    Aortic Root Enlargement or Sutureless Valve Implantation?

    Get PDF
    Aortic valve replacement (AVR) in patients with a small aortic annulus is a challenging issue. The importance of prosthesis–patient mismatch (PPM) post aortic valve replacement (AVR) is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively and keeping in mind that often some comorbidities are present in old patients with small aortic root, the Perceval S suturelles valve implantation could be a perfect solution. The Perceval sutureless bioprosthesis provides reasonable hemodynamic performance avoiding the PPM and providing the maximum of aortic orifice area. We would like to see in the near future the role of the aortic root enlargement techniques in the era of surgical implantation of the sutureless valve (SAVR) and the transcatheter valve implantation (TAVI)

    Simultaneously performed off-pump coronary artery bypass grafting and colectomy: a case report

    Get PDF
    This is written so as to report the case of a 71-year-old male with a diagnosis of sigmoid adenocarcinoma accompanied by severe coronary artery disease and unstable angina, which was subject to simultaneous surgical treatment. The patient initially underwent an off-pump coronary artery revascularization in order to avoid the complications of cardiopulmonary bypass, providing the opportunity of a colectomy at the same time with the use of safe surgical means. Our case suggests that performing an off-pump bypass procedure prior to cancer surgery can be an appropriate course of action in carefully selected cases

    Modulation Techniques for Biomedical Implanted Devices and Their Challenges

    Get PDF
    Implanted medical devices are very important electronic devices because of their usefulness in monitoring and diagnosis, safety and comfort for patients. Since 1950s, remarkable efforts have been undertaken for the development of bio-medical implanted and wireless telemetry bio-devices. Issues such as design of suitable modulation methods, use of power and monitoring devices, transfer energy from external to internal parts with high efficiency and high data rates and low power consumption all play an important role in the development of implantable devices. This paper provides a comprehensive survey on various modulation and demodulation techniques such as amplitude shift keying (ASK), frequency shift keying (FSK) and phase shift keying (PSK) of the existing wireless implanted devices. The details of specifications, including carrier frequency, CMOS size, data rate, power consumption and supply, chip area and application of the various modulation schemes of the implanted devices are investigated and summarized in the tables along with the corresponding key references. Current challenges and problems of the typical modulation applications of these technologies are illustrated with a brief suggestions and discussion for the progress of implanted device research in the future. It is observed that the prime requisites for the good quality of the implanted devices and their reliability are the energy transformation, data rate, CMOS size, power consumption and operation frequency. This review will hopefully lead to increasing efforts towards the development of low powered, high efficient, high data rate and reliable implanted devices

    Cardiac surgery in a patient with retroperitoneal fibrosis and heart valvulopathy, both due to pergolide medication for Parkinson's disease

    Get PDF
    Retroperitoneal fibrosis is best described as a chronic inflammatory process which may be idiopathic, but can rarely be brought about by medications, such as pergolide, used for treating Parkinson's disease. Pergolide can produce a fibrotic process in heart valves, resulting in valve insufficiency in up to 25% of cases. Herein we describe the case of a 68-year-old man who received pergolide for 2 years for Parkinson's disease. The patient developed retroperitoneal fibrosis resulting in renal failure from ureteral obstruction necessitating ureteral stenting, as well as significant aortic and mitral valve insufficiency. He successfully underwent surgery for combined aortic valve, mitral valve and ascending aorta replacement because of severe valve insufficiency and dilated (d = 5.8 cm) ascending aorta. Retroperitoneal fibrosis improved with pergolide cessation and corticosteroid treatment. This is the second case reported in the literature, of a patient who had double valve and ascending aorta replacement surgery because he suffered from this rare but serious adverse effect of dopamine agonists used for managing Parkinson's disease

    "The non-ischemic repair" as a safe alternative method for repair of anterior post-infarction VSD

    Get PDF
    Patient's myocardium with post-infarction ventricular septum defect (VSD) is characterized by severe dysfunction. The "additive ischemia" caused by the operating process of cross-clamp ischemia and reperfusion injury, has a significant aggravation to the myocardium and overall negative impact to patient's outcome. We present a useful, safe and advantageous methodology in order to abolish "the toxic phase" of ischemia-reperfusion which is adopted by most as the "classic repair method" of myocardial protection. This abolition is in our opinion, particularly beneficial in order to reverse postoperatively the Low Cardiac Output Syndrome (LOS) and achieve better short and long term results. By using this method we avoid the aortic occlusion, the use of systematic hypothermia and any cardioplegic arrest. Furthermore, the total cardio-pulmonary bypass (CPB) time is significantly reduced, tissue debridement and stitching is much easier and safer. We think the method is applicable for every anterior and apical case of post-infarction septum rupture. After application of method in 3 patients with anterior post-myocardial infarction VSD, we are convinced that the patient will have a better postoperative haemodynamic condition and therefore a better outcome

