2,801 research outputs found

    High-precision gravimetric survey in support of lunar laser ranging at Haleakala, Maui, 1976 - 1978

    Get PDF
    The planning, observations and adjustment of high-precision gravity survey networks established on the islands of Maui and Oahu as part of the geodetic-geophysical program in support of lunar laser ranging at Haleakala, Maui, Hawaii are described. The gravity survey networks include 43 independently measured gravity differences along the gravity calibration line from Kahului Airport to the summit of Mt. Haleakala, together with some key points close to tidal gauges on Maui, and 40 gravity differences within metropolitan Honolulu. The results of the 1976-1978 survey are compared with surveys made in 1961 and in 1964-1965. All final gravity values are given in the system of the international gravity standardization net 1971 (IGSN 71); values are obtained by subtracting 14.57 mgal from the Potsdam value at the gravity base station at the Hickam Air Force Base, Honolulu

    All the boys love Mary

    Get PDF
    https://digitalcommons.ithaca.edu/sheetmusic/1210/thumbnail.jp

    All The Boys Love Mary

    Get PDF
    https://digitalcommons.library.umaine.edu/mmb-vp/1046/thumbnail.jp

    Penetration depth, multiband superconductivity, and absence of muon-induced perturbation in superconducting PrOs4_{4}Sb12_{12}

    Full text link
    Transverse-field muon spin rotation (μ\muSR) experiments in the heavy-fermion superconductor PrOs4_{4}Sb12_{12} (Tc=1.85T_{c}=1.85 K) suggest that the superconducting penetration depth λ(T)\lambda(T) is temperature-independent at low temperatures, consistent with a gapped quasiparticle excitation spectrum. In contrast, radiofrequency (rf) inductive measurements yield a stronger temperature dependence of λ(T)\lambda(T), indicative of point nodes in the gap. This discrepancy appears to be related to the multiband structure of PrOs4_{4}Sb12_{12}. Muon Knight shift measurements in PrOs4_{4}Sb12_{12} suggest that the perturbing effect of the muon charge on the neighboring Pr3+^{3+} crystalline electric field is negligibly small, and therefore is unlikely to cause the difference between the μ\muSR and rf results.Comment: 10 pages, 7 figure

    Delocalization of slowly damped eigenmodes on Anosov manifolds

    Full text link
    We look at the properties of high frequency eigenmodes for the damped wave equation on a compact manifold with an Anosov geodesic flow. We study eigenmodes with spectral parameters which are asymptotically close enough to the real axis. We prove that such modes cannot be completely localized on subsets satisfying a condition of negative topological pressure. As an application, one can deduce the existence of a "strip" of logarithmic size without eigenvalues below the real axis under this dynamical assumption on the set of undamped trajectories.Comment: 28 pages; compared with version 1, minor modifications, add two reference

    Regina Lectures on Fat Points

    Full text link
    These notes are a record of lectures given in the Workshop on Connections Between Algebra and Geometry at the University of Regina, May 29--June 1, 2012. The lectures were meant as an introduction to current research problems related to fat points for an audience that was not expected to have much background in commutative algebra or algebraic geometry (although sections 8 and 9 of these notes demand somewhat more background than earlier sections).Comment: 32 pages, 3 figure

    Spin dynamics in copper metaborate CuB2O4CuB_2 O_4 studied by muon spin relaxation

    Full text link
    Copper metaborate CuB2_2O4_{4} was studied by muon spin relaxation measurements in order to clarify its static and dynamic magnetic properties. The time spectra of muon spin depolarization suggest that the local fields at the muon site contain both static and fluctuating components in all ordered phases down to 0.3 K. In the weak ferromagnetic phase (20 K~>T>>T>~9.3 K), the static component is dominant. On the other hand, upon cooling the fluctuating component becomes dominant in the incommensurate helix phase (9.3K > T > 1.4K). The dynamical fluctuations of the local fields persist down to 0.3K, where a new incommensurate phase (T < 1.4K) is expected to appear. This result suggests that spins fluctuate even at T \to 0. We propose two possible origins of the remnant dynamical spin fluctuations: frustration of the exchange interactions and the dynamic behavior of the soliton lattice

    Bowel Preparation for Colonoscopy with Sodium Phosphate Solution versus Polyethylene Glycol-Based Lavage: A Multicenter Trial

    Get PDF
    Background: Adequate bowel preparation is essential for accurate colonoscopy. Both oral sodium phosphate (NaP) and polyethylene glycol-based lavage (PEG-ELS) are used predominantly as bowel cleansing modalities. NaP has gained popularity due to low drinking volume and lower costs. The purpose of this randomized multicenter observer blinded study was to compare three groups of cleansing (NaP, NaP + sennosides, PEG-ELS + sennosides) in reference to tolerability, acceptance, and cleanliness. Patient and Methods: 355 outpatients between 18 and 75 years were randomized into three groups (A, B, C) receiving NaP = A, NaP, and sennosides = B or PEG-ELS and sennosides = C. Gastroenterologists performing colonoscopies were blinded to the type of preparation. All patients documented tolerance and adverse events. Vital signs, premedication, completeness, discomfort, and complications were recorded. A quality score (0–4) of cleanliness was generated. Results: The three groups were similar with regard to age, sex, BMI, indication for colonoscopy, and comorbidity. Drinking volumes (L) (A = 4.33 + 1.2, B = 4.56 + 1.18, C = 4.93 + 1.71) were in favor of NaP (P = .005). Discomfort from ingested fluid was recorded in A = 39.8% (versus C: P = .015), B = 46.6% (versus C: P = .147), and C = 54.6%. Differences in tolerability and acceptance between the three groups were statistically not significant. No differences in adverse events and the cleanliness effects occurred in the three groups (P = .113). The cleanliness quality scores 0–2 were calculated in A: 77.7%, B: 86.7%, and C: 85.2%. Conclusions: These data fail to demonstrate significant differences in tolerability, acceptance, and preparation quality between the three types of bowel preparation for colonoscopy. Cleansing with NaP was not superior to PEG-ELS
    corecore