155 research outputs found

    Perioperative fluid overload increases anastomosis thrombosis in the free TRAM flap used for breast reconstruction

    Get PDF
    To increase perfusion pressure with vasoactive drugs may be in conflict with the opinion of the reconstructive surgeon who maintains that the systemic administration of vasoactive agents causes vasoconstriction of the pedicle artery and the microvasculature. In free flap surgery, deliberate fluid therapy is used with a minimum of vasoactive drugs. This retrospective study was performed to analyse the perioperative fluid therapy, its effect on hemodynamic parameters and on the outcome of free flap surgery. One hundred and four patients were included in this retrospective study. The muscle sparing free transverse rectus abdominis myocutaneous flap was used for breast reconstruction. Perioperative hemodynamic data was used for this study. Twenty-seven patients had one or two complications requiring return to the operating room (OR). Two cases returned to the OR because of postoperative bleeding; in 11 patients, the anastomosis was revised. The reason for surgery in the latter group was venous stasis, due to thrombus formation at the venous anastomosis. The volume of fluid therapy was significantly higher in patients who returned to the OR due to thrombus formation at the anastomosis. Based on the results of this study, restricted intravenous fluid therapy or guided fluid therapy is recommended. Invasive monitoring such as central venous pressure and invasive arterial monitoring is recommended. Fluid loss should be replaced, and fluid overload should be avoided when the breast is reconstructed using free-tissue transfers

    Three-dimensional mapping of fluorescent dye using a scanning, depth-resolving airborne lidar

    Get PDF
    Author Posting. © American Meteorological Society, 2007. This article is posted here by permission of American Meteorological Society for personal use, not for redistribution. The definitive version was published in Journal of Atmospheric and Oceanic Technology 24 (2007): 1050-1065, doi:10.1175/JTECH2027.1.Results are presented from a pilot study using a fluorescent dye tracer imaged by airborne lidar in the ocean surface layer on spatial scales of meters to kilometers and temporal scales of minutes to hours. The lidar used here employs a scanning, frequency-doubled Nd:YAG laser to emit an infrared (1064 nm) and green (532 nm) pulse 6 ns in duration at a rate of 1 kHz. The received signal is split to infrared, green, and fluorescent (nominally 580–600 nm) channels, the latter two of which are used to compute absolute dye concentration as a function of depth and horizontal position. Comparison of dye concentrations inferred from the lidar with in situ fluorometry measurements made by ship shows good agreement both qualitatively and quantitatively for absolute dye concentrations ranging from 1 to >10 ppb. Uncertainties associated with horizontal variations in the natural seawater attenuation are approximately 1 ppb. The results demonstrate the ability of airborne lidar to capture high-resolution three-dimensional “snapshots” of the distribution of the tracer as it evolves over very short time and space scales. Such measurements offer a powerful observational tool for studies of transport and mixing on these scales.Support was provided by the Cecil H. and Ida M. Green Technology Innovation Fund under Grant 27001545, the Office of Naval Research Grant N00014-01-1-0984, and the Woods Hole Oceanographic Institution Coastal Ocean Institute

    Use cases for obstacle detection and track intrusion detection systems in the context of new generation of railway traffic management systems

    Get PDF
    In this paper, the concept of Obstacle Detection and Track Intrusion Detection (OD&TID) systems related to the operation of trains is introduced, along with a potential concept for such a system. The main focus of the work presented here is the identification and description of system requirements and Use Cases (UC), their detailed classification, including general UCs for mainline railway and UCs specific to freight, as well as an analysis of the UCs and of the method used. The identified UCs have been organised with respect to the mode of operation, Grade of Automation (GoA), and operating conditions. The UCs were further analysed in different UC scenarios, including the pre-conditions, system response, actions made by OD&TID and associated systems and the post use conditions of the scenarios. The priority for implementation and complexity of each UC are discussed with respect to the probability of scenario occurrence and required interfaces. This work has been carried out as part of the process to evaluate implementation constraints, risks and requirements, and the operational scenarios of the OD&TID developed within the EU-funded Shift2Rail project SMART2, which aims to design and develop a prototype OD&TID system

    Ragweed pollen and allergic symptoms in children: Results from a three-year longitudinal study

    Get PDF
    Common ragweed is a highly allergenic invasive species in Europe, expected to become widespread under climate change. Allergy to ragweed manifests as eye, nasal and lung symptoms, and children may retain these throughout life. The dose-response relationship between symptoms and pollen concentrations is unclear. We undertook a longitudinal study, assessing the association between ragweed pollen concentration and allergic eye, nasal and lung symptoms in children living under a range of ragweed pollen concentrations in Croatia. Over three years, 85 children completed daily diaries, detailing allergic symptoms alongside daily location, activities and medication, resulting in 10,130 individual daily entries. The daily ragweed pollen concentration for the children's locations was obtained, alongside daily weather and air pollution. Parents completed a home/lifestyle/medical questionnaire. Generalised Additive Mixed Models established the relationship between pollen concentrations and symptoms, alongside other covariates. Eye symptoms were associated with mean daily pollen concentration over four days (day of symptoms plus 3 previous days); 61 grains/m3/day (95%CI: 45, 100) was the threshold at which 50% of children reported symptoms. Nasal symptoms were associated with mean daily pollen concentration over 12 days (day of symptoms plus 11 previous days); the threshold for 50% of children reporting symptoms was 40 grains/m3/day (95%CI: 24, 87). Lung symptoms showed a relationship with mean daily pollen concentration over 19 days (day of symptoms plus 18 previous days), with a threshold of 71 grains/m3/day (95%CI: 59, 88). Taking medication on the day of symptoms showed higher odds, suggesting responsive behaviour. Taking medication on the day prior to symptoms showed lower odds of reporting, indicating preventative behaviour. Different symptoms in children demonstrate varying dose-response relationships with ragweed pollen concentrations. Each symptom type responded to pollen exposure over different time periods. Using medication prior to symptoms can reduce symptom presence. These findings can be used to better manage paediatric ragweed allergy symptoms

