140 research outputs found

    Semi-automated and fully automated mammographic density measurement and breast cancer risk prediction

    Full text link
    The task of breast density quantification is becoming increasingly relevant due to its association with breast cancer risk. In this work, a semi-automated and a fully automated tools to assess breast density from full-field digitized mammograms are presented. The first tool is based on a supervised interactive thresholding procedure for segmenting dense from fatty tissue and is used with a twofold goal: for assessing mammographic density(MD) in a more objective and accurate way than via visual-based methods and for labeling the mammograms that are later employed to train the fully automated tool. Although most automated methods rely on supervised approaches based on a global labeling of the mammogram, the proposed method relies on pixel-level labeling, allowing better tissue classification and density measurement on a continuous scale. The fully automated method presented combines a classification scheme based on local features and thresholding operations that improve the performance of the classifier. A dataset of 655 mammograms was used to test the concordance of both approaches in measuring MD. Three expert radiologists measured MD in each of the mammograms using the semi-automated tool (DM-Scan). It was then measured by the fully automated system and the correlation between both methods was computed. The relation between MD and breast cancer was then analyzed using a case-control dataset consisting of 230 mammograms. The Intraclass Correlation Coefficient (ICC) was used to compute reliability among raters and between techniques. The results obtained showed an average ICC = 0.922 among raters when using the semi-automated tool, whilst the average correlation between the semi-automated and automated measures was ICC = 0.838. In the case-control study, the results obtained showed Odds Ratios (OR) of 1.38 and 1.50 per 10% increase in MD when using the semi-automated and fully automated approaches respectively. It can therefore be concluded that the automated and semi-automated MD assessments present a good correlation. Both the methods also found an association between MD and breast cancer risk, which warrants the proposed tools for breast cancer risk prediction and clinical decision making. A full version of the DM-Scan is freely available. (C) 2014 Elsevier Ireland Ltd. All rights reserved.This work was supported by research grants from Gent per Gent Fund (EDEMAC Project); Spain's Health Research Fund (Fondo de Investigacion Santiaria) (PI060386 & FIS PS09/00790); Spanish MICINN grants TIN2009-14205-C04-02 and Consolider-Ingenio 2010: MIPRCV (CSD2007-00018); Spanish Federation of Breast Cancer Patients (Federacion Espanola de Cancer de Mama) (FECMA 485 EPY 1170-10). The English revision of this paper was funded by the Universitat Politecnica de Valencia, Spain.Llobet Azpitarte, R.; Pollán, M.; Antón Guirao, J.; Miranda-García, J.; Casals El Busto, M.; Martinez Gomez, I.; Ruiz Perales, F.... (2014). Semi-automated and fully automated mammographic density measurement and breast cancer risk prediction. Computer Methods and Programs in Biomedicine. 116(2):105-115. https://doi.org/10.1016/j.cmpb.2014.01.021S105115116

    Magnetic resonance imaging of the knee in Norway 2002–2004 (national survey): rapid increase, older patients, large geographic differences

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Magnetic resonance imaging (MRI) of the knee is the second most common MRI examination in Norway after head/brain MRI. Little has been published internationally on trends in the use of knee MRI after 1999. This study aimed to describe levels and trends in ambulant knee MRI utilisation in Norway 2002–2004 in relation to type of radiology service, geographic regions, number of MRI-scanners, patient age and gender, and type of referring health care provider.</p> <p>Methods</p> <p>We analysed administrative data on all claims for reimbursement of ambulant knee MRI performed in Norway in 2002, 2003 and 2004 and noted nominal reimbursement. We also recorded the referring health care provider from clinical requests of ambulant knee MRI done consecutively during two months in 2004 at one private institute and three hospitals. Number of MRI-scanners was given by manufacturers and radiology services.</p> <p>Results</p> <p>In Norway, the rate of knee MRI claims for 2004 was 15.6 per 1000 persons. This rate was 74% higher in East than in North region (18.4 vs. 10.6), slightly higher for men than women (16.4 vs. 14.7) and highest for ages 50–59 years (29.0) and 60–69 years (21.2). Most claims (76% for 2004) came from private radiology services. In 2004, the referring health care provider was a general practitioner in 63% of claims (unspecified in 24%) and in 83.5% (394/472) of clinical requests. From 2002 to 2004, the rate of knee MRI claims increased 64%. In the age group 50 years or above the increase was 86%. Rate of MRI-scanners increased 43% to 21 scanners per million persons in 2004. Reimbursement for knee MRI claims (nominal value) increased 80% to 70 million Norwegian kroner in 2004.</p> <p>Conclusion</p> <p>Ambulant knee MRI utilisation in Norway increases rapidly especially for patients over 50, and shows large geographic differences. Evaluation of clinical outcomes of this activity is needed together with clinical guidelines for use of knee MRI.</p

    Prospective screening study of 0.5 Tesla dedicated magnetic resonance imaging for the detection of breast cancer in young, high-risk women

    Get PDF
    BACKGROUND: Evidence-based screening guidelines are needed for women under 40 with a family history of breast cancer, a BRCA1 or BRCA2 mutation, or other risk factors. An accurate assessment of breast cancer risk is required to balance the benefits and risks of surveillance, yet published studies have used narrow risk assessment schemata for enrollment. Breast density limits the sensitivity of film-screen mammography but is not thought to pose a limitation to MRI, however the utility of MRI surveillance has not been specifically examined before in women with dense breasts. Also, all MRI surveillance studies yet reported have used high strength magnets that may not be practical for dedicated imaging in many breast centers. Medium strength 0.5 Tesla MRI may provide an alternative economic option for surveillance. METHODS: We conducted a prospective, nonrandomized pilot study of 30 women age 25–49 years with dense breasts evaluating the addition of 0.5 Tesla MRI to conventional screening. All participants had a high quantitative breast cancer risk, defined as ≥ 3.5% over the next 5 years per the Gail or BRCAPRO models, and/or a known BRCA1 or BRCA2 germline mutation. RESULTS: The average age at enrollment was 41.4 years and the average 5-year risk was 4.8%. Twenty-two subjects had BIRADS category 1 or 2 breast MRIs (negative or probably benign), whereas no category 4 or 5 MRIs (possibly or probably malignant) were observed. Eight subjects had BIRADS 3 results, identifying lesions that were "probably benign", yet prompting further evaluation. One of these subjects was diagnosed with a stage T1aN0M0 invasive ductal carcinoma, and later determined to be a BRCA1 mutation carrier. CONCLUSION: Using medium-strength MRI we were able to detect 1 early breast tumor that was mammographically undetectable among 30 young high-risk women with dense breasts. These results support the concept that breast MRI can enhance surveillance for young high-risk women with dense breasts, and further suggest that a medium-strength instrument is sufficient for this application. For the first time, we demonstrate the use of quantitative breast cancer risk assessment via a combination of the Gail and BRCAPRO models for enrollment in a screening trial

    Medicolegal—Malpractice and Ethical Issues in Radiology

    No full text

    Breast MRI BI-RADS®: Second Edition Highlights

    No full text