136 research outputs found
Optimization methods applied to hybrid vehicle design
The use of optimization methods as an effective design tool in the design of hybrid vehicle propulsion systems is demonstrated. Optimization techniques were used to select values for three design parameters (battery weight, heat engine power rating and power split between the two on-board energy sources) such that various measures of vehicle performance (acquisition cost, life cycle cost and petroleum consumption) were optimized. The apporach produced designs which were often significant improvements over hybrid designs already reported on in the literature. The principal conclusions are as follows. First, it was found that the strategy used to split the required power between the two on-board energy sources can have a significant effect on life cycle cost and petroleum consumption. Second, the optimization program should be constructed so that performance measures and design variables can be easily changed. Third, the vehicle simulation program has a significant effect on the computer run time of the overall optimization program; run time can be significantly reduced by proper design of the types of trips the vehicle takes in a one year period. Fourth, care must be taken in designing the cost and constraint expressions which are used in the optimization so that they are relatively smooth functions of the design variables. Fifth, proper handling of constraints on battery weight and heat engine rating, variables which must be large enough to meet power demands, is particularly important for the success of an optimization study. Finally, the principal conclusion is that optimization methods provide a practical tool for carrying out the design of a hybrid vehicle propulsion system
Development of the cryogenic system of AEgIS at CERN
The AEgIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) experiment is located at the antiproton decelerator complex of CERN. The main goal of the experiment is to perform the first direct measurement of the Earthâs gravitational acceleration on antihydrogen atoms within 1% precision. The antihydrogen is produced in a cylindrical Penning trap by combining antiprotons with positrons. To reach the precision of 1%, the antihydrogen has to be cooled to 100 mK to reduce its random velocity. A dilution refrigerator is selected to deliver the necessary cooling capacity of 100 ÎŒW at 50 mK. The AEgIS cryogenic system basically consists of cryostats for a 1-T and for a 5-T superconducting magnet, a central region cryostat, a dilution refrigerator cryostat and a measurement cryostat with a MoirĂ© deflectometer to measure the gravitational acceleration. In autumn 2012, the 1-T cryostat, 5-T cryostat and central region cryostat were assembled and commissioned. The apparatus is cooled down in eight days using 2500 L of liquid helium and liquid nitrogen. During operation, the average consumption of liquid helium is 150 Lâday-1 and of liquid nitrogen 5 L·day-1. The temperature sensors at the Penning traps measured 12 K to 18 K, which is higher than expected. Simulations show that this is caused by a bad thermalization of the trap wiring. The implementation of the sub-kelvin region is foreseen for mid-2015. The antihydrogen will be cooled down to 100 mK in an ultra-cold trap consisting of multiple high-voltage electrodes made of sapphire with gold plated electrode sectors
Annihilation of low energy antiprotons in silicon
The goal of the AEIS experiment at the Antiproton
Decelerator (AD) at CERN, is to measure directly the Earth's gravitational
acceleration on antimatter. To achieve this goal, the AEIS
collaboration will produce a pulsed, cold (100 mK) antihydrogen beam with a
velocity of a few 100 m/s and measure the magnitude of the vertical deflection
of the beam from a straight path. The final position of the falling
antihydrogen will be detected by a position sensitive detector. This detector
will consist of an active silicon part, where the annihilations take place,
followed by an emulsion part. Together, they allow to achieve 1 precision on
the measurement of with about 600 reconstructed and time tagged
annihilations.
We present here, to the best of our knowledge, the first direct measurement
of antiproton annihilation in a segmented silicon sensor, the first step
towards designing a position sensitive silicon detector for the
AEIS experiment. We also present a first comparison with
Monte Carlo simulations (GEANT4) for antiproton energies below 5 MeVComment: 21 pages in total, 29 figures, 3 table
Women and citizenship post-trafficking : the case of Nepal
The research for this paper was funded by the Economic and Social Research Council â ESRC Res-062-23-1490: âPost Trafficking in Nepal: Sexuality and Citizenship in Livelihood Strategiesâ. Diane Richardson would like to acknowledge the support provided by the award of a Leverhulme TrustMajor Research Fellowship, âTransforming Citizenship: Sexuality, Gender and Citizenship Strugglesâ [award MRF-2012-106].This article analyses the relationship between gender, sexuality and citizenship embedded in models of citizenship in the Global South, specifically in South Asia, and the meanings associated with having - or not having - citizenship. It does this through an examination of women's access to citizenship in Nepal in the context of the construction of the emergent nation state in the 'new' Nepal 'post-conflict'. Our analysis explores gendered and sexualized constructions of citizenship in this context through a specific focus on women who have experienced trafficking, and are beginning to organize around rights to sustainable livelihoods and actively lobby for changes in citizenship rules which discriminate against women. Building from this, in the final section we consider important implications of this analysis of post-trafficking experiences for debates about gender, sexuality and citizenship more broadly.Publisher PDFPeer reviewe
