35 research outputs found

    Reliability of lithium dilution cardiac output in anaesthetized sheep

    Get PDF
    Background Cardiac output (CO) measurement with lithium dilution (COLD) has not been fully validated in sheep using precise ultrasonic flow probe technology (COUFP). Sheep generate important cardiovascular research models and the use of COLD has become more popular in experimental settings. Methods Ultrasonic transit-time perivascular flow probes were surgically implanted on the pulmonary artery of 13 sheep. Paired COLD readings were taken at six time points, before and after implantation of a left ventricular assist device (LVAD) and compared with COUFP recorded just after lithium injection. Results The mean COLD was 5.7 litre min−1 (range 3.8-9.6 litre min−1) and mean COUFP 5.9 litre min−1 (range 4.0-9.2 litre min−1). The bias (standard deviation) was 0.3 (1.0) litre min−1 [5.1 (16.9)%] and limits of agreement (LOA) were −1.7 to 2.3 litre min−1 (−28.8 to 39.0%) with a percentage error (PE) of 34.4%. Data to assess trending [rate (95% confidence intervals)] included a 78 (62-93)% concordance rate in the four-quadrant plot (n=27). In the half moon polar plot (n=19), the mean polar angle was +5°, the radial LOA were −49 to +35° and 68 (47-89)% of data points fell within 22.5° of the mean polar angle. Both tests indicated moderate to poor trending ability. Conclusion COLD is not precise when evaluated against COUFP in sheep based on the statistical criteria set, but the results are comparable with previously published animal studie

    Reliability of lithium dilution cardiac output in anaesthetized sheep

    Get PDF
    BACKGROUND: Cardiac output (CO) measurement with lithium dilution (COLD) has not been fully validated in sheep using precise ultrasonic flow probe technology (COUFP). Sheep generate important cardiovascular research models and the use of COLD has become more popular in experimental settings. METHODS: Ultrasonic transit-time perivascular flow probes were surgically implanted on the pulmonary artery of 13 sheep. Paired COLD readings were taken at six time points, before and after implantation of a left ventricular assist device (LVAD) and compared with COUFP recorded just after lithium injection. RESULTS: The mean COLD was 5.7 litre min(-1) (range 3.8-9.6 litre min(-1)) and mean COUFP 5.9 litre min(-1) (range 4.0-9.2 litre min(-1)). The bias (standard deviation) was 0.3 (1.0) litre min(-1) [5.1 (16.9)%] and limits of agreement (LOA) were -1.7 to 2.3 litre min(-1) (-28.8 to 39.0%) with a percentage error (PE) of 34.4%. Data to assess trending [rate (95% confidence intervals)] included a 78 (62-93)% concordance rate in the four-quadrant plot (n=27). In the half moon polar plot (n=19), the mean polar angle was +5°, the radial LOA were -49 to +35° and 68 (47-89)% of data points fell within 22.5° of the mean polar angle. Both tests indicated moderate to poor trending ability. CONCLUSION: COLD is not precise when evaluated against COUFP in sheep based on the statistical criteria set, but the results are comparable with previously published animal studies. KEYWORDS

    Comparative oncology and clinical translation of glyco protein conjugated gold nano therapeutic agent (GA-198AuNP) [abstract]

    Get PDF
    Nanoscience Poster SessionAs part of our efforts toward clinical translation of GA-198AuNP, our studies are focused on therapeutic efficacy of nanoparticulate GA198AuNP agent in dogs with prostatic carcinoma. The overall goal is to gain clinical insights on therapeutic efficacy of GA198AuNP in a large animal model. We have performed a phase I clinical trial using GA-AuNP administered intravenously or intratumorally by injection or infusion. CT scans were performed prior to injection and 24 hours post injection in 3 of the 4 dogs. Following injections, dogs were allowed further treatment as recommended by the primary attending clinician. Four dogs have been treated to date. Complications related to GA-AuNP treatment were not observed, and all 4 dogs received adjunctive treatment with radiation therapy and/ or chemotherapy. These preliminary studies have clearly provided compelling evidence on the therapeutic potential of biocompatible GA-AuNP for their utility as novel therapeutic agents in treating various types of inoperable solid tumors. Intra-tumoral and intravenous administration of GA-AuNP is safe in dogs with spontaneously occurring tumors. As further therapeutic efficacy studies continue, the outcome of this clinical trial in a large animal model will generate therapeutic efficacy data which will be used for filing IND application for Phase I clinical trial studies. This clinical translation effort provides significant advances in terms of delivering optimum therapeutic payloads into prostate cancers with subsequent reduction in tumor volume, thus may effectively reduce/eliminate the need for surgical resection. This presentation will include details of clinical translation of GA198AuNP in prostate tumor bearing dogs

    Anaesthesia for castration of piglets: comparison between intranasal and intramuscular application of ketamine, climazolam and azaperone

    No full text
    The aim of this study was to compare the effect of an anaesthetic combination given either intramuscularly (IM) or intranasally (IN) for castration of piglets. Forty piglets aged 4 to 7 days were randomly assigned to receive a mixture of ketamine 15 mg kg-1, climazolam 1.5 mg kg-1 and azaperone 1.0 mg kg-1, IN or IM, 10 minutes prior to castration. Physiological parameters were measured. Castration was videotaped for evaluation by 3 independent observers using a scoring system. Reaction and vocalization to the skin incision and cutting of spermatic cord was evaluated and scored (0 = no reaction, 16 = strong reaction). The IN group had a significantly higher (P < 0.01) castration score, compared to the IM group. There was an association between castration score and room temperature in the IN group (with temperatures below 18 "C associated with a higher castration scores (P < 0.001). Heart rate was significantly higher 10 minutes after castration in the IN group (P < 0.05). Respiratory rate was significantly higher in the IM group at time points -5, -1, 10, 20 and 30 (P < 0.05).The IN group was walking significantly (P < 0.0001) faster than the IM group. In conclusion, this combination provides effective anaesthesia for routine castration of newborn piglets when administered IM. IN administration provided shorter recovery times but had significantly higher castration scores

    Reliability of lithium dilution cardiac output in anaesthetized sheep

    Get PDF
    BACKGROUND: Cardiac output (CO) measurement with lithium dilution (COLD) has not been fully validated in sheep using precise ultrasonic flow probe technology (COUFP). Sheep generate important cardiovascular research models and the use of COLD has become more popular in experimental settings. METHODS: Ultrasonic transit-time perivascular flow probes were surgically implanted on the pulmonary artery of 13 sheep. Paired COLD readings were taken at six time points, before and after implantation of a left ventricular assist device (LVAD) and compared with COUFP recorded just after lithium injection. RESULTS: The mean COLD was 5.7 litre min(-1) (range 3.8-9.6 litre min(-1)) and mean COUFP 5.9 litre min(-1) (range 4.0-9.2 litre min(-1)). The bias (standard deviation) was 0.3 (1.0) litre min(-1) [5.1 (16.9)%] and limits of agreement (LOA) were -1.7 to 2.3 litre min(-1) (-28.8 to 39.0%) with a percentage error (PE) of 34.4%. Data to assess trending [rate (95% confidence intervals)] included a 78 (62-93)% concordance rate in the four-quadrant plot (n=27). In the half moon polar plot (n=19), the mean polar angle was +5°, the radial LOA were -49 to +35° and 68 (47-89)% of data points fell within 22.5° of the mean polar angle. Both tests indicated moderate to poor trending ability. CONCLUSION: COLD is not precise when evaluated against COUFP in sheep based on the statistical criteria set, but the results are comparable with previously published animal studies. KEYWORDS
    corecore