462 research outputs found

    Il corpo a corpo di Sergio Luzzatto con la Resistenza

    Get PDF
    Il saggio discute analiticamente e criticamente il volume di Sergio Luzzatto, Partigia, prendendo in esame sia l'impostazione del lavoro, sia l'uso delle fonti e l'analisi dei testi d Primo Levi proposta da Luzzatto, sia il contesto storiografico e politico-culturale in cui si inserisce

    Fiber Post Removal: Comparative Study Using a New Post Concept

    Get PDF
    Objectives: To evaluate the time required to remove endodontic posts made of quartz and glass fibers, and compare them to a new glass fiber post designed for easy removal on the basis of efficiency and tooth damages. Methods: 40 human single-rooted teeth were treated endodontically and randomly assigned to four fiber posts groups: 1) was restored with Premier#90 (Innotech); 2) with DT#2 Lightpost (Dentsply); 3) with Unicore#3 (Ultradent); 4) with a special, soft-cored “S” glass fiber post ER-Prosthetic#3 (Overfibers). An impression of the canal was taken prior post cementation. The posts were luted with Panavia F and adhesive (Kuraray). All the specimens were mounted in a dental simulation unit to reproduce the difficulty of clinical conditions. The fiber posts were removed using a diamond bur /Gates and Largo reamer combination. The teeth were examined radiographycally 2 times seeking for cement, fiber composite debris and tooth damage. After post removal, another impression of the canal was taken for each tooth to evaluate the canal enlargement. Then, the specimens were fractured and observed microscopically. Results: No significant differences were found among the conventional posts (groups 1-3) as regards removal time and dental tissue loss (Kruskal-Wallis, alpha=0.05). The new soft-core concept applied to the ER-Prosthetics allowed a mean rank removal time significantly lower (P=0.001) than the mean rank of group 1-3 posts (Dunn's test). The canal enlargement was significantly lower with ER posts. Root perforation occurred in groups 1 to 3, but none was recorded in group 4. Conclusion: Removal of posts avoiding dental tissue loss is a difficult task when performed in simulated clinical conditions. A new post type conceived to be removed safely in a short time was very effective to reduce the removal time without tooth damages. Further studies will be necessary to validate this new concept

    Fatigue failure and success rate of lithium disilicate table-tops as a function of cement thickness

    Get PDF
    Purpose: Under thin, partial coverage restoration the proper cement thickness to be clinically employed still remains an issue. The aim of this study was to determine the failure and success rates of simplified lithium disilicate occlusal veneers as a function of cement thickness. The null hypothesis was that cement thickness has no effect on the fatigue resistance. Methods: Sound human molars were severed in a plane parallel to the occlusal surface to create a flat dentin surface surrounded by enamel edges. Forty-five occlusal veneers 1.0 mm thick (IPS e.max CAD LT) were luted to the teeth with Multilink Automix resin cement, creating 3 experimental groups (n=15) with cement thicknesses of 50, 100, and 200 µm. The restorations were fatigue-cycled using a ball mill machine containing zirconia and stainless steel spheres. Twelve 60 min cycles were performed. Survival statistics were applied to “failure” and “success” events, comparing the three groups using a log-rank Mantel– Cox test and a log-rank test for trends (alpha = 0.05). Results: The failure and success rates were not significantly influenced by cement thickness (P = 0.137 and P = 0.872, respectively); thus, the null hypothesis was accepted. However, when log-rank test for trends was applied to failure events, the tendency to have less failures with increasing thicknesses was found statistically significant (P = 0.047). Conclusions: The cement thickness within the range adopted here did not have a significant effect on the failure or success rate of lithium disilicate occlusal veneers when exposed to randomized impact stresses generating fatigue phenomena

    Estupro de vulnerável: o estudo de caso do habeas corpus n° 105.533 e a aplicação da pena após o advento da lei 12.015/2009 sob o enfoque da psicologia criminal

    Get PDF
    Trata-se de trabalho sobre a questão que surgiu após o advento da Lei 12.015/09, a qual unificou os antigos crimes de atentado violento ao pudor e estupro em um único tipo penal. Eis que, com a vigência da nova norma, sobrevieram distintas posições doutrinárias e jurisprudenciais quanto ao tema, uma vez que, para alguns, a unificação se configura uma lei favorável ao réu enquanto para outros não se trata de norma benéfica, apenas mantendo a antiga denominação dos crimes em um único tipo. A análise da antiga e da nova redação do texto penal é de mera importância para o entendimento da mudança, bem como os diversos posicionamentos doutrinários e jurisprudenciais. No segundo ponto, há a abordagem da teoria psicológica do criminoso, quais as causas e motivos que o levam a cometer reiteradamente o crime de estupro de vulnerável, bem como os danos psíquicos deixados em suas vítimas e também as outras formas de prisão diferenciada aos indivíduos afetados. Por último, para o fechamento dos estudos anteriormente verificados, são analisados dois casos contrapostos, conforme o julgamento dos recursos de cada ação

