793 research outputs found

    Environmental Impact of Surgical Masks Consumption in Italy Due to COVID-19 Pandemic

    Get PDF
    The COVID-19 pandemic suddenly changed the lifestyle of billions of people. Face masks became indispensable to protect from the contagion providing a significant environmental impact. The aim of this work is to propose possible solutions to decrease masks’ impact on the environment. For this reason, different masks (surgical and fabric) were considered, and the CO2 emissions associated with the mask materials production were calculated. Carbon Footprint (CF) for each material composing the masks was evaluated through the database Ces Selector 2019. The software Qgis (version 2.18.20) allows us to elaborate the CO2 emissions maps for each Italian region. Finally, for surgical masks, which are often imported from abroad, the CF related to transport was considered. It results that fabric masks are a sustainable solution to prevent contagion. The total CO2 emission associated with the use of fabric masks from the beginning of the pandemic (March 2020) to December 2021 resulted in about 7 kton compared to 350 kton for surgical masks

    Phosphorus recovery from a pilot-scale grate furnace: influencing factors beyond wet chemical leaching conditions

    Get PDF
    Phosphorus is a non-renewable resource going to exhaustion in the future. Sewage sludge ash is a promising secondary raw material due to its high phosphorus content. In this work, the distribution of 19 elements in bottom and cyclone ashes from pilot-scale grate furnace have been monitored to determine the suitability for the phosphorus acid extraction. Moreover, the influence of some parameters beyond wet chemical leaching conditions were investigated. Experimental results showed that bottom ash presented lower contamination in comparison to cyclone ash and low co-dissolution of heavy metals (especially Cr, Pb and Ni), while high phosphorus extraction efficiencies (76-86%) were achieved. High Al content in the bottom ash (9.4%) negatively affected the phosphorus extraction efficiency as well as loss on ignition, while the particle size reduction was necessary for ensuring a suitable contact surface. The typology of precipitating agents did not strongly affect the phosphorus precipitation, while pH was the key parameter. At pH 3.5-5, phosphorus precipitation efficiencies higher than 90% were achieved, with a mean phosphorus content in the recovered material equal to 16-17%, comparable to commercial fertilizers. Instead, the co-precipitation of Fe and Al had a detrimental effect on the recovered material, indicating the need for additional treatments

    waste silica sources as heavy metal stabilizers for municipal solid waste incineration fly ash

    Get PDF
    Abstract The present work discusses a new method, based on the use of silica fume, for heavy metal stabilization. The inertization procedure is reported and compared with other technologies, involving the employ of amorphous silica as stabilizing agent for municipal solid waste incinerator fly ash treatment (i.e. colloidal silica and rice husk ash). The obtained final materials are characterized in terms of chemical composition and phase analysis. The reported method, realized at room temperature, employs all waste or by-product materials. As a consequence it appears to be economically and environmentally sustainable

    Knee position at the moment of bone bruise could reflect the late phase of non-contact anterior cruciate ligament injury rather than the mechanisms leading to ligament failure

    Get PDF
    Purpose: The aim of the present study was to trace knee position at the time of bone bruise (BB) and investigate how much this position departed from the knee biomechanics of an in vivo flexion–extension. Methods: From an original cohort of 62 patients, seven (11%) presented bicompartmental edemas and were included in the study. 3D models of bones and BB were obtained from MRI. Matching bone edemas, a reconstruction of the knee at the moment of BB was obtained. For the same patients, knee kinematics of a squat was calculated using dynamic Roentgen sterephotogrammetric analysis (RSA). Data describing knee position at the moment of BB were compared to kinematics of the same knee extrapolated from RSA system. Results: Knee positions at the moment of BB was significantly different from the kinematics of the squat. In particular, all the patients’ positions were out of squat range for both anterior and proximal tibial translation, varus–valgus rotation (five in valgus and two in varus), tibial internal–external rotation (all but one, five externally and one internally). A direct comparison at same flexion angle between knee at the moment of BB (average 46.1° ± 3.8°) and knee during squat confirmed that tibia in the former was significantly more anterior (p < 0.0001), more externally rotated (6.1 ± 3.7°, p = 0.04), and valgus (4.1 ± 2.4°, p = 0.03). Conclusion: Knee position at the moment of Bone bruise position was out of physiological in-vivo knee range of motion and could reflect a locked anterior subluxation occurring in the late phase of ACL injury rather than the mechanism leading to ligament failure. Level of evidence: Level I

    Thermo-mechanical behavior of surface acoustic waves in ordered arrays of nanodisks studied by near infrared pump-probe diffraction experiments

    Full text link
    The ultrafast thermal and mechanical dynamics of a two-dimensional lattice of metallic nano-disks has been studied by near infrared pump-probe diffraction measurements, over a temporal range spanning from 100 fs to several nanoseconds. The experiments demonstrate that, in these systems, a two-dimensional surface acoustic wave (2DSAW), with a wavevector given by the reciprocal periodicity of the array, can be excited by ~120 fs Ti:sapphire laser pulses. In order to clarify the interaction between the nanodisks and the substrate, numerical calculations of the elastic eigenmodes and simulations of the thermodynamics of the system are developed through finite-element analysis. At this light, we unambiguously show that the observed 2DSAW velocity shift originates from the mechanical interaction between the 2DSAWs and the nano-disks, while the correlated 2DSAW damping is due to the energy radiation into the substrate.Comment: 13 pages, 10 figure

    The motor cortex of the sheep: laminar organization, projections and diffusion tensor imaging of the intracranial pyramidal and extrapyramidal tracts

