713 research outputs found

    Star-forming galaxies versus low- and high-excitation radio AGN in the VLA-COSMOS 3GHz Large Project

    Get PDF
    We study the composition of the faint radio population selected from the VLA-COSMOS 3GHz Large Project, a radio continuum survey performed at 10 cm wavelength. The survey covers the full 2 square degree COSMOS field with mean rms2.3rms\sim2.3 μ\muJy/beam, cataloging 10,899 source components above 5×rms5\times rms. By combining these radio data with UltraVISTA, optical, near-infrared, and Spitzer/IRAC mid-infrared data, as well as X-ray data from the Chandra Legacy, and Chandra COSMOS surveys, we gain insight into the emission mechanisms within our radio sources out to redshifts of z5z\sim5. From these emission characteristics we classify our souces as star forming galaxies or AGN. Using their multi-wavelength properties we further separate the AGN into sub-samples dominated by radiatively efficient and inefficient AGN, often referred to as high- and low-excitation emission line AGN. We compare our method with other results based on fitting of the sources' spectral energy distributions using both galaxy and AGN spectral models, and those based on the infrared-radio correlation. We study the fractional contributions of these sub-populations down to radio flux levels of \sim10 μ\muJy. We find that at 3 GHz flux densities above \sim400 μ\muJy quiescent, red galaxies, consistent with the low-excitation radio AGN class constitute the dominant fraction. Below densities of \sim200 μ\muJy star-forming galaxies begin to constitute the largest fraction, followed by the low-excitation, and X-ray- and IR-identified high-excitation radio AGN.Comment: 7 pages, 3 figures, The many facets of extragalactic radio surveys: towards new scientific challenges, Bologna 20-23 October 201

    Аналіз впливу індуктивності навантаження на спричинені «мертвим часом» нелінійні спотворення підсилювача класу D

    Get PDF
    Goal. Analysis of the effect of load inductance at the output of the class D amplifier for different values of the duration of «dead time» and assessment of the adequacy of existing mathematical models for calculating the THD at the output of the amplifier depending on the duration of «dead time». Methodology. The study of the effect of «dead time» on the THD was performed using a computer model of the half-bridge converter board EPC9035 from Efficient Power Conversion. This board contains GaN transistors EPC2022 eGaN®, the corresponding control driver and other necessary elements for operation. The use of GaN transistors has made it possible to investigate the operation in a wide range of frequent switching, both to control the motor and to amplify the audio signal. Results. It is established that the value of load inductance affects the level of nonlinear distortions caused by «dead time». At inductance values that provide a constant sign of the output current, a difference arises between the duration of the input and output pulses, which increases the THD. At inductance values, when the choke current changes sign during a pulse, there is no error between the duration of the input and output pulses. Changing the inductance changes the relationship between the error signal and the non-error signal. THD changes accordingly. At high conversion frequencies, the voltage spikes caused by the choke current through the built-in diodes during the dead time are partially compensated by overcharging the output capacitance of the transistors, which also reduces harmonic distortion. Originality. For the first time, the value of the THD at the outlets in the fallowness of the different indices of the inductance of the choke and the theoretical calculation of the value in the results of the computer model was obtained. Practical significance. The dependence of the THD values on the inductance of the choke for converters with a switching frequency range from 1 kHz to 400 kHz, which allows them to be used both to control the motor and to amplify the audio signal.В роботі досліджено вплив індуктивності навантаження підсилювача класу D на значення коефіцієнту гармонічних спотворень (КГС) на виході для різних значень тривалості «мертвого часу» або вимкненого стану вихідних транзисторів. Оцінена адекватність існуючих математичних моделей для розрахунку КГС на виході підсилювача в залежності від тривалості «мертвого часу». Наведено результати комп’ютерного моделювання підсилювача класу D та досліджено значення КГС на виході в залежності від різних номіналів індуктивності вихідного дроселя. Виконано порівняння теоретично обчислених значень з результатами комп’ютерного моделювання. В результаті дослідження встановлено, що КГС, спричинений наявністю «мертвого часу» залежить від індуктивності навантаження. Отриманий у результаті моделювання КГС співпадає з розрахованим за формулою тільки для певних значень індуктивності навантаження. В моделі використано GaN транзистори, що дозволило дослідити роботу підсилювача у широкому діапазоні частот перемикання
    corecore