1,423 research outputs found

    A window opening algorithm and UK office temperature field results and thermal simulation

    Get PDF
    This investigation of the window opening data from extensive field surveys in UK office buildings investigates 1) how people control the indoor environment by opening windows, 2) the cooling potential of opening windows, and 3) the use of an “adaptive algorithm” for predicting window opening behaviour for thermal simulation in ESP-r. We found that the mean indoor and outdoor temperatures when the window was open were higher than when it was closed, but show that nonetheless there was a useful cooling effect from opening a window. The adaptive algorithm for window opening behaviour was then used in thermal simulation studies for some typical office designs. The thermal simulation results were in general agreement with the findings of the field surveys

    The thermal simulation of an office building implementing a new behavioural algorithm for window opening and the use of ceiling fans

    Get PDF
    This investigation of the window opening data from extensive field surveys in UK office buildings investigates 1) how people control the indoor environment by opening windows, 2) the cooling potential of opening windows, and 3) the use of an “adaptive algorithm” for predicting window opening behaviour for thermal simulation in ESP-r. We found that the mean indoor and outdoor temperatures when the window was open were higher than when it was closed, but show that nonetheless there was a useful cooling effect from opening a window. The adaptive algorithm for window opening behaviour was then used in thermal simulation studies for some typical office designs. The thermal simulation results were in general agreement with the findings of the field surveys

    Minimization of Radiation Exposure due to Computed Tomography in Inflammatory Bowel Disease

    Get PDF
    Patient awareness and concern regarding the potential health risks from ionizing radiation have peaked recently (Coakley et al., 2011) following widespread press and media coverage of the projected cancer risks from the increasing use of computed tomography (CT) (Berrington et al., 2007). The typical young and educated patient with inflammatory bowel disease (IBD) may in particular be conscious of his/her exposure to ionising radiation as a result of diagnostic imaging. Cumulative effective doses (CEDs) in patients with IBD have been reported as being high and are rising, primarily due to the more widespread and repeated use of CT (Desmond et al., 2008). Radiologists, technologists, and referring physicians have a responsibility to firstly counsel their patients accurately regarding the actual risks of ionizing radiation exposure; secondly to limit the use of those imaging modalities which involve ionising radiation to clinical situations where they are likely to change management; thirdly to ensure that a diagnostic quality imaging examination is acquired with lowest possible radiation exposure. In this paper, we synopsize available evidence related to radiation exposure and risk and we report advances in low-dose CT technology and examine the role for alternative imaging modalities such as ultrasonography or magnetic resonance imaging which avoid radiation exposure

    Considering the impact of situation-specific motivations and constraints in the design of naturally ventilated and hybrid buildings

    Get PDF
    A simple logical model of the interaction between a building and its occupants is presented based on the principle that if free to do so, people will adjust their posture, clothing or available building controls (windows, blinds, doors, fans, and thermostats) with the aim of achieving or restoring comfort and reducing discomfort. These adjustments are related to building design in two ways: first the freedom to adjust depends on the availability and ease-of-use of control options; second the use of controls affects building comfort and energy performance. Hence it is essential that these interactions are considered in the design process. The model captures occupant use of controls in response to thermal stimuli (too warm, too cold etc.) and non-thermal stimuli (e.g. desire for fresh air). The situation-specific motivations and constraints on control use are represented through trigger temperatures at which control actions occur, motivations are included as negative constraints and incorporated into a single constraint value describing the specifics of each situation. The values of constraints are quantified for a range of existing buildings in Europe and Pakistan. The integration of the model within a design flow is proposed and the impact of different levels of constraints demonstrated. It is proposed that to minimise energy use and maximise comfort in naturally ventilated and hybrid buildings the designer should take the following steps: 1. Provide unconstrained low energy adaptive control options where possible, 2. Avoid problems with indoor air quality which provide motivations for excessive ventilation rates, 3. Incorporate situation-specific adaptive behaviour of occupants in design simulations, 4. Analyse the robustness of designs against variations in patterns of use and climate, and 5. Incorporate appropriate comfort standards into the operational building controls (e.g. BEMS)

    Platinum bisphosphine complexes of 1,8-naphthosultone

    Get PDF
    Funding: Engineering and Physical Sciences Research Council (EPSRC)A series of three platinum (II) bisphosphine complexes 1-3 [Pt(1-(SO2),8-(O)-nap)(PR3)2] (where R3 = Ph3, Ph2Me, Me2Ph) have been prepared by metathesis from cis-[Pt(PR3)2Cl2)] and the dilithium salt of 1,8-naphthosultone. The novel compounds were fully characterised by X-ray crystallography, multinuclear NMR, IR and MS. The molecular structures of 1-3 were compared by measuring the peri-distance, splay angle magnitude, peri-atom displacement, naphthalene ring torsions, aromatic ring orientations and the geometry around the platinum centre. The platinum metal adopts a distorted square planar geometry in all three complexes which causes deformation of the naphthalene system. The degree of molecular deformation does not decrease upon going from 1 to 3 as anticipated, instead a competition between steric effects and intramolecular interactions causes 3 to display distortion intermediate of 1 and 2.PostprintPeer reviewe

    Small molecule recognition of mephedrone using an anthracene molecular clip

    Get PDF
    This document is the Accepted Manuscript version of the following article: Kathryn Kellett, J. Hugh Broome, Mire Zloh, Stewart B. Kirton, Suzanne Fergus, Ute Gerhard, Jacqueline Stair, and Kar J. Wallace, ‘Small molecule recognition of mephedrone using an anthracene molecular clip’, Chemical Communications, Vol. 52(47): 7474-7477, 2016. The version of record is available online at DOI: http://dx.doi.org/10.1039/C6CC03404G. Published by the Royal Society of Chemistry.An anthracene molecular probe has been synthesised and shown to target mephedrone, a stimulant drug from the cathinone class of new psychoactive substances (NPS). A protocol has been developed to detect mephedrone via the probe using NMR spectroscopy in a simulated street sample containing two of the most common cutting agents, benzocaine and caffeine.Peer reviewedFinal Accepted Versio
    corecore