74 research outputs found
A Methodology for the Digitalization of the Residential Building Renovation Process through OpenBIM-Based Workflows
The European building industry is facing a strong increase in renovation processes, which are still non-cost-effective, involve unproperly coordinated stakeholders, are disturbing for the occupants, and cause important inefficiencies in the overall renovation process. In this context, digitalization and Building Information Modelling (BIM), as an enabler, is the key solution that may drive renovation interventions to ensure a more successful and leaner process, aiding the whole value chain of actors to achieve its full potential. This research describes the OpenBIM methodology applied in order to transform the implicit knowledge from the stakeholders involved in the building renovation process, not structured enough for automation, into an OpenBIM digital process based on the BIM standards. The outcomes of this research are the OpenBIM ready workflows that represent the renovation process and information requirements according to the involvement of different stakeholders rooted in the analysis of barriers, requirements, and needs. Those workflows are the basis for the future development of specific products and tools for boosting digitalization and interoperability in the renovation process.This work has been developed within the project BIM4Ren. The project has received funding from the European Union’s Horizon H2020 research and innovation program under Grant Agreement No 820773
Evaluación de herramientas de generación de tráfico malicioso aplicadas a una red IP virtualizada
With the evolution of telecommunications and the passing of the years, it has been seen that companies are increasingly dependent on their network infrastructure, therefore any problem that is generated by the smallest can lead to the collapse of their operations. The lack of protection on the networks is a common problem today, so that an alarming number of cybercriminals have emerged that are increasingly improving their attacking skills, gaining greater profits even infiltrating the same company. The current thesis contains details of a collection of information on computer security and malicious traffic generating tools, being necessary when managing performance and functionality tests of an enterprise network, most of these tools are open source that are available for Be used, modified or improved by the academic community according to their requirements. Subsequently, a virtualized IP network is designed and simulated to demonstrate the attack potential of these tools, an analysis of results to be taken into account in the event of a real attack, concluding with a description of appropriate methods to counteract the different Simulated attacks.Con la evolución de las telecomunicaciones y el pasar de los años, se ha visto que las empresas cada vez dependen más de su infraestructura de red, por consecuencia cualquier problema que se genere por más pequeño que sea puede llegar a colapsar sus operaciones. La falta de protección en las redes es un problema común hoy en día, de tal manera que ha surgido un número alarmante de ciberdelincuentes que cada vez mejoran sus habilidades de ataque obteniendo mayores beneficios incluso infiltrándose en la misma empresa. La actual tesina contiene detalles de una recolección de información sobre seguridad informática y herramientas generadoras de tráfico malicioso, siendo necesarias a la hora de gestionar pruebas de desempeño y funcionalidad de una red empresarial, la mayoría de estas herramientas son de código abierto que están disponibles para poder ser utilizadas, modificadas o mejoradas por la comunidad académica de acuerdo a sus requerimientos. Posteriormente se diseña y simula una red IP virtualizada para poder demostrar el potencial de ataque de dichas herramientas, se realiza un análisis de resultados a tener en cuenta en caso de que suceda un ataque real, concluyendo con una descripción de métodos apropiados para contrarrestar los distintos ataques simulados.Uvidia Armijo, LA. (2017). Evaluación de herramientas de generación de tráfico malicioso aplicadas a una red IP virtualizada. http://hdl.handle.net/10251/91790TFG
Optimization module for filtering and ranking alternative energy replacement systems, in an online ICT design tool for building retrofits
