and regulatory T cells (Tregs) were analysed in 19 mTORI- and 20 CNI-treated HTx patients by flow cytometry. Principal component and cluster analysis were used to identify patients at risk for transplant rejection. Results: The percentages of total Tregs (p = 0.02) and CD39+ Tregs (p = 0.05) were higher in mTORI-treated patients than in CNI-treated patients. The principal component analysis revealed that BDCA1+, BDCA2+ and BDCA4+ DCs as well as total Tregs could distinguish between non-rejecting and rejecting mTORI-treated patients. Most mTORI-treated rejectors showed higher levels of BDCA2+ and BDCA4+ plasmacytoid DCs and lower levels of BDCA1+ myeloid DCs and Tregs than mTORI non-rejectors. Conclusion: An mTORI-based immunosuppressive regimen induced a sufficient, tolerance-promoting reaction in Tregs, but an insufficient, adverse effect in DCs. On the basis of patient-specific immunological profiles, we established a flow cytometry-based monitoring tool that may be helpful in identifying patients at risk for rejection
Immune Monitoring Assay for Extracorporeal Photopheresis Treatment Optimization After Heart Transplantation
Background: Extracorporeal photopheresis (ECP) induces immunological changes that
lead to a reduced risk of transplant rejection. The aim of the present study was to
determine optimum conditions for ECP treatment by analyzing a variety of toleranceinducing
immune cells to optimize the treatment.
Methods: Ten ECP treatments were applied to each of 17 heart-transplant patients from
month 3 to month 9 post-HTx. Blood samples were taken at baseline, three times during
treatment, and four months after the last ECP treatment. The abundance of subsets of
tolerance-inducing regulatory T cells (Tregs) and dendritic cells (DCs) in the samples was
determined by flow cytometry. A multivariate statistical model describing the
immunological status of rejection-free heart transplanted patients was used to visualize
the patient-specific immunological improvement induced by ECP.
Results: All BDCA+ DC subsets (BDCA1+ DCs: p < 0.01, BDCA2+ DCs: p < 0.01,
BDCA3+ DCs: p < 0.01, BDCA4+ DCs: p < 0.01) as well as total Tregs (p < 0.01) and
CD39+ Tregs (p < 0.01) increased during ECP treatment, while CD62L+ Tregs decreased
(p < 0.01). The cell surface expression level of BDCA1 (p < 0.01) and BDCA4 (p < 0.01) on
DCs as well as of CD120b (p < 0.01) on Tregs increased during the study period, while
CD62L expression on Tregs decreased significantly (p = 0.04). The cell surface expression
level of BDCA2 (p = 0.47) and BDCA3 (p = 0.22) on DCs as well as of CD39 (p = 0.14) and
CD147 (p = 0.08) on Tregs remained constant during the study period. A cluster analysis
showed that ECP treatment led to a sustained immunological improvement.
Conclusions: We developed an immune monitoring assay for ECP treatment after heart
transplantation by analyzing changes in tolerance-inducing immune cells. This assay
allowed differentiation of patients who did and did not show immunological improvement.
Based on these results, we propose classification criteria that may allow optimization of
the duration of ECP treatment
Prognostic impact of implantable cardioverter defibrillators and associated adverse events in patients with continuous flow left ventricular assist devices
ObjectivesImplantation of implantable cardioverter defibrillators (ICD) reduces the risk of all-cause mortality in symptomatic heart failure (HF) patients with severe left ventricular (LV) dysfunction. Nevertheless, the prognostic impact of ICD therapy in continuous flow left ventricular assist device (LVAD) recipients remains controversial.Methods162 consecutive HF patients, who underwent LVAD implantation at our institution between 2010 and 2019, were categorized according to the presence (n = 94, ICD-group) or absence (n = 68, Control-group) of ICDs. Apart from clinical baseline and follow-up parameters, adverse events (AEs) related to ICD therapy and overall survival rates were retrospectively analyzed.ResultsOut of 162 consecutive LVAD recipients 79 patients (48.8%) were preoperatively categorized as Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile ≤2. The prevalence of severe HF symptoms and preoperative use of short-term circulatory support devices (54.4% vs. 13.8%, p < 0.001) was higher within the Control-group, although baseline severity of LV and RV dysfunction was similar. Apart from an increased prevalence of perioperative right heart failure (RHF) within the Control-group (45.6% vs. 17.0%; p < 0.001), procedural characteristics and perioperative outcome were similar. Overall-survival during a median follow-up of 14 (3.0–36.5) months was similar within both groups (p = 0.46). During the first 2 years after LVAD implantation 53 ICD-related AEs occurred within the ICD-group. Thereof, lead-dysfunction occurred in 19 patients and unplanned ICD-reintervention in 11 patients. Furthermore, in 18 patients appropriate shocks without loss of consciousness occurred, whereas inappropriate shocks occurred in 5 patients.ConclusionICD therapy in LVAD recipients was not associated with a survival benefit or reduced morbidity after LVAD implantation. Conservative ICD-programming seems to be justified to avoid ICD-related complications and „awake shocks” after LVAD implantation
A proposal for early dosing regimens in heart transplant patients receiving thymoglobulin and calcineurin inhibition