    Acute left main coronary artery thrombosis due to cocaine use

    Get PDF
    It is common knowledge that cocaine has been linked to the development of various acute and chronic cardiovascular complications including acute coronary syndromes. We present a young, male patient, drug abuser who underwent CABG due to anterolateral myocardial infarction. Our presentation is one of the very rare cases reported in literature regarding acute thrombosis of left main coronary artery related to cocaine use, in a patient with normal coronary arteries, successfully operated. Drug-abusers seem to have increased mortality and morbidity after surgery and high possibility for stent thrombosis after percoutaneous coronary interventions, because of their usually terrible medical compliance and coexistent several problems of general health. There are no specific guidelines about treatment of thrombus formation in coronary arteries, as a consequence of cocaine use. So, any decision making concerning the final treatment of these patient is a unique and individualized approach. We strongly recommend that all these patients should be treated surgically, especially patients with thrombus into the left main artery

    Helicoidal surfaces rotating/translating under the mean curvature flow

    Get PDF
    We describe all possible self-similar motions of immersed hypersurfaces in Euclidean space under the mean curvature flow and derive the corresponding hypersurface equations. Then we present a new two-parameter family of immersed helicoidal surfaces that rotate/translate with constant velocity under the flow. We look at their limiting behaviour as the pitch of the helicoidal motion goes to 0 and compare it with the limiting behaviour of the classical helicoidal minimal surfaces. Finally, we give a classification of the immersed cylinders in the family of constant mean curvature helicoidal surfaces.Comment: 21 pages, 22 figures, final versio

    Intravenous levosimendan-norepinephrine combination during off-pump coronary artery bypass grafting in a hemodialysis patient with severe myocardial dysfunction

    Get PDF
    This the case of a 63 year-old man with end-stage renal disease (on chronic hemodialysis), unstable angina and significantly impaired myocardial contractility with low left ventricular ejection fraction, who underwent off-pump one vessel coronary bypass surgery. Combined continuous levosimendan and norepinephrine infusion (at 0.07 μg/kg/min and 0.05 μg/kg/min respectively) started immediately after anesthesia induction and continued for 24 hours. The levosimendan/norepinephrine combination helped maintain an appropriate hemodynamic profile, thereby contributing to uneventful completion of surgery and postoperative hemodynamic stability. Although levosimendan is considered contraindicated in ESRD patients, this case report suggests that combined perioperative levosimendan/norepinephrine administration can be useful in carefully selected hemodialysis patients with impaired myocardial contractility and ongoing myocardial ischemia, who undergo off-pump myocardial revascularization surgery

    Postoperative peri-axillary seroma following axillary artery cannulation for surgical treatment of acute type A aortic dissection

    Get PDF
    The arterial cannulation site for optimal tissue perfusion and cerebral protection during cardiopulmonary bypass (CPB) for surgical treatment of acute type A aortic dissection remains controversial. Right axillary artery cannulation confers significant advantages, because it provides antegrade arterial perfusion during cardiopulmonary bypass, and allows continuous antegrade cerebral perfusion during hypothermic circulatory arrest, thereby minimizing global cerebral ischemia. However, right axillary artery cannulation has been associated with serious complications, including problems with systemic perfusion during cardiopulmonary bypass, problems with postoperative patency of the artery due to stenosis, thrombosis or dissection, and brachial plexus injury. We herein present the case of a 36-year-old Caucasian man with known Marfan syndrome and acute type A aortic dissection, who had direct right axillary artery cannulation for surgery of the ascending aorta. Postoperatively, the patient developed an axillary perigraft seroma. As this complication has, not, to our knowledge, been reported before in cardiothoracic surgery, we describe this unusual complication and discuss conservative and surgical treatment options

    Baseline cerebral oximetry values in cardiac and vascular surgery patients: a prospective observational study

    Get PDF
    <p>Abstract</p> <p>Aim</p> <p>This study was conducted to evaluate baseline INVOS values and identify factors influencing preoperative baseline INVOS values in carotid endarterectomy and cardiac surgery patients.</p> <p>Methods</p> <p>This is a prospective observational study on 157 patients (100 cardiac surgery patients, 57 carotid endarterectomy patients). Data were collected on factors potentially related to baseline INVOS values. Data were analyzed with student's t-test, Chi-square, Pearson's correlation or Linear Regression as appropriate.</p> <p>Results</p> <p>100 cardiac surgery patients and 57 carotid surgery patients enrolled. Compared to cardiac surgery, carotid endarterectomy patients were older (71.05 ± 8.69 vs. 65.72 ± 11.04, P < 0.001), with higher baseline INVOS (P < 0.007) and greater stroke frequency (P < 0.002). Diabetes and high cholesterol were more common in cardiac surgery patients. Right side INVOS values were strongly correlated with left-side values in carotid (r = 0.772, P < 0.0001) and cardiac surgery patients (r = 0.697, P < 0.0001). Diabetes and high cholesterol were associated with significantly (P < 0.001) lower INVOS and smoking was associated with higher INVOS values in carotid, but not in cardiac surgery patients. Age, sex, CVA history, Hypertension, CAD, Asthma, carotid stenosis side and surgery side were not related to INVOS. Multivariate analysis showed that diabetes is strongly associated with lower baseline INVOS values bilaterally (P < 0.001) and explained 36.4% of observed baseline INVOS variability in carotid (but not cardiac) surgery.</p> <p>Conclusion</p> <p>Compared to cardiac surgery, carotid endarterectomy patients are older, with higher baseline INVOS values and greater stroke frequency. Diabetes and high cholesterol are associated with lower baseline INVOS values in carotid surgery. Right and left side INVOS values are strongly correlated in both patient groups.</p