25 research outputs found

    Cardiac sodium channel inhibition by lamotrigine: in vitro characterization and clinical implications

    Get PDF
    Lamotrigine, approved for use as an antiseizure medication (ASM) as well as the treatment of bipolar disorder, inhibits sodium channels in the brain to reduce repetitive neuronal firing and pathological release of glutamate. The shared homology of sodium channels and lack of selectivity associated with channel blocking agents can cause slowing of cardiac conduction and increased proarrhythmic potential. The Vaughan-Williams classification system differentiates sodium channel blockers using biophysical properties of binding. As such, Class Ib inhibitors including mexiletine do not slow cardiac conduction as measured by the electrocardiogram (ECG), at therapeutically relevant exposure. Our goal was to characterize the biophysical properties of NaV 1.5 block and to support the observed clinical safety of lamotrigine. We used HEK-293 cells stably expressing the hNaV 1.5 channel and voltage clamp electrophysiology to quantify the potency (IC50 ) against peak and late channel current, on-/off-rate binding kinetics, voltage-dependence and tonic block of the cardiac sodium channel by lamotrigine; and compared to clinically relevant Class Ia (quinidine), Ib (mexiletine) and Ic (flecainide) inhibitors. Lamotrigine blocked peak and late NaV 1.5 current at therapeutically relevant exposure, with rapid kinetics and biophysical properties similar to the Class Ib inhibitor mexiletine. However, no clinically meaningful prolongation in QRS or PR interval was observed in healthy subjects in a new analysis of a previously reported thorough QT clinical trial (SCA104648). In conclusion, the weak NaV 1.5 block and rapid kinetics do not translate into clinically relevant conduction slowing at therapeutic exposure and support the clinical safety of lamotrigine in patients suffering from epilepsy and bipolar disorder

    Blinded, multi-centre evaluation of drug-induced changes in contractility using human induced pluripotent stem cell-derived cardiomyocytes

    Get PDF
    Animal models are 78% accurate in determining whether drugs will alter contractility of the human heart. To evaluate the suitability of human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) for predictive safety pharmacology, we quantified changes in contractility, voltage, and/or Ca2+ handling in 2D monolayers or 3D engineered heart tissues (EHTs). Protocols were unified via a drug training set, allowing subsequent blinded multicenter evaluation of drugs with known positive, negative, or neutral inotropic effects. Accuracy ranged from 44% to 85% across the platform-cell configurations, indicating the need to refine test conditions. This was achieved by adopting approaches to reduce signal-to-noise ratio, reduce spontaneous beat rate to ≤ 1 Hz or enable chronic testing, improving accuracy to 85% for monolayers and 93% for EHTs. Contraction amplitude was a good predictor of negative inotropes across all the platform-cell configurations and of positive inotropes in the 3D EHTs. Although contraction- and relaxation-time provided confirmatory readouts forpositive inotropes in 3D EHTs, these parameters typically served as the primary source of predictivity in 2D. The reliance of these “secondary” parameters to inotropy in the 2D systems was not automatically intuitive and may be a quirk of hiPSC-CMs, hence require adaptations in interpreting the data from this model system. Of the platform-cell configurations, responses in EHTs aligned most closely to the free therapeutic plasma concentration. This study adds to the notion that hiPSC-CMs could add value to drug safety evaluation

    Scientific Engagement at FDA: A Report to the FDA Science Board from the Scientific Engagement Subcommittee

    Get PDF
    Maintaining active interactions with the broad external scientific community is vital for FDA to fulfill its expanding public health mission. It is essential for the Agency to be well positioned to address emerging areas of regulatory science and rapidly advancing technologies. Scientific engagement also helps FDA accomplish its mission by increasing awareness of FDA’s responsibilities and helping with the Agency’s critical recruitment and succession planning needs. FDA uses a range of mechanisms for scientific exchange. The Subcommittee was charged with considering: a. how FDA can improve its interface with the outside scientific community, particularly regarding public-private partnerships (PPPs) and fellowship programs and b. how the Reagan-Udall Foundation for FDA (RUF) can support both of these areas

    Biology-inspired microphysiological system approaches to solve the prediction dilemma of substance testing

    No full text
    The recent advent of microphysiological systems - microfluidic biomimetic devices that aspire to emulate the biology of human tissues, organs and circulation in vitro - is envisaged to enable a global paradigm shift in drug development. An extraordinary US governmental initiative and various dedicated research programs in Europe and Asia have led recently to the first cutting-edge achievements of human single-organ and multi-organ engineering based on microphysiological systems. The expectation is that test systems established on this basis would model various disease stages, and predict toxicity, immunogenicity, ADME profiles and treatment efficacy prior to clinical testing. Consequently, this technology could significantly affect the way drug substances are developed in the future. Furthermore, microphysiological system-based assays may revolutionize our current global programs of prioritization of hazard characterization for any new substances to be used, for example, in agriculture, food, ecosystems or cosmetics, thus, replacing laboratory animal models used currently. Thirty-six experts from academia, industry and regulatory bodies present here the results of an intensive workshop (held in June 2015, Berlin, Germany). They review the status quo of microphysiological systems available today against industry needs, and assess the broad variety of approaches with fit-for-purpose potential in the drug development cycle. Feasible technical solutions to reach the next levels of human biology in vitro are proposed. Furthermore, key organ-on-a-chip case studies, as well as various national and international programs are highlighted. Finally, a roadmap into the future is outlined, to allow for more predictive and regulatory-accepted substance testing on a global scale.publishe

    From in vivo to in vitro : The medical device testing paradigm shift

    No full text
    Amid growing efforts to advance the replacement, reduction, and refinement of the use of animals in research, there is a growing recognition that in vitro testing of medical devices can be more effective, both in terms of cost and time, and also more reliable than in vivo testing. Although the technological landscape has evolved rapidly in support of these concepts, regulatory acceptance of alternative testing methods has not kept pace. Despite the acceptance by regulators of some in vitro tests (cytotoxicity, gene toxicity, and some hemocompatibility assays), many toxicity tests still rely on animals (irritation, sensitization, acute toxicity, reproductive/developmental toxicity), even where other industrial sectors have already abandoned them. Bringing about change will require a paradigm shift in current approaches to testing - and a concerted effort to generate better data on risks to human health from exposure to leachable chemicals from medical devices, and to boost confidence in the use of alternative methods to test devices. To help advance these ideas, stir debate about best practices, and coalesce around a roadmap forward, the JHU-Center for Alternatives to Animal Testing (CAAT) hosted a symposium believed to be the first gathering dedicated to the topic of in vitro testing of medical devices. Industry representatives, academics, and regulators in attendance presented evidence to support the unique strengths and challenges associated with the approaches currently in use as well as new methods under development, and drew next steps to push the field forward from their presentations and discussion.publishe

    CVB1 release is polarized towards the epithelial lumen.

    No full text
    <p>(<b>A</b>) Graph showing quantitation of viral loads in the effluents of the apical (epithelial) versus basal (vascular) microchannels after basal infection of the gut chips with CVB1 at an MOI of 0.2 (*p < 0.05 compared to 0–6 hpi). (<b>B</b>) Confocal fluorescence micrographs of apically and basally infected gut chips at 6 and 24 hpi, showing horizontal sections at the base, middle and top of the villi (left to right columns). Infected chips were stained for CVB1 (green) and nuclei (blue); bar, 100 μm.</p
    corecore