54 research outputs found
Influence of germination on lectin in Lens culinaris seeds
The effect of germination conditions on the lectin of Lens culinaris var. Magda 20 seeds was studied. The seeds were germinated at 20 °C under different conditions of watering and light and for different periods of time. The seed lectin was assayed by haemagglutination and quantified by competitive ELISA. Changes in lectin content during germination were also monitored by SDS-PAGE and immunoblotting. Haemagglutinating activity and lectin content in the seeds were not changed during the first three days regardless of the conditions of the germination. However, lectin concentration was significantly higher after six days of germination; relative lectin levels being particularly high when germination was carried out in the light and with daily watering. The results of SDS-PAGE and immunoblotting have also shown that the lectin was not degraded during the first six days of germination however, other storage-proteins were broken down by proteolysis
Recent Upgrades of the Gas Handling System for the Cryogenic Stopping Cell of the FRS Ion Catcher
In this paper, the major upgrades and technical improvements of the buffer
gas handling system for the cryogenic stopping cell of the FRS Ion Catcher at
GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include
implementation of new gas lines and gas purifiers to achieve a higher buffer
gas cleanliness for a more efficient extraction of reactive ions as well as
suppression of the molecular background ionized in the stopping cell.
Furthermore, additional techniques have been implemented for improved
monitoring and quantification of the purity of the helium buffer gas
Mass Measurements of Neutron-Rich Gallium Isotopes Refine Production of Nuclei of the First r-Process Abundance Peak in Neutron Star Merger Calculations
We report mass measurements of neutron-rich Ga isotopes Ga with
TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The measurements
determine the masses of Ga in good agreement with previous
measurements. The masses of Ga and Ga were measured for the first
time. Uncertainties between keV were reached. The new mass values
reduce the nuclear uncertainties associated with the production of A
84 isotopes by the \emph{r}-process for astrophysical conditions that might be
consistent with a binary neutron star (BNS) merger producing a blue kilonova.
Our nucleosynthesis simulations confirm that BNS merger may contribute to the
first abundance peak under moderate neutron-rich conditions with electron
fractions
Mass and half-life measurements of neutron-deficient iodine isotopes
Neutron-deficient iodine isotopes, 116I and 114I, were produced at relativistic energies by in-flight fragmentation at the Fragment Separator (FRS) at GSI. The FRS Ion Catcher was used to thermalize the ions and to perform highly accurate mass measurements with a Multiple-Reflection Time-of-Flight Mass-Spectrometer (MR-TOF-MS). The masses of both isotopes were measured directly for the first time. The half-life of the 114I was measured by storing the ions in an RF quadrupole for different storage times and counting the remaining nuclei with the MR-TOF-MS. The measured half-life was used to assign the ground state to the measured 114I ions. Predictions on the possible α-decay branch for 114I are presented based on the reduced uncertainties obtained for the Qα-value. Systematic studies of the mass surface were performed with the newly obtained masses, showing better agreement with the expected trend in this mass region.peerReviewe
Mass measurements of As, Se and Br nuclei and their implication on the proton-neutron interaction strength towards the N=Z line
Mass measurements of the nuclides 69As, 70,71Se, and 71Br, produced via fragmentation of a 124Xe primary beam at the Fragment Separator (FRS) at GSI, have been performed with the multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) of the FRS Ion Catcher with an unprecedented mass resolving power of almost 1000000. Such high resolving power is the only way to achieve accurate results and resolve overlapping peaks of short-lived exotic nuclei, whose total number of accumulated events is always limited. For the nuclide 69As, this is the first direct mass measurement. A mass uncertainty of 22 keV was achieved with only ten events. For the nuclide 70Se, a mass uncertainty of 2.6 keV was obtained, corresponding to a relative accuracy of ÎŽm/m=4.0Ă10â8, with less than 500 events. The masses of the nuclides 71Se and 71Br have been measured with an uncertainty of 23 and 16 keV, respectively. Our results for the nuclides 70,71Se and 71Br are in good agreement with the 2016 Atomic Mass Evaluation, and our result for the nuclide 69As resolves the discrepancy between the previous indirect measurements. We measured also the mass of the molecule 14N15N40Ar (A=69) with a relative accuracy of ÎŽm/m=1.7Ă10â8, the highest yet achieved with an MR-TOF-MS. Our results show that the measured restrengthening of the proton-neutron interaction (ÎŽVpn) for odd-odd nuclei along the N=Z line above Z=29 (recently extended to Z=37) is hardly evident at the NâZ=2 line, and not evident at the NâZ=4 line. Nevertheless, detailed structure of ÎŽVpn along the NâZ=2 and NâZ=4 lines, confirmed by our mass measurements, may provide a hint regarding the ongoing â500 keV discrepancy in the mass value of the nuclide 70Br, which prevents including it in the world average of Ft value for superallowed 0+â0+ÎČ decays. The reported work sets the stage for mass measurements with the FRS Ion Catcher of nuclei at and beyond the N=Z line in the same region of the nuclear chart, including the nuclide 70Br.peerReviewe
