611 research outputs found

    Unfactored Multiblock Methods: Part I - Initial Method Development. G.U. Aero Report 9511

    Get PDF
    The use of implicit multiblock methods is discussed and an unfactored method based on a conjugate gradient type solution is described. Preconditioners appropriate to multiblock are considered along with future extensions to parallel computing

    Loneliness and Schizotypy Are Distinct Constructs, Separate from General Psychopathology

    Get PDF
    Loneliness is common in youth and associated with a significantly increased risk of psychological disorders. Although loneliness is strongly associated with psychosis, its relationship with psychosis proneness is unclear. Our aim in this paper was to test the hypothesis that loneliness and schizotypal traits, conveying risk for schizophrenia spectrum disorders, are similar but separate constructs. Pooling data from two non-clinical student samples (N = 551) we modeled the structure of the relationship between loneliness and trait schizotypy. Loneliness was assessed with the University of California, Los Angeles Loneliness Scale (UCLA-3), whilst negative (Social Anhedonia) and positive (Perceptual Aberrations) schizotypal traits were assessed with the Wisconsin Schizotypy Scales-Brief (WSS-B). Fit statistics indicated that the best fitting model of UCLA-3 scores comprises three correlated factors (Isolation, Related Connectedness, and Collective Connectedness), consistent with previous reports. Fit statistics for a two factor model of positive and negative schizotypy were excellent. Next, bi-factor analysis was used to model a general psychopatholgy factor (p) across the three loneliness factors and separate negative and positive schizotypy traits. The results showed that all items (except 1) co-loaded on p. However, with the influence of p removed, additional variance remained within separate sub-factors, indicating that loneliness and negative and positive trait schizotypy are distinct and separable constructs. Similarly, once shared variance with p was removed, correlations between sub-factors of loneliness and schizotypal traits were non-significant. These findings have important clinical implications since they suggest that loneliness should not be conflated with the expression of schizotypy. Rather, loneliness needs to be specifically targeted for assessment and treatment in youth at risk for psychosis

    Nickel hydrogen low Earth orbit test program update and status

    Get PDF
    The current status of nickel-hydrogen (NiH2) testing ongong at NWSC, Crane In, and The Aerospace Corporation, El Segundo, Ca are described. The objective of this testing is to develop a database for NiH2 battery use in Low Earth Orbit (LEO) and support applications in Medium Altitude Orbit (MAO). Individual pressure vessel-type cells are being tested. A minimum of 200 cells (3.5 in diameter and 4.5 in diameter) are included in the test, from four U.S. vendors. As of this date (Nov. 18, 1986) approximately 60 cells have completed preliminary testing (acceptance, characterization, and environmental testing) and have gone into life cycling

    It’s all about time : Precision and accuracy of Emotiv event-marking for ERPD research