There is currently no consensus regarding the dose or duration of rabbit antithymocyte globulin (rATG) induction in different types of heart transplant patients, or the timing and intensity of initial calcineurin inhibitor (CNI) therapy in rATG-treated individuals. Based on limited data and personal experience, the authors propose an approach to rATG dosing and initial CNI administration. Usually rATG is initiated immediately after exclusion of primary graft failure, although intraoperative initiation may be appropriate in specific cases. A total rATG dose of 4.5 to 7.5 mg/kg is advisable, tailored within that range according to immunologic risk and adjusted according to immune monitoring. Lower doses (eg, 3.0 mg/kg) of rATG can be used in patients at low immunological risk, or 1.5 to 2.5 mg/kg for patients with infection on mechanical circulatory support. The timing of CNI introduction is dictated by renal recovery, varying between day 3 and day 0 after heart transplantation, and the initial target exposure is influenced by immunological risk and presence of infection. Rabbit antithymocyte globulin and CNI dosing should not overlap except in high-risk cases. There is a clear need for more studies to define the optimal dosing regimens for rATG and early CNI exposure according to risk profile in heart transplantation
COVID-19 among heart transplant recipients in Germany: a multicenter survey
Abstract
Aims
Heart transplantation may represent a particular risk factor for severe coronavirus infectious disease 2019 (COVID-19) due to chronic immunosuppression and frequent comorbidities. We conducted a nation-wide survey of all heart transplant centers in Germany presenting the clinical characteristics of heart transplant recipients with COVID-19 during the first months of the pandemic in Germany.
Methods and results
A multicenter survey of all heart transplant centers in Germany evaluating the current status of COVID-19 among adult heart transplant recipients was performed. A total of 21 heart transplant patients with COVID-19 was reported to the transplant centers during the first months of the pandemic in Germany. Mean patient age was 58.6 ± 12.3 years and 81.0% were male. Comorbidities included arterial hypertension (71.4%), dyslipidemia (71.4%), diabetes mellitus (33.3%), chronic kidney failure requiring dialysis (28.6%) and chronic-obstructive lung disease/asthma (19.0%). Most patients received an immunosuppressive drug regimen consisting of a calcineurin inhibitor (71.4%), mycophenolate mofetil (85.7%) and steroids (71.4%). Eight of 21 patients (38.1%) displayed a severe course needing invasive mechanical ventilation. Those patients showed a high mortality (87.5%) which was associated with right ventricular dysfunction (62.5% vs. 7.7%; p = 0.014), arrhythmias (50.0% vs. none; p = 0.012), and thromboembolic events (50.0% vs. none; p = 0.012). Elevated high-sensitivity cardiac troponin T- and N-terminal prohormone of brain natriuretic peptide were significantly associated with the severe form of COVID-19 (p = 0.017 and p < 0.001, respectively).
Conclusion
Severe course of COVID-19 was frequent in heart transplanted patients. High mortality was associated with right ventricular dysfunction, arrhythmias, thromboembolic events, and markedly elevated cardiac biomarkers
The Intersection of Interfacial Forces and Electrochemical Reactions
We review recent developments in experimental techniques that simultaneously combine measurements of the interaction forces or energies between two extended surfaces immersed in electrolyte solutions—primarily aqueous—with simultaneous monitoring of their (electro)chemical reactions and controlling the electrochemical surface potential of at least one of the surfaces. Combination of these complementary techniques allows for simultaneous real time monitoring of angstrom level changes in surface thickness and roughness, surface–surface interaction energies, and charge and mass transferred via electrochemical reactions, dissolution, and adsorption, and/or charging of electric double layers. These techniques employ the surface forces apparatus (SFA) combined with various “electrochemical attachments” for in situ measurements of various physical and (electro)chemical properties (e.g., cyclic voltammetry), optical imaging, and electric potentials and currents generated naturally during an interaction, as well as when electric fields (potential differences) are applied between the surfaces and/or solution—in some cases allowing for the chemical reaction equation to be unambiguously determined. We discuss how the physical interactions between two different surfaces when brought close to each other (<10 nm) can affect their chemistry, and suggest further extensions of these techniques to biological systems and simultaneous in situ spectroscopic measurements for chemical analysis
Fluoroscopy-Guided Resolution of Ingested Thrombus Leading to Functional Disturbance of a Continuous-Flow Left Ventricular Assist Device
The third generation of left ventricular assist devices (LVADs) has been shown to improve outcome and quality of life in patients suffering from acute and chronic heart failure. However, VAD-associated complications are still a challenge in the clinical practice. Here we report the resolution of a mobile thrombus formation in the proximity of the inflow cannula of a third generation of LVADs (HVAD Pump, HeartWare, Inc.) in a patient with chronic heart failure 4 months after implantation
- …