164 research outputs found
Illicit and Counterfeit Drug Analysis by Morphologically Directed Raman Spectroscopy
Morphologically directed Raman spectroscopy (MDRS) is a novel tool for the forensic analysis of illicit and counterfeit drug samples. MDRS combines Raman microspectroscopy with automated particle imaging so that physical and chemical information about the components of a mixture sample can be obtained. Results of automated particle imaging are used to determine samples for Raman analysis. The use of MDRS for these types of samples can be employed for both forensic investigations and adjudications of cases. The method provides insight about the physical and chemical composition of the sample, as well as about manufacturing and sample history. Here, MDRS was used in four different illicit and counterfeit drug analyses: (1) examination of a multicomponent drug mixture where the results could be used for comparative source attribution, (2) the detection of low (or trace) concentration particles in a drug sample, (3) the analysis of synthetic cathinone samples (i.e., bath salts), and (4) a study of counterfeit pharmaceutical products
Al0.52In0.48P 55Fe x-ray-photovoltaic battery
An Al0.52In0.48P 55Fe radioisotope microbattery is demonstrated over the temperature range −20 °C to 160 °C. Al0.52In0.48P p+-i-n+ mesa structures were used to collect the photons from a 238 MBq 55Fe radioisotope x-ray source. The effects of temperature on the key microbattery parameters were studied. Increasing the temperature, the saturation current increased; whilst the open circuit voltage, the maximum power and the conversion efficiency decreased. An open circuit voltage of 0.97V and a conversion efficiency of 22% were measured in a single p+-i-n+ mesa structure at −20 °C. The highest total microbattery maximum output power using two mesa structures was 1.2 pW at −20 °C
Augmenting forearm crutches with wireless sensors for lower limb rehabilitation
Forearm crutches are frequently used in the rehabilitation of an injury to the lower limb. The recovery rate is improved if the patient correctly applies a certain fraction of their body weight (specified by a clinician) through the axis of the crutch, referred to as partial weight bearing (PWB). Incorrect weight bearing has been shown to result in an extended recovery period or even cause further damage to the limb. There is currently no minimally invasive tool for long-term monitoring of a patient's PWB in a home environment. This paper describes the research and development of an instrumented forearm crutch that has been developed to wirelessly and autonomously monitor a patient's weight bearing over the full period of their recovery, including its potential use in a home environment. A pair of standard forearm crutches are augmented with low-cost off-the-shelf wireless sensor nodes and electronic components to provide indicative measurements of the applied weight, crutch tilt and hand position on the grip. Data are wirelessly transmitted between crutches and to a remote computer (where they are processed and visualized in LabVIEW), and the patient receives biofeedback by means of an audible signal when they put too much or too little weight through the crutch. The initial results obtained highlight the capability of the instrumented crutch to support physiotherapists and patients in monitoring usage
Investigation of a temperature tolerant InGaP (GaInP) converter layer for a 63Ni betavoltaic cell
A prototype InGaP p+–i–n+ mesa photodiode was studied for its potential as the energy conversion device in a 63Ni betavoltaic cell; its electrical performance was analysed across the temperature range −20 °C to 100 °C. The results show that the InGaP detector when illuminated with a laboratory 63Ni radioisotope beta particle source had a maximum output power of 0.92 pW at −20 °C, this value decreased at higher temperatures. A decrease in the open circuit voltage and in the cell internal conversion ef ciency were also observed when the temperature was increased: at −20 °C, the open circuit voltage and the cell internal conversion ef ciency had values of 0.69 V and 4%, respectively. A short circuit current of 4.5 pA was measured at −20 °C
Boundary-Layer-Ingesting Inlet Flow Control
This paper gives an overview of a research study conducted in support of the small-scale demonstration of an active flow control system for a boundary-layer-ingesting (BLI) inlet. The effectiveness of active flow control in reducing engine inlet circumferential distortion was assessed using a 2.5% scale model of a 35% boundary-layer-ingesting flush-mounted, offset, diffusing inlet. This experiment was conducted in the NASA Langley 0.3-meter Transonic Cryogenic Tunnel at flight Mach numbers with a model inlet specifically designed for this type of testing. High mass flow actuators controlled the flow through distributed control jets providing the active flow control. A vortex generator point design configuration was also tested for comparison purposes and to provide a means to examine a hybrid vortex generator and control jets configuration. Measurements were made of the onset boundary layer, the duct surface static pressures, and the mass flow through the duct and the actuators. The distortion and pressure recovery were determined by 40 total pressure measurements on 8 rake arms each separated by 45 degrees and were located at the aerodynamic interface plane. The test matrix was limited to a maximum free-stream Mach number of 0.85 with scaled mass flows through the inlet for that condition. The data show that the flow control jets alone can reduce circumferential distortion (DPCPavg) from 0.055 to about 0.015 using about 2.5% of inlet mass flow. The vortex generators also reduced the circumferential distortion from 0.055 to 0.010 near the inlet mass flow design point. Lower inlet mass flow settings with the vortex generator configuration produced higher distortion levels that were reduced to acceptable levels using a hybrid vortex generator/control jets configuration that required less than 1% of the inlet mass flow
Automatic Detection of User Abilities through the SmartAbility Framework
This paper presents a proposed smartphone application for the unique SmartAbility Framework that
supports interaction with technology for people with reduced physical ability, through focusing on
the actions that they can perform independently. The Framework is a culmination of knowledge
obtained through previously conducted technology feasibility trials and controlled usability
evaluations involving the user community. The Framework is an example of ability-based design that
focuses on the abilities of users instead of their disabilities. The paper includes a summary of
Versions 1 and 2 of the Framework, including the results of a two-phased validation approach,
conducted at the UK Mobility Roadshow and via a focus group of domain experts. A holistic model
developed by adapting the House of Quality (HoQ) matrix of the Quality Function Deployment (QFD)
approach is also described. A systematic literature review of sensor technologies built into smart
devices establishes the capabilities of sensors in the Android and iOS operating systems. The review
defines a set of inclusion and exclusion criteria, as well as search terms used to elicit literature from
online repositories. The key contribution is the mapping of ability-based sensor technologies onto
the Framework, to enable the future implementation of a smartphone application. Through the
exploitation of the SmartAbility application, the Framework will increase technology amongst people
with reduced physical ability and provide a promotional tool for assistive technology manufacturers
Recommended from our members
Performance of the FONT3 Fast Analogue Intra-Train Beam-Based Feedback System at ATF
We report results of beam tests of the FONT3 intra-train position feedback system prototype at the Accelerator Test Facility (ATF) at KEK. The feedback system incorporates a novel beam position monitor (BPM) processor with latency below 5 nanoseconds, and a kicker driver amplifier with similar low latency. The 56 nanosecond-long bunchtrain in the ATF extraction line was used to test the prototype feedback system. The achieved latency of 23ns provides a demonstration of intra-train feedback on very short timescales relevant even for the CLIC Linear Collider design
Recommended from our members
Design of the ILC Prototype FONT4 Digital Intra-Train Beam-Based Feedback System
We present the design of the FONT4 digital intra-train beam position feedback system prototype and preliminary results of initial beam tests at the Accelerator Test Facility (ATF) at KEK. The feedback system incorporates a fast analogue beam position monitor (BPM) front-end signal processor, a digital feedback board, and a kicker driver amplifier. The short bunchtrain, comprising 3 electron bunches separated by c. 150ns, in the ATF extraction line was used to test components of the prototype feedback system
- …