A Compact Dication Source for Ba Tagging and Heavy Metal Ion Sensor Development
We present a tunable metal ion beam that delivers controllable ion currents
in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed
by sequential atomic evaporation and single or multiple electron impact
ionization, followed by acceleration into a sensing region. Controllability of
the ionic charge state is achieved through tuning of electrode potentials that
influence the retention time in the ionization region. Barium, lead, and cobalt
samples have been used to test the system, with ion currents identified and
quantified using a quadrupole mass analyzer. Realization of a clean
ion beam within a bench-top system represents an important
technical advance toward the development and characterization of barium tagging
systems for neutrinoless double beta decay searches in xenon gas. This system
also provides a testbed for investigation of novel ion sensing methodologies
for environmental assay applications, with dication beams of Pb and
Cd also demonstrated for this purpose
Ba+2 ion trapping using organic submonolayer for ultra-low background neutrinoless double beta detector
If neutrinos are their own antiparticles the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay can occur. The very long lifetime expected for these exceptional events makes its detection a daunting task. In order to conduct an almost background-free experiment, the NEXT collaboration is investigating novel synthetic molecular sensors that may capture the Ba dication produced in the decay of certain Xe isotopes in a high-pressure gas experiment. The use of such molecular detectors immobilized on surfaces must be explored in the ultra-dry environment of a xenon gas chamber. Here, using a combination of highly sensitive surface science techniques in ultra-high vacuum, we demonstrate the possibility of employing the so-called Fluorescent Bicolor Indicator as the molecular component of the sensor. We unravel the ion capture process for these molecular indicators immobilized on a surface and explain the origin of the emission fluorescence shift associated to the ion trapping
NEXT-CRAB-0: A High Pressure Gaseous Xenon Time Projection Chamber with a Direct VUV Camera Based Readout
The search for neutrinoless double beta decay () remains one
of the most compelling experimental avenues for the discovery in the neutrino
sector. Electroluminescent gas-phase time projection chambers are well suited
to searches due to their intrinsically precise energy
resolution and topological event identification capabilities. Scalability to
ton- and multi-ton masses requires readout of large-area electroluminescent
regions with fine spatial resolution, low radiogenic backgrounds, and a
scalable data acquisition system. This paper presents a detector prototype that
records event topology in an electroluminescent xenon gas TPC via VUV
image-intensified cameras. This enables an extendable readout of large tracking
planes with commercial devices that reside almost entirely outside of the
active medium.Following further development in intermediate scale
demonstrators, this technique may represent a novel and enlargeable method for
topological event imaging in .Comment: 32 Pages, 22 figure
Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions
NEXT-100 is currently being constructed at the Laboratorio Subterr\'aneo de
Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta
decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg
of xenon. Charge amplification is carried out via electroluminescence (EL)
which is the process of accelerating electrons in a high electric field region
causing secondary scintillation of the medium proportional to the initial
charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal
meshes of 1 m diameter. This paper describes the design, characterization, and
installation of these parts for NEXT-100. Simulations of the electric field are
performed to model the drift and amplification of ionization electrons produced
in the detector under various EL region alignments and rotations. Measurements
of the electrostatic breakdown voltage in air characterize performance under
high voltage conditions and identify breakdown points. The electrostatic
deflection of the mesh is quantified and fit to a first-principles mechanical
model. Measurements were performed with both a standalone test EL region and
with the NEXT-100 EL region before its installation in the detector. Finally,
we describe the parts as installed in NEXT-100, following their deployment in
Summer 2023.Comment: 35 pages, 25 Figures, update includes accepted version in JINS
- âŠ