50 research outputs found

    Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures

    Get PDF
    Purpose: The purpose of this study was to compare femoral head placement, rates of reoperation and cephalic implant cut-out of a screw versus a blade for patients over age 60 with low energy trochanteric fractures (AO/OTA 31-A1, A2, and A3) treated either with sliding hip screw or cephalomedullary nail. Methods: After surgeon selection of either hip screw or nail, hip screw patients were randomised to either a DHS (dynamic hip system screw) or DHS blade (dynamic hip system blade), while nail patients were randomised to either a Gamma3 Trochanteric Nail or a PFNA (proximal femoral nail antirotation). This resulted in a screw group (DHS and Gamma nail), and a blade group (DHS blade and PFNA). Outcome measures included tip-apex distance and zone location of the cephalic implant, as well as reoperation and implant cut-out within the first postoperative year. Results: A total of 335 patients were randomised, 172 to a screw and 163 to a blade. There was no significant difference concerning mean tip-apex distance, percentage of patients with a tip-apex distance >25mm, and patients with a centre-centre position of the cephalic implant. There were 137 patients in the screw group and 132 in the blade group available for follow-up. They did not differ regarding rates of reoperation or cut-out (screw group = 2.9%; blade group = 1.5%). Conclusions: Both a screw and a blade performed equally well in terms of implant placement in the femoral head and outcom

    Upper extremity fractures in the elderly: consequences on utilization of rehabilitation care

    Get PDF
    Background and aims: While hip fractures represent the most dramatic consequence of osteoporosis, fractures of the humerus, forearm and wrist account for one-third of the total incidence of fractures due to osteoporosis in the older population. The aim of this retrospective cohort study was to evaluate rehabilitation care utilization and associated factors in elderly individuals with upper limb fracture. Methods: Over two years, 667 patients 65 years of age or older were studied, who presented to the emergency department either from their private homes or nursing homes with an upper extremity fracture. The following outcome variables were collected: gender; age; residence; location of fracture; treatment; discharge destination; length of hospitalization; length of stay in a rehabilitation facility; and ultimate place of habitation after the event. Results: The most frequent sites of fracture were distal radius (37.2%) and proximal humerus (29.1%). Two-thirds of the patients were treated non-operatively. Inpatient rehabilitation care was necessary for 248 patients (37.2%; length of stay, 46 days). Factors associated with increased care included older age (≄80 years), coming from private home, sustaining two fractures, fractures of the humerus, and operative treatment. Six percent of the patients required permanent nursing home care. Conclusions: Upper extremity fractures in older people often require prolonged hospitalization and therefore account for considerable health care costs. Reasons are more related to advanced age and living conditions than to particular injury or treatmen

    Risk factors for post-traumatic osteoarthritis of the ankle: an eighteen year follow-up study

    Get PDF
    Purpose: Long-term studies evaluating risk factors for development of ankle osteoarthritis (OA) following malleolar fractures are sparse. Methods: We conducted a retrospective cohort study including consecutive patients treated by open reduction and internal fixation for malleolar fracture between January 1988 and December 1997. Perioperative information was obtained retrospectively. Patients were evaluated clinically and radiographically 12-22years postoperatively. Radiographic ankle OA was determined on standardised radiographs using the Kellgren and Lawrence scale (grade 3-4 = advanced OA). Uni- and multivariate regression analyses were performed to determine risk factors for OA. Results: During the inclusion period, 373 fractures (372 patients; 9% Weber A, 58% Weber B, 33% Weber C) were operated upon. The mean age at operation was 42.9years. There were 102 patients seen at follow-up (mean follow-up 17.9years). Those not available did not differ in demographics and fracture type from those seen. Advanced radiographic OA was present in 37 patients (36.3%). Significant risk factors were: Weber C fracture, associated medial malleolar fracture, fracture-dislocation, increasing body mass index, age 30years or more and length of time since surgery. Conclusions: Advanced radiographic OA was common 12-22years after malleolar fracture. The probability of developing post-traumatic OA among patients having three or more risk factors was 60-70

    Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws

    Get PDF
    Total hip arthroplasty (THA) with well designed cementless acetabular implants has shown excellent results. The purpose of this study was to assess our clinical and radiological outcomes using an uncemented cup. We conducted a prospective cohort study including all consecutive primary THAs performed with the Morscher press-fit cup, an uncemented non-modular acetabular component, between March 1996 and December 1998. Patients were evaluated at tenyears with clinical and radiological follow-up, patient satisfaction and questionnaire assessment using the Harris hip score (HHS), Merle d'Aubigné and Postel score, the UCLA score, the 12-item short-form health survey (SF-12) and a visual analog scale. Five hundred sixty-one THAs were performed in 518 patients. At 120months (± 7.3months), 303 patients with 335 THAs were still available for follow-up. None of the patients had required cup revision for aseptic loosening. At tenyears, the cup survivorship was 98.8% (95% CI 97.4-99.5) with cup revision for any cause as an endpoint. No radiolucencies were seen around the cups, but osteolytic defects involved 21 stems (8.3%). Mean total linear polyethylene wear was 0.9mm. The Morscher acetabular replacement cup provides excellent results at tenyears. There were no revisions for aseptic loosening of the cup, and no osteolytic defects were found around the cup. Patient satisfaction was high and the clinical results were very goo

    Adipokines correlate with pain in lower limb osteoarthritis: different associations in hip and knee