This paper describes the development of an innovative optimizer component as part of a calculation tool for evaluating and comparing a set of retrofitting options for domestic heating and cooling systems. At the initial stage of the process, a filtering sub-module has been developed to pre-process the information introduced by the user and generate a limited set of simulations, thus speeding up the calculation process. At a later stage, the optimizer collects and post-processes outputs from the simulation core before displaying them as a result. In this later stage, a series of performance indicators are calculated and an analytical hierarchical process (AHP) is performed to rank the results based on the user's prioritization weighting for each key performance indicator. As the main outcome of this contribution, the benefits of implementing this optimizer are evaluated in increasing the efficiency of the rest of the components of the tool and, consequently, of the overall calculation process.This study has been developed within the HEAT4COOL research project. This project has received funding from the European Union’s Horizon 2020 Research and Innovation Programme under grant agreement No 723925. This document reflects only the authors’ view and the Commission is not responsible for any use that may be made of the information it contains. The work has also been supported by the Swiss State Secretariat for Education, Research and Innovation (SERI) under Contract No. 16.0082
Characterization of the Recharge Area of the Water Collection of the Puyo River
El agua de lluvia, otras precipitaciones y la escorrentía superficial pueden reabastecer los acuíferos subterráneos en las zonas de recarga hídrica, la problemática radica cuando estas zonas de recarga presentan un ecosistema que no cumple con las condiciones mínimas de para que sean procesadas para consumo humano. El objetivo principal fue analizar la caracterización de la zona de recarga de la captación de agua del río Puyo. Mediante una metodología mixta, se realizó muestreos de agua y suelo para analizar las propiedades fisicoquímicas, así, utilizando pruebas de infiltración y compactación, se determinaron las características de la cuenca hidrográfica en estudio con ayuda de los programas Excel y Arcmap. Los resultados ms relevantes de esta investigación fueron que la cuenca tenía extensión de 4.6 km, su densidad de corriente obtuvo un valor de 25.11 km/km2 y el tiempo de concentración fue de 71 min; en la infiltración la velocidad máxima fue de 1cm/minuto en el tiempo de 20 minutos, el tipo de suelo encontrado fue Franco arcilloso arenoso y el caudal del punto de río de la toma de muestra fue de 0.370m3/s, las coliformes totales en promedio (4075 NMP) superaron los LMP; la infiltración acumulada fue de 47mm, la velocidad de infiltración promedio fue de 0.32cm/min, el carbono orgánico fue de 5.04% y la MO de 8.68%. En conclusión, la caracterización de la zona de recarga de la captación de agua del río Puyo logró determinar que los parámetros de pH y Turbidez estuvieron dentro de los LMP, mientras que la DBO lo superó por décimas, no obstante, los promedios de análisis de coliformes superaron doblemente los LMP, considerándolo un agua contaminada por actividades antropogénicas.Rainwater, other precipitation, and surface runoff can replenish groundwater aquifers in water recharge zones. The main objective was to analyze the characterization of the recharge zone of the Puyo river water intake. A qualitative-quantitative (mixed) methodology was used, water and soil sampling was carried out to analyze the physicochemical properties, likewise using infiltration and compaction tests, the characteristics of the hydrographic basin under study were determined with the help of Excel and Arcmap programs. The most relevant results of this investigation were that the basin had an extension of 4.6 km, its current density obtained a value of 25.11 km/km2 and the concentration time was 71 min; In the infiltration the maximum speed was 1cm/minute in the time of 20 minutes, the type of soil found was sandy clayey loam and the flow of the river point of the sampling was 0.370m3/s, the total coliforms in average (4075 MPN) exceeded the LMP; the accumulated infiltration was 47mm, the average infiltration speed was 0.32cm/min, while the organic carbon was 5.04% and the MO was 8.68%. In conclusion, the characterization of the recharge zone of the Puyo river water intake was able to determine that the pH and Turbidity parameters were within the LMP, while the BOD exceeded it by tenths, however, the analysis averages of coliforms doubled the LMP, considering it a water contaminated by anthropogenic activities
Modelación matemática de concentraciones de compuestos fenólicos en Hibiscus sabdariffa mediante el polinomio de Lagrange. Un análisis comparativo con datos experimentales