    Get PDF
    The laminar organization of the motor cortex of the sheep and other large domestic herbivores received scarce attention and is generally considered homologous to that of rodents and primates. Thickness of the cortex, subdivision into layers and organization are scarcely known. In the present study, we applied different modern morphological, mathematical and image-analyses techniques to the study of the motor area that controls movements of the forelimb in the sheep. The thickness of the cortex resulted comparable to that of other terrestrial Cetartiodactyls (but thicker than in marine Cetartiodactyls of similar body mass). The laminar organization showed marked development of layer 1, virtual absence of layer 4, and image analysis suggested prevalence of large irregular neural cells in the deeper layers. Diffusion tensor imaging revealed robust projections from the motor cortex to the pyramids in the brainstem, and well evident tracts descending to the tegmentum of the mesencephalon and dorsal pons. Our data contrast the general representation of the motor system of this species, considered to be predominantly based on extra-pyramidal tracts that originate from central pattern generators in the brainstem. © 2019, Springer-Verlag GmbH Germany, part of Springer Nature

    Prospective assessment of integrating the existing emergency medical system with automated external defibrillators fully operated by volunteers and laypersons for out-of-hospital cardiac arrest: the Brescia Early Defibrillation Study (BEDS)

    Get PDF
    AIMS: There are few data on the outcomes of cardiac arrest (CA) victims when the defibrillation capability of broad rural and urban territories is fully operated by volunteers and laypersons. METHODS AND RESULTS: In this study, we investigated whether a programme based on diffuse deployment of automated external defibrillators (AEDs) operated by 2186 trained volunteers and laypersons across the County of Brescia, Italy (area: 4826 km(2); population: 1 112 628), would safely and effectively impact the current survival among victims of out-of-hospital CA. Forty-nine AEDs were added to the former emergency medical system that uses manual EDs in the emergency department of 10 county hospitals and in five medically equipped ambulances. The primary endpoint was survival free of neurological impairment at 1-year follow-up. Data were analysed in 692 victims before and in 702 victims after the deployment of the AEDs. Survival increased from 0.9% (95% CI 0.4-1.8%) in the historical cohort to 3.0% (95% CI 1.7-4.3%) (P=0.0015), despite similar intervals from dispatch to arrival at the site of collapse [median (quartile range): 7 (4) min vs. 6 (6) min]. Increase of survival was noted both in the urban [from 1.4% (95% CI 0.4-3.4 %) to 4.0% (95% CI 2.0-6.9 %), P=0.024] and in the rural territory [from 0.5% (95% CI 0.1-1.6%) to 2.5% (95% CI 1.3-4.2%), P=0.013]. The additional costs per quality-adjusted life year saved amounted to euro39 388 (95% CI euro16 731-49 329) during the start-up phase of the study and to euro23 661 (95% CI euro10 327-35 528) at steady state. CONCLUSION: Diffuse implementation of AEDs fully operated by trained volunteers and laypersons within a broad and unselected environment proved safe and was associated with a significantly higher long-term survival of CA victims

    A computer simulation protocol to assess the accuracy of a Radio Stereometric Analysis (RSA) image processor according to the ISO-5725

    Full text link
    Radio-Stereometric-Analysis and x-ray fluoroscopy are radiological techniques that require dedicated software to process data. The accurate calibration of these software is therefore critical. The aim of this work is to produce a protocol for evaluating the softwares' accuracy according to the ISO-5725. A series of computer simulations of the radiological setup and images were employed. The noise level of the images was also changed to evaluate the accuracy with different image qualities. The protocol was tested on a custom software developed by the authors. Radiological scene reconstruction accuracy was of (0.092 +- 0.14) mm for tube position, and (0.38 +- 0.31) mm / (2.09 +- 1.39) deg for detectors oriented in a direction other than the source-detector direction. In the source-detector direction the accuracy was of (2.68 +- 3.08) mm for tube position, and of (0.16 +- 0.27) mm / (0.075 +- 1.16) deg for the detectors. These disparate results are widely discussed in the literature. Model positioning and orientation was also highly accurate: (0.22 +- 0.46) mm / (0.26 +- 0.22) deg. Accuracy was not affected by the noise level. The protocol was able to assess the accuracy of the RSA system. It was also useful to detect and fix hidden bugs. It was also useful to detect and resolve hidden bugs in the software, and in optimizing the algorithms

    Ultracompact microinterferometer-based fiber Bragg grating interrogator on a silicon chip

    Get PDF
    We report an interferometer-based multiplexed fiber Bragg grating (FBG) interrogator using silicon photonic technology. The photonic-integrated system includes the grating coupler, active and passive interferometers, interferometers, a 12-channel wavelength-division-multiplexing (WDM) filter, and Ge photodiodes, all integrated on a 6x8 mm2 silicon chip. The system also includes optical and electric interfaces to a printed board, which is connected to a real-time electronic board that actively performs the phase demodulation processing using a multitone mixing (MTM) technique. The device with active demodulation, which uses thermally-based phase shifters, features a noise figure of σ  =  0.13 pm at a bandwidth of 700 Hz, which corresponds to a dynamic spectral resolution of 4.9 fm/Hz1/2. On the other hand, the passive version of the system, based on a 90Âș-hybrid coupler, features a noise figure of σ  =  2.55 pm at a bandwidth of 10 kHz, also showing successful detection of a 42 kHz signal when setting the bandwidth to 50 kHz. These results demonstrate the advantage of integrated photonics, which allows the integration of several systems with different demodulation schemes in the same chip and guarantees easy scalability to a higher number of ports without increasing the dimensions or the cost
    • 

    corecore