982 research outputs found

    Vocalization-associated respiration patterns: thermography-based monitoring and detection of preparation for calling

    Full text link
    Vocal emission requires coordination with the respiratory system. Monitoring the increase in laryngeal pressure, which is needed for vocal production, allows detection of transitions from quiet respiration to vocalization-supporting respiration. Characterization of these transitions could be used to identify preparation for vocal emission and to examine the probability of it manifesting into an actual vocal production event. Specifically, overlaying the subject's respiration with conspecific calls can highlight events of call initiation and suppression, as a means of signalling coordination and avoiding jamming. Here, we present a thermal imaging-based methodology for synchronized respiration and vocalization monitoring of free-ranging meerkats. The sensitivity of this methodology is sufficient for detecting transient changes in the subject's respiration associated with the exertion of vocal production. The differences in respiration are apparent not only during the vocal output, but also prior to it, marking the potential time frame of the respiratory preparation for calling. A correlation between conspecific calls with elongation of the focal subject's respiration cycles could be related to fluctuations in attention levels or in the motivation to reply. This framework can be used for examining the capability for enhanced respiration control in animals during modulated and complex vocal sequences, detecting ‘failed’ vocalization attempts and investigating the role of respiration cues in the regulation of vocal interactions

    The measurement of lubricant-film thickness using ultrasound

    Get PDF
    Ultrasound is reflected from a liquid layer between two solid bodies. This reflection depends on the ultrasonic frequency, the acoustic properties of the liquid and solid, and the layer thickness. If the wavelength is much greater than the liquid-layer thickness, then the response is governed by the stiffness of the layer. If the wavelength and layer thickness are similar, then the interaction of ultrasound with the layer is controlled by its resonant behaviour. This stiffness governed response and resonant response can be used to determine the thickness of the liquid layer, if the other parameters are known. In this paper, ultrasound has been developed as a method to determine the thickness of lubricating films in bearing systems. An ultrasonic transducer is positioned on the outside of a bearing shell such that the wave is focused on the lubricant-film layer. The transducer is used to both emit and receive wide-band ultrasonic pulses. For a particular lubricant film, the reflected pulse is processed to give a reflection-coefficient spectrum. The lubricant-film thickness is then obtained from either the layer stiffness or the resonant frequency. The method has been validated using fluid wedges at ambient pressure between flat and curved surfaces. Experiments on the elastohydrodynamic film formed between a sliding ball and a flat surface were performed. Film-thickness values in the range 50-500 nm were recorded, which agreed well with theoretical film-formation predictions. Similar measurements have been made on the oil film between the balls and outer raceway of a deep-groove ball bearing

    Hookah: Prevalence, Perceived Harmfulness, and Factors Associated with Its Use among College Students

    Get PDF
    Introduction: Given the increased use and availability of hookah among the US college students, coupled with the health risks related to its use, the current study examined awareness and use of hookah among college students as well as what characteristics are related to the use of hookah. Methods: The study utilized a self administered anonymous survey to gather information about hookah use from the students in an undergraduate general education class (n = 108). Results: The survey results indicated that the large majority of students were aware of hookah, and nearly half of them had used hookah more than once. Level of social activity (p = .016) and perceived healthy lifestyle (p = .042) were the independent predictors of hookah use. The use of hookah was perceived as more harmful than alcohol use, but not as harmful as cigarette smoking. Conclusions: The findings of this study can serve as a baseline for further studies on the subject, the results of which can lead to development of preventive programs targeting the populations that are most prone to hookah use

    Bearded dragons (Pogona vitticeps) with reduced scalation lose water faster but do not have substantially different thermal preferences.

    Get PDF
    Whether scales reduce cutaneous evaporative water loss in lepidosaur reptiles (Superorder Lepidosauria) such as lizards and snakes has been a contentious issue for nearly half a century. Furthermore, while many studies have looked at whether dehydration affects thermal preference in lepidosaurs, far fewer have examined whether normally hydrated lepidosaurs can assess their instantaneous rate of evaporative water loss and adjust their thermal preference to compensate in an adaptive manner. We tested both of these hypotheses using three captive-bred phenotypes of bearded dragon (Pogona vitticeps) sourced from the pet trade: ‘Wild Types’ with normal scalation, ‘Leatherbacks’ exhibiting scales of reduced prominence, and scaleless bearded dragons referred to as ‘Silkbacks’. Silkbacks on average lost water evaporatively at about twice the rate that Wild Types did. Leatherbacks on average were closer in their rates of evaporative water loss to Silkbacks than they were to Wild Types. Additionally, very small (at most ~1°C) differences in thermal preference existed between the three phenotypes that were not statistically significant. This suggests a lack of plasticity in thermal preference in response to an increase in rate of evaporative water loss, and may be reflective of a thermal ‘strategy’ as employed by thermoregulating bearded dragons that prioritises immediate thermal benefits over the threat of future dehydration. The results of this study bolster an often-discounted hypothesis regarding the present adaptive function of scales and have implications for the applied fields of animal welfare and conservation.Funding for this research was provided by the Natural Sciences and Engineering Research Council of Canada (Grant RGPIN-2014-05814)

    Auto-calibration of ultrasonic lubricant-film thickness measurements

    Get PDF
    The measurement of oil film thickness in a lubricated component is essential information for performance monitoring and design. It is well established that such measurements can be made ultrasonically if the lubricant film is modelled as a collection of small springs. The ultrasonic method requires that component faces are separated and a reference reflection recorded in order to obtain a reflection coefficient value from which film thickness is calculated. The novel and practically useful approach put forward in this paper and validated experimentally allows reflection coefficient measurement without the requirement for a reference. This involves simultaneously measuring the amplitude and phase of an ultrasonic pulse reflected from a layer. Provided that the acoustic properties of the substrate are known, the theoretical relationship between the two can be fitted to the data in order to yield reflection coefficient amplitude and phase for an infinitely thick layer. This is equivalent to measuring a reference signal directly, but importantly does not require the materials to be separated. The further valuable aspect of this approach, which is demonstrated experimentally, is its ability to be used as a self-calibrating routine, inherently compensating for temperature effects. This is due to the relationship between the amplitude and phase being unaffected by changes in temperature which cause unwanted changes to the incident pulse. Finally, error analysis is performed showing how the accuracy of the results can be optimized. A finding of particular significance is the strong dependence of the accuracy of the technique on the amplitude of reflection coefficient input data used. This places some limitations on the applicability of the technique. © 2008 IOP Publishing Ltd

    An oversimplification of physiological principles leads to flawed macroecological analyses

    Get PDF
    Macrophysiological analyses are useful to predict current and future range limits and improve our understanding of endotherm macroecology, but such analyses too often rely on oversimplifications of endothermic thermoregulatory and energetic physiology, which lessens their applicability. We detail some of the major issues with macrophysiological analyses based on the classic Scholander–Irving model of endotherm energetics in the hope that it will encourage other research teams to more appropriately integrate physiology into macroecological analyses
    • …
    corecore