1,016 research outputs found
Historicism
As the rebuilding of Berlin’s eighteenth-century Stadtschloss nears completion, German History turns its attention to the phenomenon of historicism: to the recreation of historical artefacts and practices (sometimes at astonishing expense). Historicism reached its high point in the nineteenth century, when individuals and communities turned to the medieval period to address some of the challenges of modernization. But the urge to revive extended back into the medieval period itself and continues into the twenty-first century. What motivated and what continues to motivate such recreations? As a theme, historicism provides an opportunity for fruitful dialogue between premodern and modern scholars. It also challenges us as historians to consider the value of revivals, whether produced by Berlin politicians, by Hollywood filmmakers or by medieval re-enactors. What happens — or what should happen — when academic scholarship encounters..
Исследование закономерностей развития структурно-химической неоднородности в разнородном сварном соединении трубопроводного переходника
Данная работа посвящена исследованию структурно-химической неоднородности (СХН) трубопроводного переходника из разнородных сталей, выполненного аргонодуговой сваркой (АрДС). При помощи оптического микроскопа получены фотографии СХН и ее размеры. СХН выражается в появлении прослоек (карбидной и ферритной) с разным химическим составом. Приведены графики роста ширин прослоек от времени выдержки и температуры.This paper is devoted to the comparison of the structural and chemical inhomogeneity (SCI) of adapters made of dissimilar steels, made by tungsten insert gas (TIG). By means of optical microscope, photographs of the SCI and its dimensions were obtained. SCI is expressed in the appearance of interlayers (carbide and ferritic) with different chemical composition. Graphs of the growth of the widths of the interlayers from the time of exposure and temperature are given
Пористая структура продуктов электрохимического синтеза на переменном токе нанодисперсных оксидов олова
Методами электронной микроскопии и низкотемпературной адсорбции азота изучена пористая структура продуктов электролиза металлического олова на переменном токе промышленной частоты. Установлено, что продукты синтеза характеризуются высокими значениями удельной площади поверхности и мезапористой структурой. Показано, что средний размер частиц варьирует в интервале 10…30 нм
Phenomenological theory of the 3 Kelvin phase in Sr2RuO4
We model the 3K-phase of Sr2RuO4 with Ru-metal inclusion as interface state
with locally enhanced transition temperatures. The resulting 3K-phase must have
a different pairing symmetry than the bulk phase of Sr2RuO4, because the
symmetry at the interface is lower than in the bulk. It is invariant under time
reversal and a second transition, in general, above the onset of bulk
superconductivity is expected where time reversal symmetry is broken. The
nucleation of the 3K-phase exhibits a ``capillary effect'' which can lead to
frustration phenomena for the superconducting states on different
Ru-inclusions. Furthermore, the phase structure of the pair wave function gives
rise to zero-energy quasiparticle states which would be visible in
quasiparticle tunneling spectra. Additional characteristic properties are
associated with the upper critical field Hc2. The 3K-phase has a weaker
anisotropy of Hc2 between the inplane and z-axis orientation than the bulk
superconducting phase. This is connected with the more isotropic nature
Ru-metal which yields a stronger orbital depairing effect for the inplane
magnetic field than in the strongly layered Sr$_2RuO4. An anomalous temperature
dependence for the z-axis critical field is found due to the coupling of the
magnetic field to the order parameter texture at the interface. Various other
experiments are discussed and new measurements are suggested.Comment: 10 pages, 5 figure
Effect of transport-induced charge inhomogeneity on point-contact Andreev reflection spectra at ferromagnet-superconductor interfaces
We investigate the transport properties of a ferromagnet-superconductor
interface within the framework of a modified three-dimensional
Blonder-Tinkham-Klapwijk formalism. In particular, we propose that charge
inhomogeneity forms via two unique transport mechanisms, namely, evanescent
Andreev reflection and evanescent quasiparticle transmission. Furthermore, we
take into account the influence of charge inhomogeneity on the interfacial
barrier potential and calculate the conductance as a function of bias voltage.
