59 research outputs found

    New mechanisms to explain the effects of added lactose fines on the dispersion performance of adhesive mixtures for inhalation

    Get PDF
    Fine excipient particles or 'fines' have been shown to improve the dispersion performance of carrier-based formulations for dry powder inhalation. Mechanistic formulation studies have focussed mainly on explaining this positive effect. Previous studies have shown that higher drug contents may cause a decrease in dispersion performance, and there is no reason why this should not be true for fines with a similar shape, size and cohesiveness as drug particles. Therefore, the effects on drug detachment of 'fine lactose fines' (FLF, X50 = 1.95 µm) with a similar size and shape as micronised budesonide were studied and compared to those of 'coarse lactose fines' (CLF, X50 = 3.94 µm). Furthermore, interactions with the inhalation flow rate, the drug content and the mixing order were taken into account. The observed effects of FLF are comparable to drug content effects in that the detached drug fraction was decreased at low drug content and low flow rates but increased at higher flow rates. At high drug content the effects of added FLF were negligible. In contrast, CLF resulted in higher detached drug fractions at all flow rates and drug contents. The results from this study suggest that the effects of fines may be explained by two new mechanisms in addition to those previously proposed. Firstly, fines below a certain size may increase the effectiveness of press-on forces or cause the formation of strongly coherent fine particle networks on the carrier surface containing the drug particles. Secondly, when coarse enough, fines may prevent the formation of, or disrupt such fine particle networks, possibly through a lowering of their tensile strength. It is recommended that future mechanistic studies are based on the recognition that added fines may have any effect on dispersion performance, which is determined by the formulation and dispersion conditions

    Realising the potential of various inhaled airway challenge agents through improved delivery to the lungs

    Get PDF
    Inhaled airway challenges provoke bronchoconstriction in susceptible subjects and are a pivotal tool in the diagnosis and monitoring of obstructive lung diseases, both in the clinic and in the development of new respiratory medicines. This article reviews the main challenge agents that are in use today (methacholine, mannitol, adenosine, allergens, endotoxin) and emphasises the importance of controlling how these agents are administered. There is a danger that the optimal value of these challenge agents may not be realised due to suboptimal inhaled delivery; thus considerations for effective and reproducible challenge delivery are provided. This article seeks to increase awareness of the importance of precise delivery of inhaled agents used to challenge the airways for diagnosis and research, and is intended as a stepping stone towards much-needed standardisation and harmonisation in the administration of inhaled airway challenge agents

    Prerequisites for a dry powder inhaler for children with cystic fibrosis

    Get PDF
    Correct inhalation technique is essential for effective use of dry powder inhalers (DPIs), as their effectiveness largely depends on the patient's inhalation manoeuvre. Children are an especially challenging target population for DPI development due to the large variability in understanding and inspiratory capacities. We previously performed a study in which we determined the prerequisites for a paediatric DPI in a mostly healthy paediatric population, for which we used an empty test inhaler with variable internal airflow resistance and mouthpiece. In the current study we investigated what specifications are required for a DPI for children with cystic fibrosis (CF), for which we expanded on our previous findings. We recorded flow profiles of 35 children with CF (aged 4.7-14.7 years) at three airflow resistances (0.031-0.045 kPa0.5.min.L-1) from which various inspiratory parameters were computed. Obstructions in the mouth during inhalation were recorded with a sinuscope. All children were able to perform a correct inhalation manoeuvre, although video analysis showed that children did not place the inhaler correctly in the mouth in 17% of the cases. No effect was found of medium to high airflow resistance on total inhaled volume, which implies that the whole resistance range tested is suitable for children with CF aged 4-14 years. No effect could be established of either mouthpiece design or airflow resistance on the occurrence of obstructions in the mouth cavity. This study confirms our previous conclusion that the development of DPIs specifically for children is highly desired. Such a paediatric DPI should function well at 0.5 L inhaled volume and a peak inspiratory flow rate of 20 to 30 L/min, depending on the internal airflow resistance. This resistance can be increased up to 0.045 kPa0.5.min.L-1 (medium-high) to reduce oropharyngeal deposition. A higher resistance may be less favourable due to its compromising effect on PIF and thereby on the energy available for powder dispersion

