12 research outputs found

    Radio frequency and DC high voltage breakdown of high pressure helium, argon, and xenon

    Get PDF
    Motivated by the possibility of guiding daughter ions from double beta decay events to single-ion sensors for barium tagging, the NEXT collaboration is developing a program of R&D to test radio frequency (RF) carpets for ion transport in high pressure xenon gas. This would require carpet functionality in regimes at higher pressures than have been previously reported, implying correspondingly larger electrode voltages than in existing systems. This mode of operation appears plausible for contemporary RF-carpet geometries due to the higher predicted breakdown strength of high pressure xenon relative to low pressure helium, the working medium in most existing RF carpet devices. In this paper we present the first measurements of the high voltage dielectric strength of xenon gas at high pressure and at the relevant RF frequencies for ion transport (in the 10 MHz range), as well as new DC and RF measurements of the dielectric strengths of high pressure argon and helium gases at small gap sizes. We find breakdown voltages that are compatible with stable RF carpet operation given the gas, pressure, voltage, materials and geometry of interest

    A Compact Dication Source for Ba2+^{2+} Tagging and Heavy Metal Ion Sensor Development

    Full text link
    We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cobalt samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba2+\mathrm{Ba^{2+}} ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb2+^{2+} and Cd2+^{2+} also demonstrated for this purpose

    Seguimiento de las guías españolas para el manejo del asma por el médico de atención primaria: un estudio observacional ambispectivo

    Get PDF
    Objetivo Evaluar el grado de seguimiento de las recomendaciones de las versiones de la Guía española para el manejo del asma (GEMA 2009 y 2015) y su repercusión en el control de la enfermedad. Material y métodos Estudio observacional y ambispectivo realizado entre septiembre del 2015 y abril del 2016, en el que participaron 314 médicos de atención primaria y 2.864 pacientes. Resultados Utilizando datos retrospectivos, 81 de los 314 médicos (25, 8% [IC del 95%, 21, 3 a 30, 9]) comunicaron seguir las recomendaciones de la GEMA 2009. Al inicio del estudio, 88 de los 314 médicos (28, 0% [IC del 95%, 23, 4 a 33, 2]) seguían las recomendaciones de la GEMA 2015. El tener un asma mal controlada (OR 0, 19, IC del 95%, 0, 13 a 0, 28) y presentar un asma persistente grave al inicio del estudio (OR 0, 20, IC del 95%, 0, 12 a 0, 34) se asociaron negativamente con tener un asma bien controlada al final del seguimiento. Por el contrario, el seguimiento de las recomendaciones de la GEMA 2015 se asoció de manera positiva con una mayor posibilidad de que el paciente tuviera un asma bien controlada al final del periodo de seguimiento (OR 1, 70, IC del 95%, 1, 40 a 2, 06). Conclusiones El escaso seguimiento de las guías clínicas para el manejo del asma constituye un problema común entre los médicos de atención primaria. Un seguimiento de estas guías se asocia con un control mejor del asma. Existe la necesidad de actuaciones que puedan mejorar el seguimiento por parte de los médicos de atención primaria de las guías para el manejo del asma. Objective: To assess the degree of compliance with the recommendations of the 2009 and 2015 versions of the Spanish guidelines for managing asthma (Guía Española para el Manejo del Asma [GEMA]) and the effect of this compliance on controlling the disease. Material and methods: We conducted an observational ambispective study between September 2015 and April 2016 in which 314 primary care physicians and 2864 patients participated. Results: Using retrospective data, we found that 81 of the 314 physicians (25.8%; 95% CI 21.3–30.9) stated that they complied with the GEMA2009 recommendations. At the start of the study, 88 of the 314 physicians (28.0%; 95% CI 23.4–33.2) complied with the GEMA2015 recommendations. Poorly controlled asthma (OR, 0.19; 95% CI 0.13–0.28) and persistent severe asthma at the start of the study (OR, 0.20; 95% CI 0.12–0.34) were negatively associated with having well-controlled asthma by the end of the follow-up. In contrast, compliance with the GEMA2015 recommendations was positively associated with a greater likelihood that the patient would have well-controlled asthma by the end of the follow-up (OR, 1.70; 95% CI 1.40–2.06). Conclusions: Low compliance with the clinical guidelines for managing asthma is a common problem among primary care physicians. Compliance with these guidelines is associated with better asthma control. Actions need to be taken to improve primary care physician compliance with the asthma management guidelines

    Determination of energy and exergy of waste heat in the industry of the Basque Country

    No full text
    The fuel costs and the impacts of energy use on the local environment make it necessary to reduce the consumption of energy of industrial processes. The use of waste heat recovery technologies is an effective way of achieving energy saving and therefore a reduction in energy consumption. In order to assess accurately the potential of waste heat recovery, it is necessary to know in detail the characteristics of the process streams. It is also necessary to examine in depth the different recovery technologies, to be able to integrate the set: waste heat-recovery technology-useful flow. Using the Basque Country industrial database and thermodynamic properties databases, the energy and exergy of waste heat have been determined for 10 industrial sectors of the Basque Country. The sectors have been classified according to their type into gases, liquid effluents and solid product streams, and also according to the temperature levels associated with them. In accordance with available data, energy content of waste heats amounts to 40% of total energy consumption in the industrial sectors of the Basque Country. Making a breakdown for types, we found that 33% of the energy of waste heat appears in the gas streams from combustion equipment, 27% is sensible heat of solid products, 16% is vapour, 11% liquid effluents and the rest appears as radiation, gases or by-products. More than half of this energy content appears at temperatures higher than 523 K. © 1997 Published by Elsevier Science Ltd

