156 research outputs found

    Complex signal recovery from two fractional Fourier transform intensities: order and noise dependence

    Get PDF
    Cataloged from PDF version of article.The problem of recovering a complex signal from the magnitudes of two of its fractional Fourier transforms is addressed. This corresponds to phase retrieval from the transverse intensity profiles of an optical field at two arbitrary locations along the optical axis. The convergence of the iterative algorithm, the effects of noise or measurement errors, and their dependence on the fractional transform order are investigated. It is observed that in general, better results are obtained when the fractional transform order is close to unity and poorer results are obtained when the order is close to zero. It follows that to the extent that conditions allow, the fractional order between the two measurement planes should be chosen as close to unity (or other odd integer) as possible for best results. (C) 2004 Elsevier B.V. All rights reserved

    Complex signal recovery from multiple fractional Fourier-transform intensities

    Get PDF
    Cataloged from PDF version of article.The problem of recovering a complex signal from the magnitudes of any number of its fractional Fourier transforms at any set of fractional orders is addressed. This problem corresponds to the problem of phase retrieval from the transverse intensity profiles of an optical field at arbitrary locations in an optical system involving arbitrary concatenations of lenses and sections of free space. The dependence of the results on the number of orders, their spread, and the noise is investigated. Generally, increasing the number of orders improves the results, but with diminishing return beyond a certain point. Selecting the measurement planes such that their fractional orders are well separated or spread as much as possible also leads to better results. (c) 2005 Optical Society of Americ

    Life-Threatening Massive Thromboembolism After Laparoscopic Splenectomy in an Idiopathic Thrombocytopenic Patient

    Get PDF
    A life-threatening massive thromboembolism is reported that developed after laparoscopic splenectomy in a 57-year-old female with idiopathic thrombocytopenic purpura (ITP). Although asymptomatic, she underwent splenectomy because of poor response to steroids and intravenous (IV) gamma globulin. Thirteen days after splenectomy, she suffered portal and mesenteric emboli, followed by pulmoner emboli and left popliteal thrombophlebitis. Extensive workup for hypercoagulable states was negative. Low molecular weight heparin (LMWH) was initiated at a suboptimal dose because of thrombocytopenia. During follow-up, her platelet count increased gradually. Whenever the platelet count had remained stable at > 50 x 109/L, she received full dose of LMWH treatment. Over the next 38 days, her pain resolved, she tolerated a full diet, and sent home. Follow-up imaging studies demonstrated a recanalized portal vein and totally resolved pulmonary arteries. We thought that, consumption of platelets in the massive thromboembolism sites including portal, mesenteric and pulmoner vascular beds had resulted in deep thrombocytopenia, which improved gradually with anticoagulant therapy

    Cardiorespiratory effects of venous lipid micro embolization in an experimental model of mediastinal shed blood reinfusion

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Retransfusion of the patient's own blood during surgery is used to reduce the need for allogenic blood transfusion. It has however been found that this blood contains lipid particles, which form emboli in different organs if the blood is retransfused on the arterial side. In this study, we tested whether retransfusion of blood containing lipid micro-particles on the venous side in a porcine model will give hemodynamic effects.</p> <p>Methods</p> <p>Seven adult pigs were used. A shed blood surrogate containing 400 ml diluted blood and 5 ml radioactive triolein was produced to generate a lipid embolic load. The shed blood surrogate was rapidly (<2 minutes) retransfused from a transfusion bag to the right atrium under general anesthesia. The animals' arterial, pulmonary, right and left atrial pressure were monitored, together with cardiac output and deadspace. At the end of the experiment, an increase in cardiac output and pulmonary pressure was pharmacologically induced to try to flush out lipid particles from the lungs.</p> <p>Results</p> <p>A more than 30-fold increase in pulmonary vascular resistance was observed, with subsequent increase in pulmonary artery pressure, and decrease in cardiac output and arterial pressure. This response was transient, but was followed by a smaller, persistent increase in pulmonary vascular resistance. Only a small portion of the infused triolein passed the lungs, and only a small fraction could be recirculated by increasing cardiac output and pulmonary pressure.</p> <p>Conclusion</p> <p>Infusion of blood containing lipid micro-emboli on the venous side leads to acute, severe hemodynamic responses that can be life threatening. Lipid particles will be trapped in the lungs, leading to persistent effects on the pulmonary vascular resistance.</p

