2,125 research outputs found

    Ideal observer analysis for continuous tracking experiments

    Get PDF
    Continuous tracking is a newly developed technique that allows fast and efficient data acquisition by asking participants to “track” a stimulus varying in some property (usually position in space). Tracking is a promising paradigm for the investigation of dynamic features of perception and could be particularly well suited for testing ecologically relevant situations difficult to study with classical psychophysical paradigms. The high rate of data collection may be useful in studies on clinical populations and children, who are unable to undergo long testing sessions. In this study, we designed tracking experiments with two novel stimulus features, numerosity and size, proving the feasibility of the technique outside standard object tracking. We went on to develop an ideal observer model that characterizes the results in terms of efficiency of conversion of stimulus strength into responses, and identification of early and late noise sources. Our ideal observer closely modeled results from human participants, providing a generalized framework for the interpretation of tracking data. The proposed model allows to use the tracking paradigm in various perceptual domains, and to study the divergence of human participants from ideal behavior

    MOS CCDs for the wide field imager on the XEUS spacecraft

    Get PDF
    In recent years the XEUS mission concept has evolved and has been the subject of several industrial studies. The mission concept has now matured to the point that it could be proposed for a Phase A study and subsequent flight programme. The key feature of XEUS will be its X-ray optic with collecting area ~30-100x that of XMM. The mission is envisaged at an orbit around the L2 point in space, and is formed from two spacecraft; one for the mirrors, and the other for the focal plane detectors. With a focal length of 50m, the plate scale of the optic is 6.5x that of XMM, which using existing focal plane technology will reduce the effective field of view to a few arc minutes. Cryogenic instrumentation, with detector sizes of a few mm can only be used for narrow field studies of target objects, and a wide field instrument is under consideration using a DEPFET pixel array to image out to a diameter of 5 arcminutes, requiring an array of dimension 70mm. It is envisaged to extend this field of view possibly out to 15 arcminutes through the use of an outer detection ring comprised of MOS CCD

    Pathological features and outcomes of incidental renal cell carcinoma in candidate solid organ donors

    Get PDF
    Background: We report the findings of a single Italian center in the evaluation of renal lesions in deceased donors from 2001 to 2017. In risk evaluation, we applied the current Italian guidelines, which include donors with small (< 4 cm, stage pT1a) renal carcinomas in the category of non-standard donors with a negligible risk of cancer transmission. Methods: From the revision of our registries, 2,406 donors were considered in the Emilia Romagna region of Italy; organs were accepted from 1,321 individuals for a total of 3,406 organs. Results: The evaluation of donor safety required frozen section analysis for 51 donors, in which a renal suspicious lesion was detected by ultrasound. Thirty-two primary renal tumors were finally diagnosed: 26 identified by frozen sections and 6 in discarded kidneys. The 32 tumors included 13 clear cell renal cell carcinomas (RCCs), 6 papillary RCCs, 6 angiomyolipomas, 5 oncocytomas, 1 chromophobe RCC, and 1 papillary adenoma. No cases of tumor transmission were recorded in follow-up of the recipients. Conclusion: Donors with small RCCs can be accepted to increase the donor pool. Collaboration in a multidisciplinary setting is fundamental to accurately evaluate donor candidate risk assessment and to improve standardized protocols for surgeons and pathologists

    Measurements and tests on FBK silicon sensors with an optimized electronic design for a CTA camera

    Full text link
    In October 2013, the Italian Ministry approved the funding of a Research & Development (R&D) study, within the "Progetto Premiale TElescopi CHErenkov made in Italy (TECHE)", devoted to the development of a demonstrator for a camera for the Cherenkov Telescope Array (CTA) consortium. The demonstrator consists of a sensor plane based on the Silicon Photomultiplier (SiPM) technology and on an electronics designed for signal sampling. Preliminary tests on a matrix of sensors produced by the Fondazione Bruno Kessler (FBK-Trento, Italy) and on electronic prototypes produced by SITAEL S.p.A. will be presented. In particular, we used different designs of the electronics in order to optimize the output signals in terms of tail cancellation. This is crucial for applications where a high background is expected, as for the CTA experiment.Comment: 5 pages, 6 figures; Proceedings of the 10th Workshop on Science with the New Generation of High-Energy Gamma-ray experiments (SciNeGHE) - PoS(Scineghe2014)00

