263 research outputs found

    Evidence on continuous flow peritoneal dialysis: A review

    Get PDF
    Clinical application of continuous flow peritoneal dialysis (CFPD) has been explored since the 1960s, but despite anticipated clinical benefits, CFPD has failed to gain a foothold in clinical practice, among others due to the typical use of two catheters (or a dual-lumen catheter) and large dialysate volumes required per treatment. Novel systems applying CFPD via the existing single-lumen catheter using rapid dialysate cycling may solve one of these hurdles. Novel on-demand peritoneal dialysate generation systems and sorbent-based peritoneal dialysate regeneration systems may considerably reduce the storage space for peritoneal dialysate and/or the required dialysate volume. This review provides an overview of current evidence on CFPD in vivo. The available (pre)clinical evidence on CFPD is limited to case reports/series with inherently nonuniform study procedures, or studies with a small sample size, short follow-up, and no hard endpoints. Small solute clearance appears to be higher in CFPD compared to conventional PD, in particular at dialysate flows ≥100 mL/min using two single-lumen catheters or a double-lumen catheter. Results of CFPD using rapid cycling via a single-lumen catheter are too preliminary to draw any conclusions. Continuous addition of glucose to dialysate with CFPD appears to be effective in reducing the maximum intraperitoneal glucose concentration while increasing ultrafiltration efficiency (mL/g absorbed glucose). Patient tolerance may be an issue since abdominal discomfort and sterile peritonitis were reported with continuous circulation of the peritoneal dialysate. Thus, well-designed clinical trials of longer duration and larger sample size, in particular applying CFPD via the existing catheter, are urgently required

    Evaluation of a system for sorbent-assisted peritoneal dialysis in a uremic pig model

    Get PDF
    A system for sorbent-assisted peritoneal dialysis (SAPD) has been developed that continuously recirculates dialysate via a tidal mode using a single-lumen peritoneal catheter with the regeneration of spent dialysate by means of sorbents. SAPD treatment may improve plasma clearance by the maintenance of a high plasma-to-dialysate concentration gradient and by increasing the mass transfer area coefficient (MTAC) of solutes. The system is designed for daily 8-hr treatment (12 kg, nighttime system). A wearable system (2.3 kg, daytime system) may further enhance the clearance of phosphate and organic waste solutes during the day. Uremic pigs (n = 3) were treated with the day- (n = 3) and nighttime system (n = 15) for 4-8 hr per treatment. Plasma clearance (Cl), MTAC, and total mass transport (MT) of urea, creatinine, phosphate, and potassium were compared with a static dwell (n = 28). Cl, MTAC, and MT of urea, creatinine, phosphate, and potassium were low in the pig as compared to humans due to the pig's low peritoneal transport status and could be enhanced only to a limited extent by SAPD treatment compared with a static dwell (nighttime system: Cl urea: Ă—1.5 (p = .029), Cl creatinine: Ă—1.7 (p = .054), Cl phosphate: Ă—1.5 (p = .158), Cl potassium: Ă—1.6 (p = .011); daytime system: Cl creatinine: Ă—2.7 (p = .040), Cl phosphate: Ă—2.2 (p = .039)). Sorbent-assisted peritoneal dialysis treatment in a uremic pig model is safe and enhances small solute clearance as compared to a static dwell. Future studies in humans or animal species with higher peritoneal transport should elucidate whether our SAPD system enhances clearance to a clinically relevant extent as compared to conventional PD

    Study of Spin and Decay-Plane Correlations of W Bosons in the e+e- -> W+W- Process at LEP

    Get PDF
    Data collected at LEP at centre-of-mass energies \sqrt(s) = 189 - 209 GeV are used to study correlations of the spin of W bosons using e+e- -> W+W- -> lnqq~ events. Spin correlations are favoured by data, and found to agree with the Standard Model predictions. In addition, correlations between the W-boson decay planes are studied in e+e- -> W+W- -> lnqq~ and e+e- -> W+W- -> qq~qq~ events. Decay-plane correlations, consistent with zero and with the Standard Model predictions, are measured

    Ultrarelativistic sources in nonlinear electrodynamics

    Get PDF
    The fields of rapidly moving sources are studied within nonlinear electrodynamics by boosting the fields of sources at rest. As a consequence of the ultrarelativistic limit the delta-like electromagnetic shock waves are found. The character of the field within the shock depends on the theory of nonlinear electrodynamics considered. In particular, we obtain the field of an ultrarelativistic charge in the Born-Infeld theory.Comment: 10 pages, 3 figure

    Search for Branons at LEP

    Full text link
    We search, in the context of extra-dimension scenarios, for the possible existence of brane fluctuations, called branons. Events with a single photon or a single Z-boson and missing energy and momentum collected with the L3 detector in e^+ e^- collisions at centre-of-mass energies sqrt{s}=189-209$ GeV are analysed. No excess over the Standard Model expectations is found and a lower limit at 95% confidence level of 103 GeV is derived for the mass of branons, for a scenario with small brane tensions. Alternatively, under the assumption of a light branon, brane tensions below 180 GeV are excluded

    Measurement of the Cross Section for Open-Beauty Production in Photon-Photon Collisions at LEP

    Get PDF
    The cross section for open-beauty production in photon-photon collisions is measured using the whole high-energy and high-luminosity data sample collected by the L3 detector at LEP. This corresponds to 627/pb of integrated luminosity for electron-positron centre-of-mass energies from 189GeV to 209GeV. Events containing b quarks are identified through their semi-leptonic decay into electrons or muons. The e+e- -> e+e-b b~X cross section is measured within our fiducial volume and then extrapolated to the full phase space. These results are found to be in significant excess with respect to Monte Carlo predictions and next-to-leading order QCD calculations

    Search for Branons at LEP

    Get PDF
    We search, in the context of extra-dimension scenarios, for the possible existence of brane fluctuations, called branons. Events with a single photon or a single Z-boson and missing energy and momentum collected with the L3 detector in e^+ e^- collisions at centre-of-mass energies sqrt{s}=189-209$ GeV are analysed. No excess over the Standard Model expectations is found and a lower limit at 95% confidence level of 103 GeV is derived for the mass of branons, for a scenario with small brane tensions. Alternatively, under the assumption of a light branon, brane tensions below 180 GeV are excluded

    Measurement of Exclusive rho^0 rho^0 Production in Two-Photon Collisions at High Q^2 at LEP

    Full text link
    Exclusive rho rho production in two-photon collisions involving a single highly virtual photon is studied with data collected at LEP at centre-of-mass energies 89GeV < \sqrt{s} < 209GeV with a total integrated luminosity of 854.7pb^-1 The cross section of the process gamma gamma^* -> rho rho is determined as a function of the photon virtuality, Q^2 and the two-photon centre-of-mass energy, Wgg, in the kinematic region: 1.2GeV^2 < Q^2 < 30GeV^2 and 1.1GeV < Wgg < 3GeV

    K0s K0s Final State in Two-Photon Collisions and Implications for Glueballs

    Get PDF
    The K0s K0s final state in two-photon collisions is studied with the L3 detector at LEP. The mass spectrum is dominated by the formation of the f_2'(1525) tensor meson in the helicity-two state with a two-photon width times the branching ratio into K Kbar of 76 +- 6 +- 11 eV. A clear signal for the formation of the f_J(1710) is observed and it is found to be dominated by the spin-two helicity-two state. No resonance is observed in the mass region around 2.2 GeV and an upper limit of 1.4 eV at 95% C.L. is derived for the two-photon width times the branching ratio into K0s K0s for the glueball candidate xi(2230)
    • …
    corecore