    Get PDF
    Background The use of consumer-grade electroencephalography (EEG) systems for research purposes has become more prevalent. In event-related potential (ERP) research, it is critical that these systems have precise and accurate timing. The aim of the current study was to investigate the timing reliability of event-marking solutions used with Emotiv commercial EEG systems. Method We conducted three experiments. In Experiment 1 we established a jitter threshold (i.e. the point at which jitter made an event-marking method unreliable). To do this, we introduced statistical noise to the temporal position of event-marks of a pre-existing ERP dataset (recorded with a research-grade system, Neuroscan SynAmps2 at 1,000 Hz using parallel-port event-marking) and calculated the level at which the waveform peaks differed statistically from the original waveform. In Experiment 2 we established a method to identify ‘true’ events (i.e. when an event should appear in the EEG data). We did this by inserting 1,000 events into Neuroscan data using a custom-built event-marking system, the ‘Airmarker’, which marks events by triggering voltage spikes in two EEG channels. We used the lag between Airmarker events and events generated by Neuroscan as a reference for comparisons in Experiment 3. In Experiment 3 we measured the precision and accuracy of three types of Emotiv event-marking by generating 1,000 events, 1 s apart. We measured precision as the variability (standard deviation in ms) of Emotiv events and accuracy as the mean difference between Emotiv events and true events. The three triggering methods we tested were: (1) Parallel-port-generated TTL triggers; (2) Arduino-generated TTL triggers; and (3) Serial-port triggers. In Methods 1 and 2 we used an auxiliary device, Emotiv Extender, to incorporate triggers into the EEG data. We tested these event-marking methods across three configurations of Emotiv EEG systems: (1) Emotiv EPOC+ sampling at 128 Hz; (2) Emotiv EPOC+ sampling at 256 Hz; and (3) Emotiv EPOC Flex sampling at 128 Hz. Results In Experiment 1 we found that the smaller P1 and N1 peaks were attenuated at lower levels of jitter relative to the larger P2 peak (21 ms, 16 ms, and 45 ms for P1, N1, and P2, respectively). In Experiment 2, we found an average lag of 30.96 ms for Airmarker events relative to Neuroscan events. In Experiment 3, we found some lag in all configurations. However, all configurations exhibited precision of less than a single sample, with serial-port-marking the most precise when paired with EPOC+ sampling at 256 Hz. Conclusion All Emotiv event-marking methods and configurations that we tested were precise enough for ERP research as the precision of each method would provide ERP waveforms statistically equivalent to a research-standard system. Though all systems exhibited some level of inaccuracy, researchers could easily account for these during data processing

    Updating Computational Aeroelastic Models using Flight Flutter Test Data

    Get PDF

    A validation of Emotiv EPOC Flex saline for EEG and ERP research

    Get PDF
    Background Previous work has validated consumer-grade electroencephalography (EEG) systems for use in research. Systems in this class are cost-effective and easy to set up and can facilitate neuroscience outside of the laboratory. The aim of the current study was to determine if a new consumer-grade system, the Emotiv EPOC Saline Flex, was capable of capturing research-quality data. Method The Emotiv system was used simultaneously with a research-grade EEG system, Neuroscan Synamps2, to collect EEG data across 16 channels during five well-established paradigms: (1) a mismatch negativity (MMN) paradigm that involved a passive listening task in which rare deviant (1,500 Hz) tones were interspersed amongst frequent standard tones (1,000 Hz), with instructions to ignore the tones while watching a silent movie; (2) a P300 paradigm that involved an active listening task in which participants were asked to count rare deviant tones presented amongst frequent standard tones; (3) an N170 paradigm in which participants were shown images of faces and watches and asked to indicate whether the images were upright or inverted; (4) a steady-state visual evoked potential (SSVEP) paradigm in which participants passively viewed a flickering screen (15 Hz) for 2 min; and (5) a resting state paradigm in which participants sat quietly with their eyes open and then closed for 3 min each. Results The MMN components and P300 peaks were equivalent between the two systems (BF10 = 0.25 and BF10 = 0.26, respectively), with high intraclass correlations (ICCs) between the ERP waveforms (>0.81). Although the N170 peak values recorded by the two systems were different (BF10 = 35.88), ICCs demonstrated that the N170 ERP waveforms were strongly correlated over the right hemisphere (P8; 0.87–0.97), and moderately-to-strongly correlated over the left hemisphere (P7; 0.52–0.84). For the SSVEP, the signal-to-noise ratio (SNR) was larger for Neuroscan than Emotiv EPOC Flex (19.94 vs. 8.98, BF10 = 51,764), but SNR z-scores indicated a significant brain response at the stimulus frequency for both Neuroscan (z = 12.47) and Flex (z = 11.22). In the resting state task, both systems measured similar alpha power (BF10 = 0.28) and higher alpha power when the eyes were closed than open (BF10 = 32.27). Conclusions The saline version of the Emotiv EPOC Flex captures data similar to that of a research-grade EEG system. It can be used to measure reliable auditory and visual research-quality ERPs. In addition, it can index SSVEP signatures and is sensitive to changes in alpha oscillations
    • …
    corecore