4,817 research outputs found
Accuracy of gravitational physics tests using ranges to the inner planets
A number of different types of deviations from Kepler's laws for planetary orbits can occur in nonNewtonian metric gravitational theories. These include secular changes in all of the orbital elements and in the mean motion, plus additional periodic perturbations in the coordinates. The first order corrections to the Keplerian motion of a single planet around the Sun due to the parameterized post Newtonian theory parameters were calculated as well as the corrections due to the solar quadrupole moment and a possible secular change in the gravitational constant. The results were applied to the case of proposed high accuracy ranging experiments from the Earth to a Mercury orbiting spacecraft in order to see how well the various parameters can be determined
Electrostatic forces for personnel restraints
The feasibility of utilizing electrostatic forces for personnel retention devices on exterior spacecraft surfaces was analyzed. The investigation covered: (1) determination of the state of the art; (2) analysis of potential adhesion surfaces; (3) safety considerations for personnel; (4) electromagnetic force field determination and its effect on spacecraft instrumentation; and (5) proposed advances to current technology based on documentation review, analyses, and experimental test data
Science Goals of the Primary Atomic Reference Clock in Space (PARCS) Experiment
The PARCS (Primary Atomic Reference Clock in Space) experiment will use a laser-cooled Cesium atomic clock operating in the microgravity environment aboard the International Space Station (ISS) to provide both advanced tests of gravitational theory and to demonstrate a new cold-atom clock technology for space. PARCS is a joint project of the National Institute of Standards and Technology (NIST), NASA's Jet Propulsion Laboratory (JPL), and the University of Colorado (CU). This paper concentrates on the scientific goals of the PARCS mission. The microgravity space environment allows laser-cooled Cs atoms to have Ramsey times in excess of those feasible on Earth, resulting in improved clock performance. Clock stabilities of 5x10(exp -14) at one second, and accuracies better than 10(exp -16) are projected
Time outdoors and the prevention of myopia
Recent epidemiological evidence suggests that children who spend more time outdoors are less likely to be, or to become myopic, irrespective of how much near work they do, or whether their parents are myopic. It is currently uncertain if time outdoors also blocks progression of myopia. It has been suggested that the mechanism of the protective effect of time outdoors involves light-stimulated release of dopamine from the retina, since increased dopamine release appears to inhibit increased axial elongation, which is the structural basis of myopia. This hypothesis has been supported by animal experiments which have replicated the protective effects of bright light against the development of myopia under laboratory conditions, and have shown that the effect is, at least in part, mediated by dopamine, since the D2-dopamine antagonist spiperone reduces the protective effect. There are some inconsistencies in the evidence, most notably the limited inhibition by bright light under laboratory conditions of lens-induced myopia in monkeys, but other proposed mechanisms possibly associated with time outdoors such as relaxed accommodation, more uniform dioptric space, increased pupil constriction, exposure to UV light,
changes in the spectral composition of visible light, or increased physical activity have little epidemiological
or experimental support. Irrespective of the mechanisms involved, clinical trials are now underway
to reduce the development of myopia in children by increasing the amount of time they spend outdoors. These trials would benefit from more precise definition of thresholds for protection in terms of intensity and duration of light exposures. These can be investigated in animal experiments in appropriate models, and can also be determined in epidemiological studies, although more precise measurement of exposures than those currently provided by questionnaires is desirable
Low Gain Avalanche Detectors (LGAD) for particle physics and synchrotron applications
A new avalanche silicon detector concept is introduced with a low gain in the region of ten, known as a Low Gain Avalanche Detector, LGAD. The detector's characteristics are simulated via a full process simulation to obtain the required doping profiles which demonstrate the desired operational characteristics of high breakdown voltage (500 V) and a gain of 10 at 200 V reverse bias for X-ray detection. The first low gain avalanche detectors fabricated by Micron Semiconductor Ltd are presented. The doping profiles of the multiplication junctions were measured with SIMS and reproduced by simulating the full fabrication process which enabled further development of the manufacturing process. The detectors are 300 μm thick p-type silicon with a resistivity of 8.5 kΩcm, which fully depletes at 116 V. The current characteristics are presented and demonstrate breakdown voltages in excess of 500 V and a current density of 40 to 100 nAcm−2 before breakdown measured at 20oC. The gain of the LGAD has been measured with a red laser (660 nm) and shown to be between 9 and 12 for an external bias voltage range from 150 V to 300 V
Reclaiming human machine nature
Extending and modifying his domain of life by artifact production is one of
the main characteristics of humankind. From the first hominid, who used a wood
stick or a stone for extending his upper limbs and augmenting his gesture
strength, to current systems engineers who used technologies for augmenting
human cognition, perception and action, extending human body capabilities
remains a big issue. From more than fifty years cybernetics, computer and
cognitive sciences have imposed only one reductionist model of human machine
systems: cognitive systems. Inspired by philosophy, behaviorist psychology and
the information treatment metaphor, the cognitive system paradigm requires a
function view and a functional analysis in human systems design process.
According that design approach, human have been reduced to his metaphysical and
functional properties in a new dualism. Human body requirements have been left
to physical ergonomics or "physiology". With multidisciplinary convergence, the
issues of "human-machine" systems and "human artifacts" evolve. The loss of
biological and social boundaries between human organisms and interactive and
informational physical artifact questions the current engineering methods and
ergonomic design of cognitive systems. New developpment of human machine
systems for intensive care, human space activities or bio-engineering sytems
requires grounding human systems design on a renewed epistemological framework
for future human systems model and evidence based "bio-engineering". In that
context, reclaiming human factors, augmented human and human machine nature is
a necessityComment: Published in HCI International 2014, Heraklion : Greece (2014
Synthetic LISA: Simulating Time Delay Interferometry in a Model LISA
We report on three numerical experiments on the implementation of Time-Delay
Interferometry (TDI) for LISA, performed with Synthetic LISA, a C++/Python
package that we developed to simulate the LISA science process at the level of
scientific and technical requirements. Specifically, we study the laser-noise
residuals left by first-generation TDI when the LISA armlengths have a
realistic time dependence; we characterize the armlength-measurements
accuracies that are needed to have effective laser-noise cancellation in both
first- and second-generation TDI; and we estimate the quantization and
telemetry bitdepth needed for the phase measurements. Synthetic LISA generates
synthetic time series of the LISA fundamental noises, as filtered through all
the TDI observables; it also provides a streamlined module to compute the TDI
responses to gravitational waves according to a full model of TDI, including
the motion of the LISA array and the temporal and directional dependence of the
armlengths. We discuss the theoretical model that underlies the simulation, its
implementation, and its use in future investigations on system characterization
and data-analysis prototyping for LISA.Comment: 18 pages, 14 EPS figures, REVTeX 4. Accepted PRD version. See
http://www.vallis.org/syntheticlisa for information on the Synthetic LISA
software packag
- …