Developments in silicone technology for use in stoma care
YesSoft silicone's flexibility, adhesive capacity and non-toxic, non-odourous and hypoallergenic nature have made it an established material for adhesive and protective therapeutic devices. In wound care, silicone is a component of contact layer dressings for superficial wounds and silicone gel sheeting for reducing the risk of scarring, as well as of barriers for incontinence-associated dermatitis. Regarding stoma accessories, silicone is established in barrier films to prevent contact dermatitis, adhesive removers to prevent skin stripping and filler gels to prevent appliance leaks. Until recently, silicone has not been used in stoma appliances flanges, as its hydrophobic nature has not allowed for moisture management to permit trans-epidermal water loss and prevent maceration. Traditional hydrocolloid appliances manage moisture by absorbing water, but this can lead to saturation and moisture-associated skin damage (MASD), as well as increased adhesion and resultant skin tears on removal, known as medical adhesive-related skin injury (MARSI). However, novel silicone compounds have been developed with a distinct evaporation-based mechanism of moisture management. This uses colloidal separation to allow the passage of water vapour at a rate equivalent to normal trans-epidermal water loss. It has been shown to minimise MASD, increase wear time and permit atraumatic removal without the use of adhesive solvents. Trio Healthcare has introduced this technology with a range of silicone-based flange extenders and is working with the University of Bradford Centre for Skin Sciences on prototype silicone-based stoma appliance flanges designed to significantly reduce the incidence of peristomal skin complications, such as MARSI and MASD. It is hoped that this will also increase appliance wear time, reduce costs and improve patient quality of life
Measuring 129Xe transfer across the bloodâbrain barrier using MR spectroscopy
Purpose
This study develops a tracer kinetic model of xenon uptake in the human brain to determine the transfer rate of inhaled hyperpolarized 129Xe from cerebral blood to gray matter that accounts for the effects of cerebral physiology, perfusion and magnetization dynamics. The 129Xe transfer rate is expressed using a tracer transfer coefficient, which estimates the quantity of hyperpolarized 129Xe dissolved in cerebral blood under exchange with depolarized 129Xe dissolved in gray matter under equilibrium of concentration.
Theory and Methods
Timeâresolved MR spectra of hyperpolarized 129Xe dissolved in the human brain were acquired from three healthy volunteers. Acquired spectra were numerically fitted with five Lorentzian peaks in accordance with known 129Xe brain spectral peaks. The signal dynamics of spectral peaks for gray matter and red blood cells were quantified, and correction for the 129Xe T1 dependence upon blood oxygenation was applied. 129Xe transfer dynamics determined from the ratio of the peaks for gray matter and red blood cells was numerically fitted with the developed tracer kinetic model.
Results
For all the acquired NMR spectra, the developed tracer kinetic model fitted the data with tracer transfer coefficients between 0.1 and 0.14.
Conclusion
In this study, a tracer kinetic model was developed and validated that estimates the transfer rate of HP 129Xe from cerebral blood to gray matter in the human brain
On-line motion planning for medical applications
Enhancing the quality of surgical interventions is one of the main goals of surgical robotics. Thus we have devised a surgical robotic system for maxillofacial surgery which can be used as an intelligent intraoperative surgical tool. Up to now a surgeon preoperatively plans an intervention by studying twodimensional X-rays, thus neglecting the third dimension. In course of the special research programme "Computer and Sensor Aided Surgery" a planning system has been developed at our institute, which allows the surgeon to plan an operation on a threedimensional computer model of the patient . Transposing the preoperatively planned bone cuts, bore holes, cavities, and milled surfaces during surgery still proves to be a problem, as no adequate means are at hand: the actual performance of the surgical intervention and the surgical outcome solely depend on the experience and the skill of the operating surgeon. In this paper we present our approach of a surgical robotic system to be used in maxillofacial surgery. Special stress is being laid upon the modelling of the environment in the operating theatre and the motion planning of our surgical robot
On-line motion planning for medical applications
Enhancing the quality of surgical interventions is one of the main goals of surgical robotics. Thus we have devised a surgical robotic system for maxillofacial surgery which can be used as an intelligent intraoperative surgical tool. Up to now a surgeon preoperatively plans an intervention by studying twodimensional X-rays, thus neglecting the third dimension. In course of the special research programme "Computer and Sensor Aided Surgery" a planning system has been developed at our institute, which allows the surgeon to plan an operation on a threedimensional computer model of the patient . Transposing the preoperatively planned bone cuts, bore holes, cavities, and milled surfaces during surgery still proves to be a problem, as no adequate means are at hand: the actual performance of the surgical intervention and the surgical outcome solely depend on the experience and the skill of the operating surgeon. In this paper we present our approach of a surgical robotic system to be used in maxillofacial surgery. Special stress is being laid upon the modelling of the environment in the operating theatre and the motion planning of our surgical robot
- âŠ