Point-contact Andreev reflection (PCAR) spectra often show dip structures,
large zero-bias conductance enhancement, and additional zero-bias conductance
peak. Our results indicate that transport-induced charge inhomogeneity could be
a source of all these anomalous characteristics of the PCAR spectra.Comment: 9 pages, 6 figure
First Observation of a Stable Highly Dissipative Divertor Plasma Regime on the Wendelstein 7-X Stellarator
Strong Anisotropy in Spin Suceptibility of Superfluid 3He-B Film Caused by Surface Bound States
Spin susceptibility of superfluid 3He-B film with specular surfaces is
calculated. It is shown that, when the magnetic field is applied in a direction
perpendiculr to the film, the suseptibility is significantly enhanced by the
contribution from the surface bound states. No such enhancement is found for
the magnetic field parallel to the film. A simplified model with spatially
constant order parameter is used to elucidate the magnetic properties of the
surface bound states. The Majorana nature of the zero energy bound state is
also mentioned.Comment: 4 pages, 4 figure
Comparison of serious inhaler technique errors made by device-naïve patients using three different dry powder inhalers: a randomised, crossover, open-label study
Background: Serious inhaler technique errors can impair drug delivery to the lungs. This randomised, crossover, open-label study evaluated the proportion of patients making predefined serious errors with Pulmojet compared with Diskus and Turbohaler dry powder inhalers. Methods: Patients ≥18 years old with asthma and/or COPD who were current users of an inhaler but naïve to the study devices were assigned to inhaler technique assessment on Pulmojet and either Diskus or Turbohaler in a randomised order. Patients inhaled through empty devices after reading the patient information leaflet. If serious errors potentially affecting dose delivery were recorded, they repeated the inhalations after watching a training video. Inhaler technique was assessed by a trained nurse observer and an electronic inhalation profile recorder. Results: Baseline patient characteristics were similar between randomisation arms for the Pulmojet-Diskus (n = 277) and Pulmojet-Turbohaler (n = 144) comparisons. Non-inferiority in the proportions of patients recording no nurse-observed serious errors was demonstrated for both Pulmojet versus Diskus, and Pulmojet versus Turbohaler; therefore, superiority was tested. Patients were significantly less likely to make ≥1 nurse-observed serious errors using Pulmojet compared with Diskus (odds ratio, 0.31; 95 % CI, 0.19–0.51) or Pulmojet compared with Turbohaler (0.23; 0.12–0.44) after reading the patient information leaflet with additional video instruction, if required. Conclusions These results suggest Pulmojet is easier to learn to use correctly than the Turbohaler or Diskus for current inhaler users switching to a new dry powder inhaler
Determination of muon momentum in the MicroBooNE LArTPC using an improved model of multiple Coulomb scattering
We discuss a technique for measuring a charged particle's momentum by means
of multiple Coulomb scattering (MCS) in the MicroBooNE liquid argon time
projection chamber (LArTPC). This method does not require the full particle
ionization track to be contained inside of the detector volume as other track
momentum reconstruction methods do (range-based momentum reconstruction and
calorimetric momentum reconstruction). We motivate use of this technique,
describe a tuning of the underlying phenomenological formula, quantify its
performance on fully contained beam-neutrino-induced muon tracks both in
simulation and in data, and quantify its performance on exiting muon tracks in
simulation. Using simulation, we have shown that the standard Highland formula
should be re-tuned specifically for scattering in liquid argon, which
significantly improves the bias and resolution of the momentum measurement.
With the tuned formula, we find agreement between data and simulation for
contained tracks, with a small bias in the momentum reconstruction and with
resolutions that vary as a function of track length, improving from about 10%
for the shortest (one meter long) tracks to 5% for longer (several meter)
tracks. For simulated exiting muons with at least one meter of track contained,
we find a similarly small bias, and a resolution which is less than 15% for
muons with momentum below 2 GeV/c. Above 2 GeV/c, results are given as a first
estimate of the MCS momentum measurement capabilities of MicroBooNE for high
momentum exiting tracks
Noise Characterization and Filtering in the MicroBooNE Liquid Argon TPC
The low-noise operation of readout electronics in a liquid argon time
projection chamber (LArTPC) is critical to properly extract the distribution of
ionization charge deposited on the wire planes of the TPC, especially for the
induction planes. This paper describes the characteristics and mitigation of
the observed noise in the MicroBooNE detector. The MicroBooNE's single-phase
LArTPC comprises two induction planes and one collection sense wire plane with
a total of 8256 wires. Current induced on each TPC wire is amplified and shaped
by custom low-power, low-noise ASICs immersed in the liquid argon. The
digitization of the signal waveform occurs outside the cryostat. Using data
from the first year of MicroBooNE operations, several excess noise sources in
the TPC were identified and mitigated. The residual equivalent noise charge
(ENC) after noise filtering varies with wire length and is found to be below
400 electrons for the longest wires (4.7 m). The response is consistent with
the cold electronics design expectations and is found to be stable with time
and uniform over the functioning channels. This noise level is significantly
lower than previous experiments utilizing warm front-end electronics.Comment: 36 pages, 20 figure
- …
