123 research outputs found

    Accuracy of transcranial magnetic stimulation and a Bayesian latent class model for diagnosis of spinal cord dysfunction in horses

    Get PDF
    Background: Spinal cord dysfunction/compression and ataxia are common in horses. Presumptive diagnosis is most commonly based on neurological examination and cervical radiography, but the interest into the diagnostic value of transcranial magnetic stimulation (TMS) with recording of magnetic motor evoked potentials has increased. The problem for the evaluation of diagnostic tests for spinal cord dysfunction is the absence of a gold standard in the living animal. Objectives: To compare diagnostic accuracy of TMS, cervical radiography, and neurological examination. Animals: One hundred seventy-four horses admitted at the clinic for neurological examination. Methods: Retrospective comparison of neurological examination, cervical radiography, and different TMS criteria, using Bayesian latent class modeling to account for the absence of a gold standard. Results: The Bayesian estimate of the prevalence (95% CI) of spinal cord dysfunction was 58.1 (48.3%-68.3%). Sensitivity and specificity of neurological examination were 97.6 (91.4%-99.9%) and 74.7 (61.0%-96.3%), for radiography they were 43.0 (32.3%-54.6%) and 77.3 (67.1%-86.1%), respectively. Transcranial magnetic stimulation reached a sensitivity and specificity of 87.5 (68.2%-99.2%) and 97.4 (90.4%-99.9%). For TMS, the highest accuracy was obtained using the minimum latency time for the pelvic limbs (Youden's index = 0.85). In all evaluated models, cervical radiography performed poorest. Clinical Relevance: Transcranial magnetic stimulation-magnetic motor evoked potential (TMS-MMEP) was the best test to diagnose spinal cord disease, the neurological examination was the second best, but the accuracy of cervical radiography was low. Selecting animals based on neurological examination (highest sensitivity) and confirming disease by TMS-MMEP (highest specificity) would currently be the optimal diagnostic strategy

    Determination of the magnetic penetration depth in a superconducting Pb film

    Full text link
    peer reviewedBy means of scanning Hall probe microscopy technique we accurately map the magnetic field pattern produced by Meissner screening currents in a thin superconducting Pb stripe. The obtained field profile allows us to quantitatively estimate the Pearl length Λ without the need of pre-calibrating the Hall sensor. This fact contrasts with the information acquired through the spatial field dependence of an individual flux quantum where the scanning height and the magnetic penetration depth combine in a single inseparable parameter. The derived London penetration depth λL coincides with the values previously reported for bulk Pb once the kinetic suppression of the order parameter is properly taken into account

    Determination of the magnetic penetration depth in a superconducting Pb film

    Get PDF
    Under the terms of the Creative Commons Attribution (CC BY) license to their work.By means of scanning Hall probe microscopy technique, we accurately map the magnetic field pattern produced by Meissner screening currents in a thin superconducting Pb stripe. The obtained field profile allows us to quantitatively estimate the Pearl length ¿ without the need of pre-calibrating the Hall sensor. This fact contrasts with the information acquired through the spatial field dependence of an individual flux quantum where the scanning height and the magnetic penetration depth combine in a single inseparable parameter. The derived London penetration depth λL coincides with the values previously reported for bulk Pb once the kinetic suppression of the order parameter is properly taken into account.This work was partially supported by the Fonds de la Recherche Scientique-FNRS, the Methusalem Funding of the Flemish Government, the Fund for Scientic Research-Flanders (FWO-Vlaanderen), and the ARC Grant 13/18-08 for Concerted Research Actions, financed by the Wallonia-Brussels Federation. J.B. acknowledges support from FRS-FNRS (Research Fellowship). J.V.d.V. acknowledges support from FWO-Vl. The work of A.V.S. was partially supported by “Crédit de demurrage,” U.Lg.Peer Reviewe

    Determination of magnetic motor evoked potential latency time cutoff values for detection of spinal cord dysfunction in horses

    Get PDF
    Background: Transcranial magnetic stimulation (TMS) and recording of magnetic motor evoked potentials (MMEP) can detect neurological dysfunction in horses but cutoff values based on confirmed spinal cord dysfunction are lacking. Objectives: To determine latency time cutoff for neurological dysfunction. Animals Five control horses and 17 horses with proprioceptive ataxia. Methods: Case-control study with receiver operating characteristic curve analysis, based on diagnostic imaging, TMS, and histopathological findings. Horses were included if all 3 examinations were performed. Results: Diagnostic imaging and histopathology did not show abnormalities in the control group but confirmed spinal cord compression in 14 of 17 ataxic horses. In the remaining 3 horses, histopathological lesions were mild to severe, but diagnostic imaging did not confirm spinal cord compression. In control horses, latency time values of thoracic and pelvic limbs were significantly lower than in ataxic horses (20 +/- 1 vs 34 +/- 16 milliseconds, P = .05; and 39 +/- 1 vs 78 +/- 26 milliseconds, P = .004). Optimal cutoff values to detect spinal cord dysfunction were 22 milliseconds (sensitivity [95% CI interval], 88% [73%-100%]; specificity, 100% [100%-100%]) in thoracic and 40 milliseconds (sensitivity, 94% [83%-100%]; specificity, 100% [100%-100%]) in pelvic limbs. To detect spinal cord dysfunction caused by compression, the optimal cutoff for thoracic limbs remained 22 milliseconds, while it increased to 43 milliseconds in pelvic limbs (sensitivity, 100% [100%-100%]; specificity, 100% [100%-100%] for thoracic and pelvic limbs). Conclusions and Clinical Importance: Magnetic motor evoked potential analysis using these cutoff values is a promising diagnostic tool for spinal cord dysfunction diagnosis in horses