    Coding variants in RPL3L and MYZAP increase risk of atrial fibrillation

    Get PDF
    Source at https://doi.org/10.1038/s42003-018-0068-9. Most sequence variants identified hitherto in genome-wide association studies (GWAS) of atrial fibrillation are common, non-coding variants associated with risk through unknown mechanisms. We performed a meta-analysis of GWAS of atrial fibrillation among 29,502 cases and 767,760 controls from Iceland and the UK Biobank with follow-up in samples from Norway and the US, focusing on low-frequency coding and splice variants aiming to identify causal genes. We observe associations with one missense (OR = 1.20) and one splice-donor variant (OR = 1.50) in RPL3L, the first ribosomal gene implicated in atrial fibrillation to our knowledge. Analysis of 167 RNA samples from the right atrium reveals that the splice-donor variant in RPL3L results in exon skipping. We also observe an association with a missense variant in MYZAP (OR = 1.38), encoding a component of the intercalated discs of cardiomyocytes. Both discoveries emphasize the close relationship between the mechanical and electrical function of the heart

    Genetic insight into sick sinus syndrome

    Get PDF
    Aims. The aim of this study was to use human genetics to investigate the pathogenesis of sick sinus syndrome (SSS) and the role of risk factors in its development. Methods and results. We performed a genome-wide association study of 6469 SSS cases and 1 000 187 controls from deCODE genetics, the Copenhagen Hospital Biobank, UK Biobank, and the HUNT study. Variants at six loci associated with SSS, a reported missense variant in MYH6, known atrial fibrillation (AF)/electrocardiogram variants at PITX2, ZFHX3, TTN/CCDC141, and SCN10A and a low-frequency (MAF = 1.1–1.8%) missense variant, p.Gly62Cys in KRT8 encoding the intermediate filament protein keratin 8. A full genotypic model best described the p.Gly62Cys association (P = 1.6 × 10⁻²⁰), with an odds ratio (OR) of 1.44 for heterozygotes and a disproportionally large OR of 13.99 for homozygotes. All the SSS variants increased the risk of pacemaker implantation. Their association with AF varied and p.Gly62Cys was the only variant not associating with any other arrhythmia or cardiovascular disease. We tested 17 exposure phenotypes in polygenic score (PGS) and Mendelian randomization analyses. Only two associated with the risk of SSS in Mendelian randomization, AF, and lower heart rate, suggesting causality. Powerful PGS analyses provided convincing evidence against causal associations for body mass index, cholesterol, triglycerides, and type 2 diabetes (P > 0.05). Conclusion. We report the associations of variants at six loci with SSS, including a missense variant in KRT8 that confers high risk in homozygotes and points to a mechanism specific to SSS development. Mendelian randomization supports a causal role for AF in the development of SSS

    Performance of all-Polypropylene composites at LNG temperatures

    No full text
    In the small scale LNG infrastructure, composite materials are scarcely employed. Potentially, cost effective solutions for LNG applications could be developed thanks to the advantages of composite materials over metals such as weight savings, design flexibility and recyclability. The research presented in this paper focuses on the mechanical performance of fully recyclable, thermoplastic Polypropylene (PP) composite tapes at cryogenic LNG temperatures. Quasi-static tensile tests performed on [±45] laminates made of plain woven plies of PURE® show that at - 196°C the behavior is bilinear with the failure strain of 6.5% and failure stress of 37 MPa. Such non-brittle failure behavior of PP is desirable for cryogenic applications. The other results presented in the paper contains [0/90] laminate results and the interlaminar shear strength characteristics at room and cryogenic temperatures. © Copyright 2017 ASME. Pressure Vessels and Piping Divisio
    corecore