63 research outputs found

    Automated algorithm for CBCT-based dose calculations of prostate radiotherapy with bilateral hip prostheses

    Get PDF
    ABSTRACTOBJECTIVE:Cone beam CT (CBCT) images contain more scatter than a conventional CT image and therefore provide inaccurate Hounsfield units (HUs). Consequently, CBCT images cannot be used directly for radiotherapy dose calculation. The aim of this study is to enable dose calculations to be performed with the use of CBCT images taken during radiotherapy and evaluate the necessity of replanning.METHODS:A patient with prostate cancer with bilateral metallic prosthetic hip replacements was imaged using both CT and CBCT. The multilevel threshold (MLT) algorithm was used to categorize pixel values in the CBCT images into segments of homogeneous HU. The variation in HU with position in the CBCT images was taken into consideration. This segmentation method relies on the operator dividing the CBCT data into a set of volumes where the variation in the relationship between pixel values and HUs is small. An automated MLT algorithm was developed to reduce the operator time associated with the process. An intensity-modulated radiation therapy plan was generated from CT images of the patient. The plan was then copied to the segmented CBCT (sCBCT) data sets with identical settings, and the doses were recalculated and compared.RESULTS:Gamma evaluation showed that the percentage of points in the rectum with γ < 1 (3%/3 mm) were 98.7% and 97.7% in the sCBCT using MLT and the automated MLT algorithms, respectively. Compared with the planning CT (pCT) plan, the MLT algorithm showed −0.46% dose difference with 8 h operator time while the automated MLT algorithm showed −1.3%, which are both considered to be clinically acceptable, when using collapsed cone algorithm.CONCLUSION:The segmentation of CBCT images using the method in this study can be used for dose calculation. For a patient with prostate cancer with bilateral hip prostheses and the associated issues with CT imaging, the MLT algorithms achieved a sufficient dose calculation accuracy that is clinically acceptable. The automated MLT algorithm reduced the operator time associated with implementing the MLT algorithm to achieve clinically acceptable accuracy. This saved time makes the automated MLT algorithm superior and easier to implement in the clinical setting.ADVANCES IN KNOWLEDGE:The MLT algorithm has been extended to the complex example of a patient with bilateral hip prostheses, which with the introduction of automation is feasible for use in adaptive radiotherapy, as an alternative to obtaining a new pCT and reoutlining the structures

    Dosimetric feasibility of magnetic resonance (MR)-based dose calculation of prostate radiotherapy using multilevel threshold algorithm

    Get PDF
    Objective: The development of magnetic resonance (MR) imaging systems has been extended for the entire radiotherapy process. However, MR images provide voxel values that are not directly related to electron densities (ED), thus MR images cannot be used directly for dose calculation. The aim of this study is to investigate the feasibility of dose calculations to be performed on MR images and evaluate the necessity of re-planning.Methods: A prostate cancer patient was imaged using both MR and CT. The multilevel threshold algorithm (MLT) was used categorise to voxel values in the MR images in into three segments (air, water and bone) with homogeneous Hounsfield units (HU). An intensity modulated radiation therapy (IMRT) plan was generated from CT images of the patient. The plan was then copied to the segmented MR data sets and the doses were recalculated using pencil beam, and collapsed cone (CC) algorithms and Monte Carlo (MC) modelling.Results: Gamma evaluation showed that the percentage of points in regions of interest with γ < 1 (3%/3 mm) were more than 94% in the segmented MR. Compared with the planning CT (pCT) plan, the segmented MR plan resulted in a dose difference of –0.3%, 0.8% and –1.3% when using PB, CC and MC algorithms, respectively.Conclusion: The segmentation and conversion of MR images into HUs data using the MLT algorithm, used in this feasibility study, can be used for dose calculation. This method can be used as a dosimetric assessment tool and can be easily implemented into the clinic

    Characterisation of barley resistance to rhynchosporium on chromosome 6HS

    Get PDF
    Key Message: Major resistance gene to rhynchosporium, Rrs18, maps close to the telomere on the short arm of chromosome 6H in barley. Rhynchosporium or barley scald caused by a fungal pathogen Rhynchosporium commune is one of the most destructive and economically important diseases of barley in the world. Testing of Steptoe × Morex and CIho 3515 × Alexis doubled haploid populations has revealed a large effect QTL for resistance to R. commune close to the telomere on the short arm of chromosome 6H, present in both populations. Mapping markers flanking the QTL from both populations onto the 2017 Morex genome assembly revealed a rhynchosporium resistance locus independent of Rrs13 that we named Rrs18. The causal gene was fine mapped to an interval of 660 Kb using Steptoe × Morex backcross 1 S₂ and S₃ lines with molecular markers developed from Steptoe exome capture variant calling. Sequencing RNA from CIho 3515 and Alexis revealed that only 4 genes within the Rrs18 interval were transcribed in leaf tissue with a serine/threonine protein kinase being the most likely candidate for Rrs18.Max Coulter, Bianca Büttner, Kerstin Hofmann, Micha Bayer, Luke Ramsay, Günther Schweizer, Robbie Waugh, Mark E. Looseley, Anna Avrov

    Synthesising Corporate Responsibility on Organisational and Societal Levels of Analysis: An Integrative Perspective

    Get PDF
    This article develops an integrative perspective on corporate responsibility by synthesising competing perspectives on the responsibility of the corporation at the organisational and societal levels of analysis. We review three major corporate responsibility perspectives, which we refer to as economic, critical, and politico-ethical. We analyse the major potential uses and pitfalls of the perspectives, and integrate the debate on these two levels. Our synthesis concludes that when a society has a robust division of moral labour in place, the responsibility of a corporation may be economic (as suggested under the economic perspective) without jeopardising democracy and sustainability (as reported under the critical perspective). Moreover, the economic role of corporations neither signifies the absence of deliberative democratic mechanisms nor business practices extending beyond compliance (as called for under the politico-ethical perspective). The study underscores the value of integrating different perspectives and multiple levels of analysis to present comprehensive descriptions and prescriptions of the responsibility phenomenon

    Saturation Vapor Pressures and Transition Enthalpies of Low-Volatility Organic Molecules of Atmospheric Relevance: From Dicarboxylic Acids to Complex Mixtures

    Full text link

    Keywords and Cultural Change: Frame Analysis of Business Model Public Talk, 1975–2000

    Full text link
    • …
    corecore