    Metastable states and hidden phase slips in nanobridge SQUIDs

    Full text link
    We fabricated an asymmetric nanoscale SQUID consisting of one nanobridge weak link and one Dayem bridge weak link. The current phase relation of these particular weak links is characterized by multivaluedness and linearity. While the latter is responsible for a particular magnetic field dependence of the critical current (so-called vorticity diamonds), the former enables the possibility of different vorticity states (phase winding numbers) existing at one magnetic field value. In experiments the observed critical current value is stochastic in nature, does not necessarily coincide with the current associated with the lowest energy state and critically depends on the measurement conditions. In this work, we unravel the origin of the observed metastability as a result of the phase dynamics happening during the freezing process and while sweeping the current. Moreover, we employ special measurement protocols to prepare the desired vorticity state and identify the (hidden) phase slip dynamics ruling the detected state of these nanodevices. In order to gain insights into the dynamics of the condensate and, more specifically the hidden phase slips, we performed time-dependent Ginzburg-Landau simulations.Comment: 10 pages, 4 figures, 1 supplementary vide

    Bone marrow-derived monocytes give rise to self-renewing and fully differentiated Kupffer cells

    Get PDF
    Self-renewing tissue-resident macrophages are thought to be exclusively derived from embryonic progenitors. However, whether circulating monocytes can also give rise to such macrophages has not been formally investigated. Here we use a new model of diphtheria toxin-mediated depletion of liver-resident Kupffer cells to generate niche availability and show that circulating monocytes engraft in the liver, gradually adopt the transcriptional profile of their depleted counterparts and become long-lived self-renewing cells. Underlining the physiological relevance of our findings, circulating monocytes also contribute to the expanding pool of macrophages in the liver shortly after birth, when macrophage niches become available during normal organ growth. Thus, like embryonic precursors, monocytes can and do give rise to self-renewing tissue-resident macrophages if the niche is available to them

    Intracellular delivery of mRNA in adherent and suspension cells by vapor nanobubble photoporation

    Get PDF
    Efficient and safe cell engineering by transfection of nucleic acids remains one of the long-standing hurdles for fundamental biomedical research and many new therapeutic applications, such as CAR T cell-based therapies. mRNA has recently gained increasing attention as a more safe and versatile alternative tool over viral- or DNA transposon-based approaches for the generation of adoptive T cells. However, limitations associated with existing nonviral mRNA delivery approaches hamper progress on genetic engineering of these hard-to-transfect immune cells. In this study, we demonstrate that gold nanoparticle-mediated vapor nanobubble (VNB) photoporation is a promising upcoming physical transfection method capable of delivering mRNA in both adherent and suspension cells. Initial transfection experiments on HeLa cells showed the importance of transfection buffer and cargo concentration, while the technology was furthermore shown to be effective for mRNA delivery in Jurkat T cells with transfection efficiencies up to 45%. Importantly, compared to electroporation, which is the reference technology for nonviral transfection of T cells, a fivefold increase in the number of transfected viable Jurkat T cells was observed. Altogether, our results point toward the use of VNB photoporation as a more gentle and efficient technology for intracellular mRNA delivery in adherent and suspension cells, with promising potential for the future engineering of cells in therapeutic and fundamental research applications

    Thermoelectric spin voltage in graphene

    Get PDF
    In recent years, new spin-dependent thermal effects have been discovered in ferromagnets, stimulating a growing interest in spin caloritronics, a field that exploits the interaction between spin and heat currents. Amongst the most intriguing phenomena is the spin Seebeck effect, in which a thermal gradient gives rise to spin currents that are detected through the inverse spin Hall effect. Non-magnetic materials such as graphene are also relevant for spin caloritronics, thanks to efficient spin transport, energy-dependent carrier mobility and unique density of states. Here, we propose and demonstrate that a carrier thermal gradient in a graphene lateral spin valve can lead to a large increase of the spin voltage near to the graphene charge neutrality point. Such an increase results from a thermoelectric spin voltage, which is analogous to the voltage in a thermocouple and that can be enhanced by the presence of hot carriers generated by an applied current. These results could prove crucial to drive graphene spintronic devices and, in particular, to sustain pure spin signals with thermal gradients and to tune the remote spin accumulation by varying the spin-injection bias

    Determination of the spin-lifetime anisotropy in graphene using oblique spin precession

    Get PDF
    We determine the spin-lifetime anisotropy of spin-polarized carriers in graphene. In contrast to prior approaches, our method does not require large out-of-plane magnetic fields and thus it is reliable for both low-and high-carrier densities. We first determine the in-plane spin lifetime by conventional spin precession measurements with magnetic fields perpendicular to the graphene plane. Then, to evaluate the out-of-plane spin lifetime, we implement spin precession measurements under oblique magnetic fields that generate an out-of-plane spin population. We find that the spin-lifetime anisotropy of graphene on silicon oxide is independent of carrier density and temperature down to 150 K, and much weaker than previously reported. Indeed, within the experimental uncertainty, the spin relaxation is isotropic. Altogether with the gate dependence of the spin lifetime, this indicates that the spin relaxation is driven by magnetic impurities or random spin-orbit or gauge fields
    corecore