    SiPM and front-end electronics development for Cherenkov light detection

    Full text link
    The Italian Institute of Nuclear Physics (INFN) is involved in the development of a demonstrator for a SiPM-based camera for the Cherenkov Telescope Array (CTA) experiment, with a pixel size of 6×\times6 mm2^2. The camera houses about two thousands electronics channels and is both light and compact. In this framework, a R&D program for the development of SiPMs suitable for Cherenkov light detection (so called NUV SiPMs) is ongoing. Different photosensors have been produced at Fondazione Bruno Kessler (FBK), with different micro-cell dimensions and fill factors, in different geometrical arrangements. At the same time, INFN is developing front-end electronics based on the waveform sampling technique optimized for the new NUV SiPM. Measurements on 1×\times1 mm2^2, 3×\times3 mm2^2, and 6×\times6 mm2^2 NUV SiPMs coupled to the front-end electronics are presentedComment: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.0589

    Penetrating particle ANalyzer (PAN)

    Full text link
    PAN is a scientific instrument suitable for deep space and interplanetary missions. It can precisely measure and monitor the flux, composition, and direction of highly penetrating particles (>> \sim100 MeV/nucleon) in deep space, over at least one full solar cycle (~11 years). The science program of PAN is multi- and cross-disciplinary, covering cosmic ray physics, solar physics, space weather and space travel. PAN will fill an observation gap of galactic cosmic rays in the GeV region, and provide precise information of the spectrum, composition and emission time of energetic particle originated from the Sun. The precise measurement and monitoring of the energetic particles is also a unique contribution to space weather studies. PAN will map the flux and composition of penetrating particles, which cannot be shielded effectively, precisely and continuously, providing valuable input for the assessment of the related health risk, and for the development of an adequate mitigation strategy. PAN has the potential to become a standard on-board instrument for deep space human travel. PAN is based on the proven detection principle of a magnetic spectrometer, but with novel layout and detection concept. It will adopt advanced particle detection technologies and industrial processes optimized for deep space application. The device will require limited mass (~20 kg) and power (~20 W) budget. Dipole magnet sectors built from high field permanent magnet Halbach arrays, instrumented in a modular fashion with high resolution silicon strip detectors, allow to reach an energy resolution better than 10\% for nuclei from H to Fe at 1 GeV/n

    Instability of two interacting, quasi-monochromatic waves in shallow water

    Full text link
    We study the nonlinear interactions of waves with a doubled-peaked power spectrum in shallow water. The starting point is the prototypical equation for nonlinear uni-directional waves in shallow water, i.e. the Korteweg de Vries equation. Using a multiple-scale technique two defocusing coupled Nonlinear Schr\"odinger equations are derived. We show analytically that plane wave solutions of such a system can be unstable to small perturbations. This surprising result suggests the existence of a new energy exchange mechanism which could influence the behaviour of ocean waves in shallow water.Comment: 4 pages, 2 figure

    The adherent/invasive escherichia coli (AIEC) strain LF82 invades and persists in human prostate cell lineRWPE-1 activating a strong inflammatory response