Mathematical modeling constitutes a field of research of great relevance in contemporary science. The objective of the present study was to develop a mathematical model based on the Lagrange polynomial to describe the variation of the concentrations of phenolic compounds in Hibiscus sabdariffa. Ultrasound-assisted extraction was applied to obtain aqueous extracts of hibiscus flowers, and the content of phenolic compounds was determined by the Folin-Ciucalteu method; these results were used to determine the Lagrange polynomial coefficients. The mathematical model was validated by comparing experimental and predicted data, and the Pearson correlation coefficient (r) was calculated to determine the strength of the relationship between the laboratory results and those predicted by the mathematical model. The mathematical model obtained was of grade 6 and the Pearson correlation coefficient was 0.999, which indicated the high capacity of the model to cover the entire range of the experimental data. The present study highlights the crucial relevance of mathematical models in the predictive capacity of experimental data, even in contexts where the factors have not been studied.La modelación matemática constituye un campo de investigación de gran relevancia en la ciencia contemporánea. El objetivo del presente estudio fue desarrollar un modelo matemático basado en el polinomio de Lagrange para describir la variación de las concentraciones de compuestos fenólicos en Hibiscus sabdariffa. Se aplicó la extracción asistida por ultrasonido para obtener extractos acuosos de flores de jamaica, y el contenido de compuestos fenólicos se determinó mediante el método de Folin-Ciucalteu, estos resultados se utilizaron para determinar los coeficientes del polinomio de Lagrange. El modelo matemático fue validado mediante la comparación de datos experimentales y predichos, además se calculó el coeficiente de correlación de Pearson (r) para determinar la fuerza de la relación entre los resultados de laboratorio y los predichos por el modelo matemático. El modelo matemático obtenido fue de grado 6 y el coeficiente de correlación de Pearson fue de 0,999 lo cual indicó la alta capacidad del modelo para cubrir todo el intervalo de los datos experimentales. El presente estudio subraya la relevancia crucial de los modelos matemáticos en la capacidad predictiva de datos experimentales, incluso en contextos donde los factores no han sido estudiados
Exploración comparativa de los métodos numéricos de Newton-Raphson y bisección para la resolución de ecuaciones no lineales
Solving nonlinear equations is crucial in various scientific and engineering fields. From determining the roots of algebraic equations to solving systems of differential equations, obtaining accurate and efficient numerical solutions is essential for modeling and analyzing a wide variety of natural phenomena. The objective of this article was to perform a comparative exploration of the Newton-Raphson and bisection numerical methods for solving nonlinear equations. The solution of three problems was analyzed including polynomial, exponential and trigonometric equations. The results obtained by the two methods were compared and discussed according to the precision and speed of convergence. It was concluded that the combination of both methods allowed optimal convergence, taking advantage of the speed of convergence and precision of the Newton-Raphson method and the robustness of the bisection method. This synergy provided an effective and efficient solution to a wide range of problems in engineering, science and applied mathematics, improving the resolution of nonlinear equations based on the specific characteristics of the problem and the requirements for precision and efficiency.Resumen
La resolución de ecuaciones no lineales es crucial en diversos campos científicos y de ingeniería. Desde determinar las raíces de ecuaciones algebraicas hasta resolver sistemas de ecuaciones diferenciales, obtener soluciones numéricas precisas y eficientes es esencial para modelar y analizar una amplia variedad de fenómenos naturales. El objetivo de este artículo fue realizar una exploración comparativa de los métodos numéricos de Newton-Raphson y bisección para la resolución de ecuaciones no lineales. Se analizó la solución de tres problemas incluyendo ecuaciones polinómicas, exponenciales y trigonométricas. Los resultados obtenidos por los dos métodos fueron comparados y discutidos según la precisión y velocidad de convergencia. Se concluyó que la combinación de ambos métodos permitió una convergencia óptima, aprovechando la velocidad de convergencia y precisión del método de Newton-Raphson y la robustez del método de bisección. Esta sinergia proporcionó una solución efectiva y eficiente para una amplia gama de problemas en ingeniería, ciencias y matemáticas aplicadas, mejorando la resolución de ecuaciones no lineales en función de las características específicas del problema y los requisitos de precisión y eficiencia.