    Effect of root canal preparation, type of endodontic post and mechanical cycling on root fracture strength

    Get PDF
    Objective: To evaluate the impact of the type of root canal preparation, intraradicular post and mechanical cycling on the fracture strength of roots. Material and Methods: eighty human single rooted teeth were divided into 8 groups according to the instruments used for root canal preparation (manual or rotary instruments), the type of intraradicular post (fiber posts- FRC and cast post and core- CPC) and the use of mechanical cycling (MC) as follows: Manual and FRC; Manual, FRC and MC; Manual and CPC; Manual, CPC and MC; Rotary and FRC; Rotary, FRC and MC; Rotary and CPC; Rotary, CPC and MC. The filling was performed by lateral compactation. All root canals were prepared for a post with a 10 mm length, using the custom #2 bur of the glass fiber post system. For mechanical cycling, the protocol was applied as follows: an angle of incidence of 45°, 37°C, 88 N, 4 Hz, 2 million pulses. All groups were submitted to fracture strength test in a 45° device with 1 mm/ min cross-head speed until failure occurred. Results: The 3-way ANOVA showed that the root canal preparation strategy (

    Effect of root canal preparation, type of endodontic post and mechanical cycling on root fracture strength

    Get PDF
    Objective: To evaluate the impact of the type of root canal preparation, intraradicular post and mechanical cycling on the fracture strength of roots. Material and Methods: eighty human single rooted teeth were divided into 8 groups according to the instruments used for root canal preparation (manual or rotary instruments), the type of intraradicular post (fiber posts- FRC and cast post and core- CPC) and the use of mechanical cycling (MC) as follows: Manual and FRC; Manual, FRC and MC; Manual and CPC; Manual, CPC and MC; Rotary and FRC; Rotary, FRC and MC; Rotary and CPC; Rotary, CPC and MC. The filling was performed by lateral compactation. All root canals were prepared for a post with a 10 mm length, using the custom #2 bur of the glass fiber post system. For mechanical cycling, the protocol was applied as follows: an angle of incidence of 45°, 37°C, 88 N, 4 Hz, 2 million pulses. All groups were submitted to fracture strength test in a 45° device with 1 mm/ min cross-head speed until failure occurred. Results: The 3-way ANOVA showed that the root canal preparation strategy (

    Selective adhesive luting: A novel technique for improving adhesion achieved by universal resin cements

    Get PDF
    Objective: We aimed to introduce the concept of "Selective adhesive luting-SAL" which is explained through clinical steps and supported by preliminary laboratory evidence. Clinical considerations: Cementation with rubber dam is difficult to perform in case of short abutment teeth and/or subgingival crown margins. By means of universal resin cements/universal adhesive systems, which can be employed in self-adhesive as well as adhesive luting procedures, this paper presents a novel technique allowing clinicians to perform reliable cementation where rubber dam isolation is difficult. The SAL technique entails the application of a universal adhesive system only on easily accessible abutment surfaces, enabling simultaneous adhesive and self-adhesive luting in different portions of the abutment. The SAL clinical workflow is explained through prosthodontic rehabilitation of maxillary right central incisor affected by microdontia and restored with a lithium-disilicate crown. Furthermore, our laboratory microshear bond strength study supports the rationale behind SAL application demonstrating higher bond strength even when the adhesive resin is placed only on one portion of the cementation substrate. Clinical significance: This article advocates the application of SAL technique in clinical situations where effective adhesive luting is uncertain, since it can improve the adhesion between the tooth and universal resin cements

    Fracture load and shear stress of prefabricated glass fiber posts

    Get PDF
    Aim: This study evaluated the fracture load and pattern failure of different prefabricated glass fiber posts (GFPs) of the same diameter. Methods: Seventy-eight (n=13 for six groups) GFPs of 1.6 mm coronal diameter of different brands were evaluated— Exacto (Angelus), Power Post (BM4), White Post DC (FGM), HiRem (Overfibers), MAQ (Maquira), and SD (Supordont). The posts were subjected to fracture load testing (45° of inclination and 1 mm/min until fracture). Each factor (load (N) and shear stress (MPa)) was analyzed separately using one-way ANOVA followed by the Tukey test (α=0.05). Results: The type of failure was evaluated on a stereomicroscope (×10). The Power Post samples presented higher values of fracture load (p<0.001) followed by Maquira fiber post, White Post , HiRem, Superpost, and the Exacto posts. The failure pattern observed was intralaminar mode II in-plane shear, such as a failure occur parallel to fibers. Conclusion: Despite the same diameter of GFPs, the fracture load and shear resistance were brand-dependent
    • …
    corecore