    Genetic polymorphism of the serine rich antigen N-terminal region in Plasmodium falciparum field isolates from Brazil

    Full text link
    In this work we investigated the frequency of polymorphism in exon II of the gene encoding most of the amino-terminal region of the serine rich antigen (SERA) in Plasmodium falciparum field samples. The blood samples were colleted from P. falciparum infected individuals in three areas of the Brazilian Amazon. Two fragments have been characterized by polymerase chain reaction: one of 175 bp corresponding to the repeat region with 5 octamer units and one other of 199 bp related to the 6 repeat octamer units of SERA protein. The 199 bp fragment was the predominant one in all the studied areas. The higher frequency of this fragment has not been described before and could be explained by an immunological selection of the plasmodial population in the infected individuals under study. Since repeat motifs in the amino-terminal region of SERA contain epitopes recognized by parasite-inhibitor antibodies, data reported here suggest that the analysis of the polymorphism of P. falciparum isolates in different geographical areas is a preliminary stage before the final drawing of an universal vaccine against malaria can be reached

    Algometry with a clothes peg compared to an electronic pressure algometer: a randomized cross-sectional study in pain patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hypersensitivity of the central nervous system is widely present in pain patients and recognized as one of the determinants of chronic pain and disability. Electronic pressure algometry is often used to explore aspects of central hypersensitivity. We hypothesized that a simple pain provocation test with a clothes peg provides information on pain sensitivity that compares meaningfully to that obtained by a well-established electronic pressure algometer. "Clinically meaningful" was defined as a medium (r = 0.3-0.5) or high (r > 0.5) correlation coefficient according to Cohen's conventions.</p> <p>Methods</p> <p>We tested 157 in-patients with different pain types. A calibrated clothes peg was applied for 10 seconds and patients rated the pain intensity on a 0 to 10 numerical rating scale. Pressure pain detection threshold (PPdt) and pressure pain tolerance threshold (PPtt) were measured with a standard electronic algometer. Both methods were performed on both middle fingers and ear lobes. In a subgroup of 47 patients repeatability (test-retest reliability) was calculated.</p> <p>Results</p> <p>Clothes peg values correlated with PPdt values for finger testing with r = -0.54 and for earlobe testing with r = -0.55 (all p-values < 0.001). Clothes peg values also correlated with PPtt values for finger testing with r = -0.55 (p < 0.001). Test-retest reliability (repeatability) showed equally stable results for clothes peg algometry and the electronic algometer (all r-values > 0.89, all p-values < 0.001).</p> <p>Conclusions</p> <p>Information on pain sensitivity provided by a calibrated clothes peg and an established algometer correlate at a clinically meaningful level.</p

    Evaluation of allelic forms of the erythrocyte binding antigen 175 (EBA-175) in Plasmodium falciparum field isolates from Brazilian endemic area

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The <it>Plasmodium falciparum </it>Erythrocyte Binding Antigen-175 (EBA-175) is an antigen considered to be one of the leading malaria vaccine candidates. EBA-175 mediates sialic acid-dependent binding to glycophorin A on the erythrocytes playing a crucial role during invasion of the <it>P. falciparum </it>in the host cell. Dimorphic allele segments, termed C-fragment and F-fragment, have been found in high endemicity malaria areas and associations between the dimorphism and severe malaria have been described. In this study, the genetic dimorphism of EBA-175 was evaluated in <it>P. falciparum </it>field isolates from Brazilian malaria endemic area.</p> <p>Methods</p> <p>The study was carried out in rural villages situated near Porto Velho, Rondonia State in the Brazilian Amazon in three time points between 1993 and 2008. The allelic dimorphism of the EBA-175 was analysed by Nested PCR.</p> <p>Results</p> <p>The classical allelic dimorphism of the EBA-175 was identified in the studied area. Overall, C-fragment was amplified in a higher frequency than F-fragment. The same was observed in the three time points where C-fragment was observed in a higher frequency than F-fragment. Single infections (one fragment amplified) were more frequent than mixed infection (two fragments amplified).</p> <p>Conclusions</p> <p>These findings confirm the dimorphism of EBA175, since only the two types of fragments were amplified, C-fragment and F-fragment. Also, the results show the remarkable predominance of CAMP allele in the studied area. The comparative analysis in three time points indicates that the allelic dimorphism of the EBA-175 is stable over time.</p
    corecore