 
Documentary review of wind energy for the generation of electrical energy in Ecuador
La presente investigación estudia las nuevas fuentes de energía renovables aplicables en el País como es la energía eólica, pues existen escasos estudios sobre el tema, que sustente por medio de una investigación científica tecnológica todas las etapas de la generación, acumulación y distribución. Objetivo. Revisar de forma documental la energía eólica para la generación de energía eléctrica en el Ecuador. Metodología. El método aplicado fue con un enfoque cuantitativo con alcance descriptivo, exploratorio y documental. Resultados. En los resultados obtenidos de la investigación documental se revisaron las tasas de producción de energía eólica que se dan en las diferentes plantas de producción del País en el cantón San Cristóbal en la central “Eólico San Cristóbal” se tiene 2,4 MW y en el cantón Baltra en la central “Baltra Eólico” se cuenta con una generación de 2,25 MW; posteriormente, en la provincia de Loja en la “Central Villonaco” se genera 16,50 MW, la generación eléctrica bruta a nivel nacional para el año 2021 es de 32.206,88 GWh. Conclusión. Se concluyo que el Ecuador posee las condiciones adecuadas para incrementar no únicamente su capacidad sino las plantas que posee; siendo este estudio un aporte al análisis del contexto de su desarrollo dentro del país.The present investigation studies the new renewable energy sources applicable in the country, such as wind energy, since there are few studies on the subject, which support all the stages of generation, accumulation and distribution through technological scientific research. Goal. Documentary review of wind energy for the generation of electrical energy in Ecuador. Methodology. The method applied was with a quantitative approach with a descriptive, exploratory and documentary scope. Results. In the results obtained from the documentary research, the wind energy production rates that occur in the different production plants of the country in the San Cristóbal canton were reviewed in the "Eolic San Cristóbal" power plant, it has 2.4 MW and in the Baltra canton in the "Baltra Eólico" plant has a generation of 2.25 MW; subsequently, in the province of Loja in the "Villonaco Power Plant" 16.50 MW is generated, the gross electricity generation at the national level for the year 2021 is 32,206.88 GWh. Conclusion. It was concluded that Ecuador has adequate conditions to increase not only its capacity but also the plants it has; this study being a contribution to the analysis of the context of its development within the country
Fenómenos Hidrodinámicos en una Turbina de Vórtice de Eje Vertical
The present work aims to generate a simulation designed in a safe way to generate a sustainable hydraulic system coupled to energy study needs, which collaborates with less costs and more benefits. Based on simulations with the scale model using the ANSYS tool, which aims to find the efficiency at the time of running this simulation at full scale. Mainly the motivations of the work based on new methods of obtaining energy for the conservation of the environment. This is how the idea of designing and simulating a new gravitational vortex turbine system, with geometries according to what has been found in the literature and in previous studies, is materialized. In this way, we proceed to design and simulate a turbine device composed of a vortex impeller that can resist erosion and sediments and that allows the development of a gravitational vortex with a considerable hydraulic power. Once the geometry of the turbine is defined, a modeling is made in ANSYS software, in order to know the behavior of the vortex, for the definition of the geometric configuration of which will also operate under the concept of "drag".El presente trabajo tiene como objetivo desarrollar un simulación diseñado de manera segura al generar un sistema hidráulico sostenible acoplándose a necesidades de estudio energético, el cual colabore con menos costos y más beneficios. Basado en simulaciones con el modelo de escala mediante la herramienta de ANSYS, el cual tiene como objetivo encontrar la eficiencia al momento de ejecutar esta simulación a escala real. Principalmente las motivaciones del trabajo se fundamentan en nuevos métodos de obtención de energía para la conservación del medio ambiente. Es así como se materializa la idea de diseñar y simular un nuevo sistema de turbinas de vórtices gravitacionales, con geometrías según lo encontrado en la literatura, y en estudios anteriores. De esta forma se procede a diseñar y simular un dispositivo de turbina compuesto por un impulsor de vórtice que pueda resistir la erosión y sedimentos y que permita el desarrollo de un vórtice gravitacional con una potencia hidráulica considerable. Una vez definida la geometría de la turbina se procede a realizar un modelado en el software ANSYS, con el fin de conocer el comportamiento del vórtice, para la definición de la configuración geométrica de los cuales además funcionarán bajo el concepto de "arrastre"
