30 research outputs found
Coherent π0 photoproduction on the deuteron up to 4 GeV
The differential cross section for 2H(γ,d)π0 has been measured at deuteron center-of-mass angles of 90° and 136°. This work reports the first data for this reaction above a photon energy of 1 GeV, and permits a test of the apparent constituent counting rule and reduced nuclear amplitude behavior as observed in elastic ed scattering. Measurements were performed up to a photon energy of 4.0 GeV, and are in good agreement with previous lower energy measurements. Overall, the data are inconsistent with both constituent-counting rule and reduced nuclear amplitude predictions
Test beam performance measurements for the Phase I upgrade of the CMS pixel detector
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is (99.95 ± 0.05) %, while the intrinsic spatial resolutions are (4.80 ± 0.25) μm and (7.99 ± 0.21) μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.Peer reviewe
Measurements of Deuteron Photodisintegration up to 4.0 GeV
The first measurements of the differential cross section for the d(γ,p)n reaction up to 4.0 GeV were performed at the Continuous Electron Beam Accelerator Facility (CEBAF) at Thomas Jefferson Laboratory. We report the cross sections at the proton center-of-mass angles of 36°, 52°, 69°, and 89°. These results are in reasonable agreement with previous measurements at lower energy. The 89° and 69° data show constituent-counting-rule behavior up to 4.0 GeV photon energy. The 52° and 36° data disagree with the counting-rule behavior. The quantum chromodynamics (QCD) model of nuclear reactions involving reduced amplitudes disagrees with the present data.U.S. Department of Energy, National Science Foundatio
P-Type Silicon Strip Sensors for the new CMS Tracker at HL-L-HC
Abstract: The upgrade of the LHC to the High-Luminosity LHC (HL-LHC) is expected to increase
the LHC design luminosity by an order of magnitude. This will require silicon tracking detectors
with a significantly higher radiation hardness. The CMS Tracker Collaboration has conducted an
irradiation and measurement campaign to identify suitable silicon sensor materials and strip designs
for the future outer tracker at the CMS experiment. Based on these results, the collaboration has
chosen to use n-in-p type silicon sensors and focus further investigations on the optimization of that
sensor type
Hive Collective Intelligence for Cloud Robotics: A Hybrid Distributed Robotic Controller Design for Learning and Adaptation
Activity Patterns and Egg-Production in Coccophagus-Bartletti, An Aphelinid Parasitoid of Scale Insects
Evaluación de hemerotecas de prensa digital: indicadores y ejemplos de buenas prácticas
La gran mayoría de los diarios digitales facilitan el acceso a la información retrospectiva mediante servicios de hemerotecas o archivos de prensa, un producto de notable interés para bibliotecas y otros servicios de información. El objetivo de este estudio es determinar cuáles son los indicadores fundamentales para la evaluación de hemerotecas digitales y, además, señalar ejemplos de buenas prácticas en España para cada uno de ellos. Se propone una relación de veintisiete indicadores agrupados en cuatro grandes apartados (aspectos generales, contenidos, sistema de consulta, y presentación de resultados), se describe cada uno de ellos y se incluye algún ejemplo de buena aplicación. Metodológicamente, se ha partido de la revisión de la bibliografía especializada en evaluación de recursos web, bases de datos y hemerotecas digitales, así como del análisis de hemerotecas de diarios de España y Catalunya. La utilización de estos indicadores puede ser de utilidad para que bibliotecas y otros servicios de información puedan orientar a sus usuarios en la consulta retrospectiva de información de prensa