    Targeting the small airways with dry powder adenosine:A challenging concept

    Get PDF
    Background: Small-particle inhaled corticosteroids (ICS) provide a higher small airway deposition than large-particle ICS. However, we are still not able to identify asthma patients who will profit most from small-particle treatment. Objective: We aimed to identify these patients by selectively challenging the small and large airways. We hypothesized that the airways could be challenged selectively using small- and large-particle adenosine, both inhaled at a high and a low flow rate. Design: In this cross-over study 11 asthma subjects performed four dry powder adenosine tests, with either small (MMAD 2.7 µm) or large (MMAD 6.0 µm) particles, inhaled once with a low flow rate (30 l min(-1)) and once with a high flow rate (60 l min(-1)). Spirometry and impulse oscillometry were performed after every bronchoprovocation step. We assumed that FEV1 reflects the large airways, and FEF25-75%, R5-R20 and X5 reflect the small airways. Results: The four adenosine tests were not significantly different with respect to the threshold values of FEV1 (p = 0.12), FEF25-75% (p = 0.37), R5-R20 (p = 0.60) or X5 (p = 0.46). Both small- and large-particle adenosine induced a response in the small airways in the majority of the tests. Conclusions: In contrast to our hypothesis, all four adenosine tests provoked a response in the small airways and we could not identify different large- or small-airway responders. Interestingly, even the test with large particles and a high flow rate induced a small-airway response, suggesting that selective challenging of the small airways is not necessary. Future studies should investigate the relation between particle deposition and the site of an airway response

    Predictors of clinical response to extrafine and non-extrafine particle inhaled corticosteroids in smokers and ex-smokers with asthma

    Get PDF
    We performed a post-hoc analysis of the OLiVIA-study investigating whether current and ex-smoking asthmatics with small airways dysfunction (SAD) show a better response in airway hyperresponsiveness (AHR) to small particle adenosine after treatment with extrafine compared to non-extrafine particle inhaled corticosteroids (ICS), and to investigate which clinical parameters predict a favorable response to both treatments. We show that smoking and ex-smoking asthmatics with and without SAD have a similar treatment response with either extrafine or non-extrafine particle ICS. We also found that lower blood neutrophils are associated with a smaller ICS-response in smokers and ex-smokers with asthma, independent from the level of blood eosinophils

    Associations of AMP and adenosine induced dyspnea sensation to large and small airways dysfunction in asthma

    Get PDF
    Abstract Background Bronchial provocation is often used to confirm asthma. Dyspnea sensation, however, associates poorly with the evoked drop in FEV1. Provocation tests only use the large airways parameter FEV1, although dyspnea is associated with both large- and small airways dysfunction. Aim of this study was to explore if adenosine 5′-monophosphate (AMP) and adenosine evoke an equal dyspnea sensation and if dyspnea associates better with large or small airways dysfunction. Methods We targeted large airways with AMP and small airways with dry powder adenosine in 59 asthmatic (ex)-smokers with ≥5 packyears, 14 ± 7 days apart. All subjects performed spirometry, impulse oscillometry (IOS), and Borg dyspnea score. In 36 subjects multiple breath nitrogen washout (MBNW) was additionally performed. We analyzed the association of the change (Δ) in Borg score with the change in large and small airways parameters, using univariate and multivariate linear regression analyses. MBNW was analyzed separately. Results Provocation with AMP and adenosine evoked similar levels of dyspnea. ΔFEV1 was not significantly associated with ΔBorg after either AMP or adenosine provocation, in both univariate and multivariate analyses. In multivariate linear regression, a decrease in FEF25–75 during adenosine provocation was independently associated with an increase in Borg. In the multivariate analyses for AMP provocation, no significant associations were found between ΔBorg and any large or small airways parameters. Conclusion AMP and adenosine induce equally severe dyspnea sensations. Our results suggest that dyspnea induced with dry powder adenosine is related to small airways involvement, while neither large nor small airways dysfunction was associated with AMP-induced dyspnea. Trail registration NCT01741285 at www.clinicaltrials.gov, first registered Dec 4th, 2012

    COVID-19 in health-care workers in three hospitals in the south of the Netherlands:A cross-sectional study

