26 research outputs found

    Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>SPECT/CT combines high resolution anatomical 3D computerized tomography (CT) and single photon emission computerized tomography (SPECT) as functional imaging, which provides 3D information about biological processes into a single imaging modality. The clinical utility of SPECT/CT imaging has been recognized in a variety of medical fields and most recently in orthopaedics; however, clinical adoption has been limited due to shortcomings of analytical tools available. Specifically, SPECT analyses are mainly qualitative due to variation in overall metabolic uptake among patients. Furthermore, most analyses are done in 2D, although rich 3D data are available. Consequently, it is difficult to quantitatively compare the position, size, and intensity of SPECT uptake regions among patients, and therefore difficult to draw meaningful clinical conclusions.</p> <p>Methods</p> <p>We propose a method for normalizing orthopaedic SPECT/CT data that enables standardised 3D volumetric quantitative measurements and comparison among patients. Our method is based on 3D localisation using clinically relevant anatomical landmarks and frames of reference, along with intensity value normalisation using clinically relevant reference regions. Using the normalised data, we describe a thresholding technique to distinguish clinically relevant hot spots from background activity.</p> <p>Results</p> <p>Using an exemplar comparison of two patients, we demonstrate how the normalised, 3D-rendered data can provide a richer source of clinical information and allow quantitative comparison of SPECT/CT measurements across patients. Specifically, we demonstrate how non-normalized SPECT/CT analysis can lead to different clinical conclusions than the normalized SPECT/CT analysis, and that normalized quantitative analysis can be a more accurate indicator of pathology.</p> <p>Conclusions</p> <p>Conventional orthopaedic frames of reference, 3D volumetric data analysis and thresholding are used to distinguish clinically relevant hot spots from background activity. Our goal is to facilitate a standardised approach to quantitative data collection and comparison of clinical studies using SPECT/CT, enabling more widespread clinical use of this powerful imaging tool.</p

    18F-FDG PET/CT for diagnosing infectious complications in patients with severe neutropenia after intensive chemotherapy for haematological malignancy or stem cell transplantation

    Get PDF
    Item does not contain fulltextPURPOSE: Between 30 and 50% of febrile neutropenic episodes are accounted for by infection. C-reactive protein (CRP) is a nonspecific parameter for infection and inflammation but might be employed as a trigger for diagnosis. The aim of the study was to evaluate whether (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT can be used to detect inflammatory foci in neutropenic patients with elevated CRP and whether it helps to direct treatment. METHODS: Twenty-eight consecutive patients with neutropenia as a result of intensive chemotherapy for haematological malignancies or myeloablative therapy for haematopoietic stem cell transplantation were prospectively included. (18)F-FDG PET/CT was added to the regular diagnostic workup once the CRP level rose above 50 mg/l. RESULTS: Pathological FDG uptake was found in 26 of 28 cases despite peripheral neutrophil counts less than 0.1 x 10(-9)/l in 26 patients: in the digestive tract in 18 cases, around the tract of the central venous catheter (CVC) in 9 and in the lungs in 7 cases. FDG uptake in the CVC tract was associated with coagulase-negative staphylococcal bacteraemia (p < 0.001) and deep venous thrombosis (p = 0.002). The number of patients having Streptococcus mitis bacteraemia appeared to be higher in patients with grade 3 oesophageal FDG uptake (p = 0.08). Pulmonary FDG uptake was associated with the presence of invasive fungal disease (p = 0.04). CONCLUSION: (18)F-FDG PET/CT scanning during chemotherapy-induced febrile neutropenia and increased CRP is able to detect localized foci of infection and inflammation despite the absence of circulating neutrophils. Besides its potential role in detecting CVC-related infection during febrile neutropenia, the high negative predictive value of (18)F-FDG PET/CT is important for avoiding unnecessary diagnostic tests and therapy.1 januari 201

    Effect of blood glucose level on standardized uptake value (SUV) in F-18- FDG PET-scan : a systematic review and meta-analysis of 20,807 individual SUV measurements

