34 research outputs found
Recommended from our members
Sonography and Magnetic Resonance Imaging Characteristics of Testicular Adrenal Rest Tumors
Summary Background: The aim of this study was to describe the gray-scale and color Doppler ultrasonography (US) and magnetic resonance (MR) imaging features of testicular adrenal rest tumors (TART) in patients with congenital adrenal hyperplasia. Material/Methods Forty-one patients with congenital adrenal hyperplasia were evaluated by gray-scale and color Doppler ultrasonography. Totally eighteen adrenal rest tumors in 9 patients were diagnosed TART on US and MR imaging. Gray-scale and color Doppler US and MR findings of the patients were documented. Results: A total of eighteen masses were evaluated in nine patients. The mean age of these patients was 14.3±4.5 (range 10.1–23.3) years. US revealed hypoechoic lesions around the mediastinum testis with hypervascularity dispersing in ten patients and hypovascularity in two patients. In six patients, the lesions were hyperechoic with poor vascularity. Lesions exhibited homogeneous (n=8) and heterogeneous (n=10). Testicular microlithiasis was present in 4 of 9 patients with TART. Doppler ultrasound showed normal testicular vessels passing through the mass which were undisturbed, not displaced and not change in caliber. MRI features were the following: all lesions were hypointense on T2- and hyperintense (n=12) and isointense (n=6) on T1-weighted images. All masses revealed homogeneous contrast enhancement on postcontrast T1-weighted images. Conclusions: Ultrasonography and MRI are good methods for detecting and monitoring TART. US is the first preferable modality because it is quick and cheap than MRI. Bilateral mostly hypoechoic lesions depicted around the mediastinum testis with no mass effect is highly suggestive for the diagnosis of testicular adrenal rest tissues on ultrasonography. Normal testicular vessels coursing through the lesions undisturbed and not change in caliber is described specific for this kind of tumors
Comparison of myocardial fibrosis quantification methods by cardiovascular magnetic resonance imaging for risk stratification of patients with suspected myocarditis
Abstract
Background
Although the presence of late gadolinium enhancement (LGE) using cardiovascular magnetic resonance imaging (CMR) is a significant discriminator of events in patients with suspected myocarditis, no data are available on the optimal LGE quantification method.
Methods
Six hundred seventy consecutive patients (48 ± 16 years, 59% male) with suspected myocarditis were enrolled between 2002 and 2015. We performed LGE quantitation using seven different signal intensity thresholding methods based either on 2, 3, 4, 5, 6, 7 standard deviations (SD) above remote myocardium or full width at half maximum (FWHM). In addition, a LGE visual presence score (LGE-VPS) (LGE present/absent in each segment) was assessed. For each of these methods, the strength of association of LGE results with major adverse cardiac events (MACE) was determined. Inter-and intra-rater variability using intraclass-correlation coefficient (ICC) was performed for all methods.
Results
Ninety-eight (15%) patients experienced a MACE at a medium follow-up of 4.7 years. LGE quantification by FWHM, 2- and 3-SD demonstrated univariable association with MACE (hazard ratio [HR] 1.05, 95% confidence interval [CI]:1.02–1.08, p = 0.001; HR 1.02, 95%CI:1.00–1.04; p = 0.001; HR 1.02, 95%CI: 1.00–1.05, p = 0.035, respectively), whereas 4-SD through 7-SD methods did not reach significant association. LGE-VPS also demonstrated association with MACE (HR 1.09, 95%CI: 1.04–1.15, p < 0.001). In the multivariable model, FWHM, 2-SD methods, and LGE-VPS each demonstrated significant association with MACE adjusted to age, sex, BMI and LVEF (adjusted HR of 1.04, 1.02, and 1.07; p = 0.009, p = 0.035; and p = 0.005, respectively). In these, FWHM and LGE-VPS had the highest degrees of inter and intra-rater reproducibility based on their high ICC values.
Conclusions
FWHM is the optimal semi-automated quantification method in risk-stratifying patients with suspected myocarditis, demonstrating the strongest association with MACE and the highest technical consistency. Visual LGE scoring is a reliable alternative method and is associated with a comparable association with MACE and reproducibility in these patients.
Trial registration number
NCT03470571
. Registered 13th March 2018. Retrospectively registered.https://deepblue.lib.umich.edu/bitstream/2027.42/148145/1/12968_2019_Article_520.pd
Implementation and performance of automated software to compute the RV/LV diameter ratio from CT pulmonary angiography images
Objective: The aim of this study was to prospectively test the performance and potential for clinical integration of software that automatically calculates the right-to-left ventricular (RV/LV) diameter ratio from computed tomography pulmonary angiography images.
