12 research outputs found

    Simulation based investigation of source-detector configurations for non-invasive fetal pulse oximetry

    Get PDF
    Transabdominal fetal pulse oximetry is a method to monitor the oxygen supply of the unborn child non-invasively. Due to the measurement setup, the received signal of the detector is composed of photons coding purely maternal and photons coding mixed fetal-maternal information. To analyze the wellbeing of the fetus, the fetal signal is extracted from the mixed component. In this paper we assess source-detector configurations, such that the mixed fetal-maternal components of the acquired signals are maximized. Monte-Carlo method is used to simulate light propagation and photon distribution in tissue. We use a plane layer and a spherical layer geometry to model the abdomen of a pregnant woman. From the simulations we extracted the fluence at the detector side for several source-detector distances and analyzed the ratio of the mixed fluence component to total fluence. Our simulations showed that the power of the mixed component depends on the source-detector distance as expected. Further we were able to visualize hot spot areas in the spherical layer model where the mixed fluence ratio reaches the highest level. The results are of high importance for sensor design considering signal composition and quality for non-invasive fetal pulse oximetry

    Principle study on the signal connection at transabdominal fetal pulse oximetry

    Get PDF
    Transabdominal fetal pulse oximetry is an approach to measure oxygen saturation of the unborn child non-invasively. The principle of pulse oximetry is applied to the abdomen of a pregnant woman, such that the measured signal includes both, the maternal and the fetal pulse curve. One of the major challenges is to extract the shape of the fetal pulse curve from the mixed signal for computation of the oxygen saturation. In this paper we analyze the principle kind of connection of the fetal and maternal pulse curves in the measured signal. A time varying finite element model is used to rebuild the basic measurement environment, including a bulk tissue and two independently pulsing arteries to model the fetal and maternal blood circuit. The distribution of the light fluence rate in the model is computed by applying diffusion equation. From the detectors we extracted the time dependent fluence rate and analyzed the signal regarding its components. The frequency spectra of the signals show peaks at the fetal and maternal basic frequencies. Additional signal components are visible in the spectra, indicating multiplicative coupling of the fetal and maternal pulse curves. We conclude that the underlying signal model of algorithms for robust extraction of the shape of the fetal pulse curve, have to consider additive and multiplicative signal coupling

    Numerische Methode zur Bestimmung der Fahrwerkskonfiguration aus Baukastenkomponenten

    Get PDF
    Numerische Methode zur Bestimmung der Fahrwerkskonfiguration aus Baukastenkomponente

    Development of a phantom to modulate the maternal and fetal pulse curve for pulse oximetry measurements

    Get PDF
    For getting reliable information about the state of health from the fetus and the mother during labor and delivery, a fetal pulse oximeter is being developed. This paper describes the development of a special phantom to verify the algorithms for separating the weak fetal from the dominant maternal optical signal. To reach a realistic behavior it is necessary for two circulations to be controlled independently. Inspired by the natural blood circulation behavior, a RC-System with fixed resistance and capacity was created. Pumping a liquid with a roller pump into the tubes widens them. The digital signal processor (DSP) controls the expansion of the tube diameter by modifying the rotation velocity of the pump for active regulation. Therefore a soft and good enlargeable material was used. The measured values of the pressure sensor enabled active feedback for motor control The determined system characteristics are used to adapt the given pulse curve to the real system behavior. Via a LabView interface it is possible to change curve parameters like amplitude and frequency. The goal was to replicate the pulsation of the blood vessels like in the abdomen of a pregnant woman. Changing the parameters influences the modulation of the signal under consideration of the transfer function. With this phantom it is possible to simulate different scenarios, for example different states of pregnancy or pathogen indications

    Improved FPGA controlled artificial vascular system for plethysmographic measurements

    Get PDF
    The fetal oxygen saturation is an important parameter to determine the health status of a fetus, which is until now mostly acquired invasively. The transabdominal, fetal pulse oximetry is a promising approach to measure this non-invasively and continuously. The fetal pulse curve has to be extracted from the mixed signal of mother and fetus to determine its oxygen saturation. For this purpose efficient algorithms are necessary, which have to be evaluated under constant and reproducable test conditions. This paper presents the improved version of a phantom which can generate artificial pulse waves in a synthetic tissue phantom. The tissue phantom consists of several layers that mimic the different optical properties of the fetal and maternal tissue layers. Additionally an artificial vascular system and a dome, which mimics the bending of the belly of a pregnant woman, are incorporated. To obtain data on the pulse waves, several measurement methods are included, to help understand the behavior of the signals gained from the pulse waves. Besides pressure sensors and a transmissive method we integrated a capacitive approach, that makes use of the so called “Pin Oscillator” method. Apart from the enhancements in the tissue phantom and the measurements, we also improved the used blood substitute, which reproduces the different absorption characteristics of fetal and maternal blood. The results show that the phantom can generate pulse waves similar to the natural ones. Furthermore, the phantom represents a reference that can be used to evaluate the algorithms for transabdominal, fetal pulse oximetry