    Get PDF
    Adherent/invasive Escherichia coli (AIEC) strains have recently been receiving increased attention because they are more prevalent and persistent in the intestine of Crohn's disease (CD) patients than in healthy subjects. Since AIEC strains show a high percentage of similarity to extraintestinal pathogenic E. coli (ExPEC), neonatal meningitis-associated E. coli (NMEC), and uropathogenic E. coli (UPEC) strains, here we compared AIEC strain LF82 with a UPEC isolate (strain EC73) to assess whether LF82 would be able to infect prostate cells as an extraintestinal target. The virulence phenotypes of both strains were determined by using the RWPE-1 prostate cell line. The results obtained indicated that LF82 and EC73 are able to adhere to, invade, and survive within prostate epithelial cells. Invasion was confirmed by immunofluorescence and electron microscopy. Moreover, cytochalasin D and colchicine strongly inhibited bacterial uptake of both strains, indicating the involvement of actin microfilaments and microtubules in host cell invasion. Moreover, both strains belong to phylogenetic group B2 and are strong biofilm producers. In silico analysis reveals that LF82 shares with UPEC strains several virulence factors: namely, type 1 pili, the group II capsule, the vacuolating autotransporter toxin, four iron uptake systems, and the pathogenic island (PAI). Furthermore, compared to EC73, LF82 induces in RWPE-1 cells a marked increase of phosphorylation of mitogen-activated protein kinases (MAPKs) and of NF-κB already by 5 min postinfection, thus inducing a strong inflammatory response. Our in vitro data support the hypothesis that AIEC strains might play a role in prostatitis, and, by exploiting host-cell signaling pathways controlling the innate immune response, likely facilitate bacterial multiplication and dissemination within the male genitourinary trac

    miRNA Signatures in Sera of Patients with Active Pulmonary Tuberculosis.

    Get PDF
    Several studies showed that assessing levels of specific circulating microRNAs (miRNAs) is a non-invasive, rapid, and accurate method for diagnosing diseases or detecting alterations in physiological conditions. We aimed to identify a serum miRNA signature to be used for the diagnosis of tuberculosis (TB). To account for variations due to the genetic makeup, we enrolled adults from two study settings in Europe and Africa. The following categories of subjects were considered: healthy (H), active pulmonary TB (PTB), active pulmonary TB, HIV co-infected (PTB/HIV), latent TB infection (LTBI), other pulmonary infections (OPI), and active extra-pulmonary TB (EPTB). Sera from 10 subjects of the same category were pooled and, after total RNA extraction, screened for miRNA levels by TaqMan low-density arrays. After identification of "relevant miRNAs", we refined the serum miRNA signature discriminating between H and PTB on individual subjects. Signatures were analyzed for their diagnostic performances using a multivariate logistic model and a Relevance Vector Machine (RVM) model. A leave-one-out-cross-validation (LOOCV) approach was adopted for assessing how both models could perform in practice. The analysis on pooled specimens identified selected miRNAs as discriminatory for the categories analyzed. On individual serum samples, we showed that 15 miRNAs serve as signature for H and PTB categories with a diagnostic accuracy of 82% (CI 70.2-90.0), and 77% (CI 64.2-85.9) in a RVM and a logistic classification model, respectively. Considering the different ethnicity, by selecting the specific signature for the European group (10 miRNAs) the diagnostic accuracy increased up to 83% (CI 68.1-92.1), and 81% (65.0-90.3), respectively. The African-specific signature (12 miRNAs) increased the diagnostic accuracy up to 95% (CI 76.4-99.1), and 100% (83.9-100.0), respectively. Serum miRNA signatures represent an interesting source of biomarkers for TB disease with the potential to discriminate between PTB and LTBI, but also among the other categories

    Management of bile duct injuries after cholecystectomy: Therapeutic approach and examination of possible sources of error. Report of 2 cases

    Get PDF
    Background: Bile duct injuries is the primary concern of general surgeons during and after cholecystectomy, with an incidence ranging from 0.08% to 0.4%. Through the description of two cases we intend to discuss the management of most frequent types of bile duct injuries after cholecystectomy and examine some possible sources of error. Case reports: We have treated 2 cases previously operated by other surgical teams. Case report 1: patient undergoing laparoscopic cholecystectomy with lesion of the main bile duct, treated with its reconstruction with positioning of a T-drainage tube. Case report 2: patient with jaundice previously treated for incarcerated incisional hernia and gallbladder stones. We verified the presence of a stenosis of the main bile duct which was resolved with the positioning of a T-tube drainage Discussion: Many descriptions and classifications regarding iatrogenic lesions of the bile duct after cholecystectomy have been described, although some of them represent a good guide on the surgical approach to be adopted, but the surgical skills possessed by the operator remain the most important variables Conclusions: All possible precautions must be considered in order to avoid the possibility of damaging the biliary tree. In our opinion an anterograde approach during cholecystectomy offers greater safety
    corecore