Methods: Using 115 computed tomography pulmonary angiography images that were positive for acute pulmonary embolism, we prospectively evaluated RV/LV ratio measurements that were obtained as follows: (1) completely manual measurement (reference standard), (2) completely automated measurement using the software, and (3 and 4) using a customized software interface that allowed 2 independent radiologists to manually adjust the automatically positioned calipers.
Results: Automated measurements underestimated (P < 0.001) the reference standard (1.09 [0.25] vs1.03 [0.35]). With manual correction of the automatically positioned calipers, the mean ratio became closer to the reference standard (1.06 [0.29] by read 1 and 1.07 [0.30] by read 2), and the correlation improved (r = 0.675 to 0.872 and 0.887). The mean time required for manual adjustment (37 [20] seconds) was significantly less than the time required to perform measurements entirely manually (100 [23] seconds).
Conclusions: Automated CT RV/LV diameter ratio software shows promise for integration into the clinical workflow for patients with acute pulmonary embolism
The use of cryoablation in treating liver tumors.
Percutaneous image-guided tumor ablation techniques have been used as an alternative method for patients with unresectable liver tumors. Although all techniques avoid morbidity and mortality of major surgery and have advantage of preserving non-tumoral liver parenchyma, cryoablation currently is the only percutaneous ablation technique allowing intraprocedural monitoring because of visibility of its ablation effect with computed tomography and MRI. Cryoablation uses extremely low temperatures to induce local tissue necrosis to treat both primary and metastatic liver tumors. This article discusses the principles of liver tumor percutaneous cryoablation, including mechanisms of tissue injury, technique, equipment, image-guidance used, patient selection criteria, clinical outcome and complications as well as current trends and future goals
Recommended from our members
Cross-sectional imaging of aortic infections
Aortic infections are uncommon clinical entities, but are associated with a high morbidity and mortality. In this review, we focus on the cross-sectional imaging appearances of aortic infections, including aortic valve endocarditis, pyogenic aortitis, mycotic aneurysm and aortic graft infections, with an emphasis on CT and MRI
Recommended from our members
Alternative Diagnostic Strategy for the Assessment and Treatment of Pulmonary Embolus: A Case Series
Introduction: Ferumoxytol-enhanced magnetic resonance angiography (FeMRA) can be used as an alternate and safe method to diagnose patients with compromised renal function who present with acute pulmonary embolus in the emergency department (ED) setting.Case Report: A 62-year old man with a history of renal transplant and lymphoproliferative disease described new onset of breathlessness. His clinical symptoms were suggestive of pulmonary embolus. He underwent FeMRA in the ED to avoid exposure to intravenous iodinated contrast. FeMRA demonstrated a left main pulmonary artery embolus, which extended to the left interlobar pulmonary artery. Afterward, the patient initiated anticoagulation therapy. With preserved renal function he was able to continue his outpatient chemotherapy regimen.Conclusion: This case highlights a safe imaging technique for emergency physicians to diagnose pulmonary embolus and subsequently guide anticoagulation therapy for patients in whom use of conventional contrast is contraindicated
Quantification of radiation dose reduction by reducing z-axis coverage in 320-detector coronary CT angiography.
OBJECTIVE: To quantify the radiation dose reduction achievable by minimizing z-axis coverage in 320-detector coronary CT angiography (CCTA).
METHODS: We retrospectively reviewed 130 CCTAs performed on 320-detector CT that offers up to 16 cm z-axis coverage (adjustable in 2-cm increments), allowing complete coverage of the heart in a single gantry rotation. For each CT, we obtained the radiation dose [CT dose index and dose-length product (DLP)], measured the z-axis field of view and measured the craniocaudal cardiac size (distance from the left main coronary artery to the cardiac apex). We calculated the radiation dose savings achievable by reducing the z-axis coverage to the minimum necessary to cover the heart using 320 × 0.5-mm (maximum 16 cm) and 256 × 0.5-mm (maximum 12.8 cm) detector collimations.
RESULTS: Results are expressed as mean ± standard deviation. The mean craniocaudal cardiac size was 10.5 ± 1.0 cm, with 85% (n = 112) of CCTAs performed with 16 cm of z-axis coverage. The mean DLP was 417.6 ± 182.4 mGy cm, with the mean DLP saving achievable using the minimum z-axis coverage required to completely image the heart being 96.2 ± 47.4 mGy cm, an average dose reduction of 26.9 ± 7.0%. z-axis coverage of ≤12 cm was adequate for 92% and 12.8 cm for 98% of subjects.
CONCLUSION: Using the minimal z-axis coverage to adequately image the heart is a simple step that can reduce the DLP in 320-detector CCTA by approximately 27%. z-axis coverage of ≤12 cm is adequate for 92%, 12.8 cm for 98% and 14 cm for 100% of patients undergoing CCTA. Advances in knowledge: Reducing z-axis coverage in 320-detector CCTA can reduce DLP by approximately 27%