    FPGA controlled artificial vascular system

    Get PDF
    Monitoring the oxygen saturation of an unborn child is an invasive procedure, so far. Transabdominal fetal pulse oximetry is a promising method under research, used to estimate the oxygen saturation of a fetus noninvasively. Due to the nature of the method, the fetal information needs to be extracted from a mixed signal. To properly evaluate signal processing algorithms, a phantom modeling fetal and maternal blood circuits and tissue layers is necessary. This paper presents an improved hardware concept for an artificial vascular system, utilizing an FPGA based CompactRIO System from National Instruments. The experimental model to simulate the maternal and fetal blood pressure curve consists of two identical hydraulic circuits. Each of these circuits consists of a pre-pressure system and an artificial vascular system. Pulse curves are generated by proportional valves, separating these two systems. The dilation of the fetal and maternal artificial vessels in tissue substitutes is measured by transmissive and reflective photoplethysmography. The measurement results from the pressure sensors and the transmissive optical sensors are visualized to show the functionality of the pulse generating systems. The trigger frequency for the maternal valve was set to 1 per second, the fetal valve was actuated at 0.7 per second for validation. The reflective curve, capturing pulsations of the fetal and maternal circuit, was obtained with a high power LED (905 nm) as light source. The results show that the system generates pulse curves, similar to its physiological equivalent. Further, the acquired reflective optical signal is modulated by the alternating diameter of the tubes of both circuits, allowing for tests of signal processing algorithms

    Numerische Methode zur Bestimmung der Fahrwerkskonfiguration aus Baukastenkomponenten

    Get PDF
    Numerische Methode zur Bestimmung der Fahrwerkskonfiguration aus Baukastenkomponente

    Principle study on the signal connection at transabdominal fetal pulse oximetry

    No full text
    Transabdominal fetal pulse oximetry is an approach to measure oxygen saturation of the unborn child non-invasively. The principle of pulse oximetry is applied to the abdomen of a pregnant woman, such that the measured signal includes both, the maternal and the fetal pulse curve. One of the major challenges is to extract the shape of the fetal pulse curve from the mixed signal for computation of the oxygen saturation. In this paper we analyze the principle kind of connection of the fetal and maternal pulse curves in the measured signal. A time varying finite element model is used to rebuild the basic measurement environment, including a bulk tissue and two independently pulsing arteries to model the fetal and maternal blood circuit. The distribution of the light fluence rate in the model is computed by applying diffusion equation. From the detectors we extracted the time dependent fluence rate and analyzed the signal regarding its components. The frequency spectra of the signals show peaks at the fetal and maternal basic frequencies. Additional signal components are visible in the spectra, indicating multiplicative coupling of the fetal and maternal pulse curves. We conclude that the underlying signal model of algorithms for robust extraction of the shape of the fetal pulse curve, have to consider additive and multiplicative signal coupling

    Numerische Methode zur Bestimmung der Fahrwerkskonfiguration aus Baukastenkomponenten

    No full text
    Numerische Methode zur Bestimmung der Fahrwerkskonfiguration aus Baukastenkomponente

    Lead field theory provides a powerful tool for designing microelectrode array impedance measurements for biological cell detection and observation

    Get PDF
    Abstract Background Our aim is to introduce a method to enhance the design process of microelectrode array (MEA) based electric bioimpedance measurement systems for improved detection and viability assessment of living cells and tissues. We propose the application of electromagnetic lead field theory and reciprocity for MEA design and measurement result interpretation. Further, we simulated impedance spectroscopy (IS) with two- and four-electrode setups and a biological cell to illustrate the tool in the assessment of the capabilities of given MEA electrode constellations for detecting cells on or in the vicinity of the microelectrodes. Results The results show the power of the lead field theory in electromagnetic simulations of cell–microelectrode systems depicting the fundamental differences of two- and four-electrode IS measurement configurations to detect cells. Accordingly, the use in MEA system design is demonstrated by assessing the differences between the two- and four-electrode IS configurations. Further, our results show how cells affect the lead fields in these MEA system, and how we can utilize the differences of the two- and four-electrode setups in cell detection. The COMSOL simulator model is provided freely in public domain as open source. Conclusions Lead field theory can be successfully applied in MEA design for the IS based assessment of biological cells providing the necessary visualization and insight for MEA design. The proposed method is expected to enhance the design and usability of automated cell and tissue manipulation systems required for bioreactors, which are intended for the automated production of cell and tissue grafts for medical purposes. MEA systems are also intended for toxicology to assess the effects of chemicals on living cells. Our results demonstrate that lead field concept is expected to enhance also the development of such methods and devices
    corecore