    Get PDF
    Objectives To evaluate the effect of pre-scan blood glucose levels (BGL) on standardized uptake value (SUV) in F-18-FDG-PET scan. Methods A literature review was performed in the MEDLINE, Embase, and Cochrane library databases. Multivariate regression analysis was performed on individual datum to investigate the correlation of BGL with SUVmax and SUVmean adjusting for sex, age, body mass index (BMI), diabetes mellitus diagnosis, F-18-FDG injected dose, and time interval. The ANOVA test was done to evaluate differences in SUVmax or SUVmean among five different BGL groups (200 mg/dl). Results Individual data for a total of 20,807 SUVmax and SUVmean measurements from 29 studies with 8380 patients was included in the analysis. Increased BGL is significantly correlated with decreased SUVmax and SUVmean in brain (p <0.001, p <0.001,) and muscle (p <0.001, p <0.001) and increased SUVmax and SUVmean in liver (p = 0.001, p = 0004) and blood pool (p=0.008, p200 mg/dl had significantly lower SUVmax. Conclusion If BGL is lower than 200mg/dl no interventions are needed for lowering BGL, unless the liver is the organ of interest. Future studies are needed to evaluate sensitivity and specificity of FDG-PET scan in diagnosis of malignant lesions in hyperglycemia.Peer reviewe

    Lymphoscintigraphy and SPECT/CT using 99mTc filtered sulphur colloid in chylothorax.

    No full text
    Item does not contain fulltext1 september 201

    Safety and immunogenicity of three doses of a Neisseria meningitidis A + C diphtheria conjugate vaccine in infants from Niger

    No full text
    Background : High rates of endemic disease and recurrent epidemics of serogroup A and C meningococcal meningitis continue to occur in sub-Saharan Africa. A meningococcal A+ + C polysaccharide diptheria-toxoid-conjugated vaccine may address this issue. Methods : In Niger three doses of a bivalent meningococcal A + C diphtheria-toxoid-conjugated vaccine (MenD), containing 1, 4 or 16 micrometer grams of each polysaccharide per dose, administered at 6, 10 and 14 weeks of age, were compared with #Haemophilus influenzaetypebtetanustoxoidconjugated(PRPT)vaccinegivenwiththesamescheduleorwithameningococcalA+Cpolysacharidevaccine(MenPS)givenat10and14weeksofage.Onebloodsamplewastakenatthetimeofenrollment(6weeksofage)andanotherwastaken4weeksaftertheprimaryseries.Results:alldosesofMenDwerewelltolerated.AftertheprimaryseriesahigherproportionofinfantshaddetectableserumbactericidalactivityagainstserogroupAforeachdoseofMenD(from94 type b-tetanus toxoid-conjugated (PRP-T) vaccine given with the same schedule or with a meningococcal A + C polysacharide vaccine (MenPS) given at 10 and 14 weeks of age. One blood sample was taken at the time of enrollment (6 weeks of age) and another was taken 4 weeks after the primary series. Results : all doses of MenD were well-tolerated. After the primary series a higher proportion of infants had detectable serum bactericidal activity against serogroup A for each dose of MenD (from 94% to 100%) than for MenPS (31%) or #H. influenzae type b-tetanus toxoid-conjuugated vaccine (18.9%) ; P is less than or equal to 0.05. Significant differences were also observed for serogroup C MenD 4 micrometer grams or MenD 16 micrometer grams (100%) vs. MenPS (69.7%) or #Haemophilus influenzae$ type b-tetanus toxoid-conjugated vaccine (24.3%) ; P is less than or equal to 0.05. When MenPS vaccine was given to 11-month children, the immune response measured by both enzyme-linked immunosorbent assay and serum bactericidal assay was greater in those previously immunized with MenD than in those immunized with MenPS vaccine. Conclusion : MenD was safe among infants in Niger, and immunization led to significantly greater functional antibody activity than with MenPS. The 4-micrometer gram dose of MedD for both the A and C serogroups has been selected for further studies. (Résumé d'auteur

    Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT) : clinical value for the knee surgeons?

    No full text
    Single-photon emission computerized tomography in combination with conventional computer tomography (SPECT/CT) is an emerging technology that may hold great clinical value to the orthopaedic knee surgeon. Post-operative knee pain is a familiar condition seen in most orthopaedic clinics. Here, we present the value of SPECT/CT in three such cases of pain after surgical treatment of knee osteoarthritis (high tibial osteotomy, medial unicompartmental arthroplasty, total knee arthroplasty). In these patients with post-operative knee pain, SPECT/CT has proved to be beneficial in establishing the diagnosis and providing guidance for further treatment
    corecore