    Get PDF
    Background: 10 days after the first reported case of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in the Netherlands (on Feb 27, 2020), 55 (4%) of 1497 health-care workers in nine hospitals located in the south of the Netherlands had tested positive for SARS-CoV-2 RNA. We aimed to gain insight in possible sources of infection in health-care workers. Methods: We did a cross-sectional study at three of the nine hospitals located in the south of the Netherlands. We screened health-care workers at the participating hospitals for SARS-CoV-2 infection, based on clinical symptoms (fever or mild respiratory symptoms) in the 10 days before screening. We obtained epidemiological data through structured interviews with health-care workers and combined this information with data from whole-genome sequencing of SARS-CoV-2 in clinical samples taken from health-care workers and patients. We did an in-depth analysis of sources and modes of transmission of SARS-CoV-2 in health-care workers and patients. Findings: Between March 2 and March 12, 2020, 1796 (15%) of 12 022 health-care workers were screened, of whom 96 (5%) tested positive for SARS-CoV-2. We obtained complete and near-complete genome sequences from 50 health-care workers and ten patients. Most sequences were grouped in three clusters, with two clusters showing local circulation within the region. The noted patterns were consistent with multiple introductions into the hospitals through community-acquired infections and local amplification in the community. Interpretation: Although direct transmission in the hospitals cannot be ruled out, our data do not support widespread nosocomial transmission as the source of infection in patients or health-care workers. Funding: EU Horizon 2020 (RECoVer, VEO, and the European Joint Programme One Health METASTAVA), and the National Institute of Allergy and Infectious Diseases, National Institutes of Health

    COVID-19 in health-care workers in three hospitals in the south of the Netherlands: a cross-sectional study

    Get PDF
    Background: 10 days after the first reported case of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in the Netherlands (on Feb 27, 2020), 55 (4%) of 1497 health-care workers in nine hospitals located in the south of the Netherlands had tested positive for SARS-CoV-2 RNA. We aimed to gain insight in possible sources of infection in health-care workers. Methods: We did a cross-sectional study at three of the nine hospitals located in the south of the Netherlands. We screened health-care workers at the participating hospitals for SARS-CoV-2 infection, based on clinical symptoms (fever or mild respiratory symptoms) in the 10 days before screening. We obtained epidemiological data through structured interviews with health-care workers and combined this information with data from whole-genome sequencing of SARS-CoV-2 in clinical samples taken from health-care workers and patients. We did an in-depth analysis of sources and modes of transmission of SARS-CoV-2 in health-care workers and patients. Findings: Between March 2 and March 12, 2020, 1796 (15%) of 12 022 health-care workers were screened, of whom 96 (5%) tested positive for SARS-CoV-2. We obtained complete and near-complete genome sequences from 50 health-care workers and ten patients. Most sequences were grouped in three clusters, with two clusters showing local circulation within the region. The noted patterns were consistent with multiple introductions into the hospitals through community-acquired infections and local amplification in the community. Interpretation: Although direct transmission in the hospitals cannot be ruled out, our data do not support widespread nosocomial transmission as the source of infection in patients or health-care workers. Funding: EU Horizon 2020 (RECoVer, VEO, and the European Joint Programme One Health METASTAVA), and the National Institute of Allergy and Infectious Diseases, National Institutes of Health

    Challenging the two-minute tidal breathing challenge test

    No full text
    BACKGROUND: In the adenosine 5'-monophosphate (AMP) bronchial challenge test, AMP is usually administered according to dosing protocols for methacholine. We investigated whether the 2-min tidal breathing challenge test for methacholine is applicable to AMP. Parameters known to affect nebulizer output were studied. Our aim was to determine whether control of additional parameters is needed for currently standardized protocols. METHODS: The study was performed with the Sidestream nebulizer from the APS Pro Aerosol Provocation System (CareFusion Respiratory). The effects of AMP concentration, jet pressure, and suction flow rate on nebulizer output rate and aerosol droplet size distribution were determined. RESULTS: The volume median diameter for water increased from 5.10 μm to 8.49 μm when the jet pressure was reduced to obtain the prescribed output rate of 0.13 mL/min. The output rate was increased when a suction flow rate was used to remove the aerosol. Increasing the AMP concentration resulted in smaller droplets and a lower output rate when a suction flow was applied. CONCLUSIONS: The effects of AMP concentration on nebulizer performance may result in changes in the administered dose and site of deposition of AMP at dose escalation. All of the investigated parameters influence nebulizer performance, hence the outcome of a bronchial challenge test. Therefore, these parameters should not only be specified in challenge testing, but be actively controlled as well
    corecore