Oral administration of Sauce llorón extract to growing lambs to control gastrointestinal nematodes and Moniezia spp
The TMR used was the same that was previously fed to lambs of the experiment done at the same farm by Salem et al.[18]. Lambs were fed the same TMR with the addition of 0, 20, 40 and 60 mL SB extract/lamb/day for Control (SB0), SB20, SB40 and SB60, respectively. Extract was orally administered daily at 7:00 h before morning feeding to each lamb for 45 days of the experimental period. Lambs were fed at 7:00, 13:00 and 17:00 h with a TMR that was formulated to meet all of their nutrient requirements[19]. Feed and water intake was recorded daily during the experimental period.Objective: To explore anthelmintic effects of oral administration of aqueous extract of Sauce llor ´on (Salix babylonica; SB) against gastrointestinal nematodes and Moniezia spp. Methods: Sixteen Pelibuey male lambs of 3–4 months of age and (23.7 ± 3.3) kg body weight were used in a completely randomized design to be fed a total mixed ration (Control; SB0), or Control plus SB extract using 20 (SB20), 40 (SB40) and 60 (SB60) mL/lamb/day for 45 days. Lambs had a natural gastrointestinal nematodes and Moniezia spp. infection and had never been treated with chemical anthelmintic drugs. Individual faecal samples were collected for ova counting using McMaster procedure after 0, 7, 14, 21, 30 and 45 days post extract administration. Results: No extract dose × day interactions for both gastrointestinal nematodes and Moniezia spp. egg count were found. Administration of SB extract had a higher effect (quadratic effect, P = 0.006 4) at dose of 20 mL SB/lamb/day for gastrointestinal nematode eggs during the first 21 days; however, the dose of SB40 tended (linear effect, P = 0.089 7) to be more effective than the others for Moniezia spp. egg during the first 7 days. Sampling day had a linear (P = 0.043 6) effect on Moniezia spp. egg count. Conclusions: The aqueous extract of SB could be more effective against nematodes at 20 and at 40 mL/lamb/day for Moniezia spp. The use of the SB extract could represent a promising alternative to synthetic anthelmintics for the treatment of gastrointestinal nematodes and Moniezia spp. in small ruminants from organic and conventional production system
Evaluación de la contaminación acústica en el terminal terrestre del cantón Morona, ciudad Macas mediante la identificación de niveles de presión sonora
Se evaluó la contaminación acústica del Terminal Terrestre Dr. Roberto Villarreal V. mediante los niveles de presión sonora que se genera, teniendo como objetivo conocer el valor de ruido ambiental existente. Se realizó un levantamiento de información en el área de estudio, identificando las zonas sensibles a la contaminación acústica, precisando nueve puntos de monitoreo; para la realización de la cartografía temática (mapa de ruido) se utilizó la herramienta informática ArcGIS aplicando la técnica de Distancia Inversa Ponderada (IDW). Para la obtención de datos se utilizó un sonómetro integrador Tipo II, con ponderación frecuencial A y modo de respuesta lenta (Slow), en tres periodos de tomas (mañana, tarde y noche) mediante la metodología de 15 segundos reportando 5 muestras de 15s durante 10 minutos por cada punto obteniendo 405 muestras diarias. Los resultados se obtuvieron aplicando la metodología dada en la normativa Acuerdo Ministerial 097 Anexo 5 del Ministerio de Ambiente, mostrando que en los tres periodos establecidos los puntos P3 ubicado en el área de Embarque Intercantonal con 66.99 dB, P4 ubicado en el área de confitería con 68.00 dB, P7 ubicado en la llegada de buses con 68.52 dB y P8 ubicado en el área de Embarque Interprovincial con 67.64 dB, presentaron mayor nivel de ruido, superando el límite permisible de 55 dB. Determinando que el ruido que se produce en el terminal es influenciado por el ruido externo como las actividades económicas y tráfico vehicular liviano y pesado que se desarrollan alrededor de las instalaciones de área de estudio, generando un cambio de nivel de ruido en el terminal
- …