    Get PDF
    Purpose: Our aim was to investigate whether serum and synovial-fluid (SF) concentrations of interleukin-6 (IL-6), leptin, adiponectin, resistin or visfatin are associated with joint pain in hip and knee in end-stage osteoarthritis (OA). Methods: A cross-sectional study assessing patients with hip and knee OA undergoing total joint arthroplasty between January and December 2010 was conducted at a large university hospital. Serum and SF cytokine and adipokine concentrations were determined in samples obtained on the day of surgery. The main outcome was pain severity measured pre-operatively using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and visual analogue scale (VAS) pain scores. Results: A total of 206 patients were involved (112 with hip and 94 with knee OA). Median age was 72years [interquartile range (IQR) 66-79], 59% were women. All adipokine levels were significantly higher in the SF of hip joints than in that of knee joints, except for leptin, which tended to be higher in the knee. In both hip and knee OA, median serum concentrations of leptin, adiponectin, resistin and visfatin exceeded those in SF, whereas for IL-6, median concentrations were much higher in SF than in serum. In hip OA, worse pain was significantly associated with high SF concentrations of IL-6, visfatin and leptin; in knee OA, it was associated with high SF leptin and low SF adiponectin concentrations and a low adiponectin-leptin ratio. Conclusion: Our findings support a connection between intra-articular concentrations of several adipokines and severity of preoperative OA pain. However, the specific adipokines differed by joints: in hip OA, pain was associated with IL-6 and visfatin and in knee OA with adiponectin; leptin played a role in both hip and knee OA

    Do synovial leptin levels correlate with pain in end stage arthritis?

    Get PDF
    Purpose: We evaluated whether synovial fluid (SF) leptin concentrations correlate with pain severity in patients with hip or knee endstage osteoarthritis (OA) and whether they mediate the association between increased joint pain and (1) female gender and (2) obesity. Methods: We conducted a cross-sectional study including patients with primary hip and knee OA undergoing joint replacement between January and December 2010. SF leptin concentrations obtained on the day of surgery were assessed. Main outcome was pain severity measured pre-operatively using WOMAC and VAS pain scales. Results: A total of 219 patients were included, 123 hip and 96 knee arthroplasties. Mean age was 72years, 59% were women. Mean SF leptin levels were 22.9 (±25.6) ng/ml in women and 5.4 (±5.9) ng/ml in men. Levels >19.6ng/ml (highest quartile) were significantly associated with increased pain on both WOMAC (mean difference −9.6, 95% CI −15.1 to −4.0) and VAS scale (mean difference 0.8, 95% CI 0.2-1.3). Associations remained unchanged after adjusting for age, co-morbidities, contra-lateral arthritic joint, OA site, and disability. The associations observed between increased pain and female gender or obesity were substantially reduced after adjusting for SF leptin. Conclusion: Joint pain is associated with SF leptin concentrations. Increased pre-operative pain observed in women and obese may be related to high intra-articular leptin level

    Introduction of innovations in joint arthroplasty: Recommendations from the 'EFORT implant and patient safety initiative'

    Get PDF
    With the implementation of the new MDR 2017/745 by the European Parliament, more robust clinical and pre-clinical data will be required due to a more stringent approval process. The EFORT Implant and Patient Safety Initiative WG1 ‘Introduction of Innovation’, combined knowledge of orthopaedic surgeons, research institutes, orthopaedic device manufacturers, patient representatives and regulatory authorities to develop a comprehensive set of recommendations for the introduction of innovations in joint arthroplasty within the boundaries of MDR 2017/745. Recommendations have been developed to address key questions about pre-clinical and clinical requirements for the introduction of new implants and implant-related instrumentation with the participation of a steering group, invited by the EFORT Board in dialogue with representatives from European National Societies and Speciality Societies. Different degrees of novelty and innovation were described and agreed on in relation to when surgeons can start, using implants and implant-related instrumentation routinely. Before any clinical phase of a new implant, following the pre-market clinical investigation or the equivalent device PMCF pathway, it is a common understanding that all appropriate pre-clinical testing (regulatory mandatory and evident state of the art) – which has to be considered for a specific device – has been successfully completed. Once manufacturers receive the CE mark for a medical device, it can be used in patients routinely when a clinical investigation has been conducted to demonstrate the conformity of devices according to MDR Article 62 or full equivalence for the technical, biological and clinical characteristics has been demonstrated (MDR, Annex XIV, Part A, 3.) and a PMCF study has been initiated

    International variation in distribution of ASA class in patients undergoing total hip arthroplasty and its influence on mortality: data from an international consortium of arthroplasty registries

    Get PDF
    Background and purpose - A challenge comparing outcomes from total hip arthroplasty between countries is variation in preoperative characteristics, particularly comorbidity. Therefore, we investigated between-country variation in comorbidity in patients based on ASA class distribution, and determined any variation of ASA class to mortality risk between countries.Patients and methods - All arthroplasty registries collecting ASA class and mortality data in patients with elective primary THAs performed 2012-2016 were identified. Survival analyses of the influence of ASA class on 1-year mortality were performed by individual registries, followed by meta-analysis of aggregated data.Results - 6 national registries and 1 US healthcare organization registry with 418,916 THAs were included. There was substantial variation in the proportion of ASA class III/IV, ranging from 14% in the Netherlands to 39% in Finland. Overall, 1-year mortality was 0.93% (95% CI 0.87-1.01) and increased from 0.2% in ASA class I to 8.9% in class IV. The association between ASA class and mortality measured by hazard ratios (HR) was strong in all registries even after adjustment for age and sex, which reduced them by half in all registries. Combined adjusted HRs were 2.0, 6.1, and 22 for ASA class II-IV vs. I, respectively. Associations were moderately heterogeneous across registries.Interpretation - We observed large variation in ASA class distribution between registries, possibly explained by differences in background morbidity and/or international variation in access to surgery. The similar, strong mortality trends by ASA class between countries enhance the relevance of its use as an indicator of comorbidity in international registry studies.</p
    corecore