    Consensus statement on the diagnosis, management, and treatment of Angiodema mediated by Bradykinin. Part I. Classification, epidemiology, pathophysiology, genetics, clinical symptoms, and diagnosis

    Full text link
    Background: There are no Spanish guidelines or consensus statement on bradykinin-induced angioedema. Aim: To review the pathophysiology, genetics, and clinical symptoms of the different types of bradykinin-induced angioedema and to draft a consensus statement in light of currently available scientifi c evidence and the experience of experts. This statement will serve as a guideline to health professionals. Methods: The consensus was led by the Spanish Study Group on Bradykinin-Induced Angioedema (SGBA), a working group of the Spanish Society of Allergology and Clinical Immunology. A review was conducted of scientifi c papers on different types of bradykinin-induced angioedema (hereditary and acquired angioedema due to C1 inhibitor defi ciency, hereditary angioedema related to estrogens, angioedema induced by angiotensin-converting enzyme inhibitors). Several discussion meetings of the SGBA were held in Madrid to reach the consensus. Results: The pathophysiology, genetics, and clinical symptoms of the different types of angioedema are reviewed. Diagnostic approaches are discussed and the consensus reached is described. Conclusions: A review of bradykinin-induced angioedema and a consensus on diagnosis are presentedIntroducción: No existen guías previas españolas sobre el manejo del angioedema mediado por bradicinina. Objetivos: Revisar la fi siopatología, genética y clínica y alcanzar un consenso sobre el diagnóstico de los diferentes tipos de angioedema mediado por bradicinina a la luz de la evidencia científi ca disponible y la experiencia de los expertos, que sirva como guía para profesionales de la salud. Métodos: SGBA/GEAB, un grupo de trabajo de la SEAIC dirigió el consenso. Se realizó una revisión de los documentos científi cos publicados sobre los diferentes tipos de angioedema mediado por bradicinina [angioedema hereditario o adquirido por defi ciencia de inhibidor de la C1 esterasa, angioedema hereditario relacionado con estrógenos (AEH tipo III, AEH-FXII), angioedema inducido por IECA (inhibidores del enzima convertidor de angiotensina]. Hubo varias reuniones del SGBA/GEAB para alcanzar el consenso. Resultados: Se revisan la fi siopatología, genética y clínica de los diferentes tipos de angioedema por bradicinina. Por otro lado, se discuten los procedimientos diagnósticos y se describe el consenso alcanzado sobre el diagnóstico. Conclusiones: Se presenta una revisión del angioedema mediado por bradicinina y un consenso sobre el diagnóstico del angioedema mediado por bradicina.Dr. Teresa Caballero is a researcher with the Hospital La Paz Health Research Institute (IdiPaz) program for promoting research activities (2009). Publication of this manuscript is sponsored by the Spanish Society of Allergy and Clinical Immunology (SEAIC) and IdiPa

    Effectiveness of the combination elvitegravir/cobicistat/tenofovir/emtricitabine (EVG/COB/TFV/FTC) plus darunavir among treatment-experienced patients in clinical practice : A multicentre cohort study

    Get PDF
    Background: The aim of this study was to investigate the effectiveness and tolerability of the combination elvitegravir/cobicistat/tenofovir/emtricitabine plus darunavir (EVG/COB/TFV/FTC + DRV) in treatment-experienced patients from the cohort of the Spanish HIV/AIDS Research Network (CoRIS). Methods: Treatment-experienced patients starting treatment with EVG/COB/TFV/FTC + DRV during the years 2014-2018 and with more than 24 weeks of follow-up were included. TFV could be administered either as tenofovir disoproxil fumarate or tenofovir alafenamide. We evaluated virological response, defined as viral load (VL) < 50 copies/ml and < 200 copies/ml at 24 and 48 weeks after starting this regimen, stratified by baseline VL (< 50 or ≥ 50 copies/ml at the start of the regimen). Results: We included 39 patients (12.8% women). At baseline, 10 (25.6%) patients had VL < 50 copies/ml and 29 (74.4%) had ≥ 50 copies/ml. Among patients with baseline VL < 50 copies/ml, 85.7% and 80.0% had VL < 50 copies/ml at 24 and 48 weeks, respectively, and 100% had VL < 200 copies/ml at 24 and 48 weeks. Among patients with baseline VL ≥ 50 copies/ml, 42.3% and 40.9% had VL < 50 copies/ml and 69.2% and 68.2% had VL < 200 copies/ml at 24 and 48 weeks. During the first 48 weeks, no patients changed their treatment due to toxicity, and 4 patients (all with baseline VL ≥ 50 copies/ml) changed due to virological failure. Conclusions: EVG/COB/TFV/FTC + DRV was well tolerated and effective in treatment-experienced patients with undetectable viral load as a simplification strategy, allowing once-daily, two-pill regimen with three antiretroviral drug classes. Effectiveness was low in patients with detectable viral loads
    corecore