6 research outputs found

    Effectiveness, safety/tolerability of OBV/PTV/r ± DSV in patients with HCV genotype 1 or 4 with/without HIV-1 co-infection, chronic kidney disease (CKD) stage IIIb-V and dialysis in Spanish clinical practice - Vie-KinD study

    Get PDF
    Limited data are available on the effectiveness and tolerability of direct-acting antivirals (DAAs) therapies in the real world for HCV-infected patients with comorbidities. This study aimed to describe the effectiveness of OBV/PTV/r ± DSV (3D/2D regimen) with or without ribavirin (RBV) in HCV or HCV/HIV co-infected patients with GT1/GT4 and CKD (IIIb-V stages), including those under hemodialysis and peritoneal dialysis in routine clinical practice in Spain in 2015.Non-interventional, retrospective, multicenter data collection study in 31 Spanish sites. Socio-demographic, clinical variables, study treatment characteristics, effectiveness and tolerability data were collected from medical records.Data from 135 patients with a mean age (SD) of 58.3 (11.4) years were analyzed: 92.6% GT1 (81.6% GT1b and 17.6% GT1a) and 7.4% GT4, 14 (10.4%) HIV/HCV co-infected, 19.0% with fibrosis F3 and 28.1% F4 by FibroScanŸ, 52.6% were previously treated with pegIFN and RBV. 11.1%, 14.8% and 74.1% of patients had CKD stage IIIb, IV and V respectively. 68.9% of patients were on hemodialysis; 8.9% on peritoneal dialysis and 38.5% had history of renal transplant. A total of 125 (96.2%) of 135 patients were treated with 3D, 10 (7.4%) with 2D and 30.4% received RBV. The overall intention-to-treat (ITT) sustained virologic response at week 12 (SVR12) was 92.6% (125/135) and the overall modified-ITT (mITT) SVR12 was 99.2% (125/126). The SVR12 rates (ITT) per sub-groups were: HCV mono-infected (91.7%), HCV/HIV co-infected (100%), GT1 (92.0%), GT4 (100%), CKD stage IIIb (86.7%), stage IV (95%) and stage V (93%). Among the 10 non-SVR there was only 1 virologic failure (0.7%); 4 patients had missing data due lost to follow up (3.0%) and 5 patients discontinued 3D/2D regimen (3.7%): 4 due to severe adverse events (including 3 deaths) and 1 patientŽs decision.These results have shown that 3D/2D regimens are effective and tolerable in patients with advanced CKD including those in dialysis with GT 1 or 4 chronic HCV mono-infection and HIV/HCV coinfection in a real-life cohort. The overall SVR12 rates were 92.6% (ITT) and 99.2% (mITT) without clinically relevant changes in eGFR until 12 weeks post-treatment. These results are consistent with those reported in clinical trials

    Safety and Effectiveness Using 8 Weeks of Glecaprevir/Pibrentasvir in HCV-Infected Treatment-NaĂŻve Patients with Compensated Cirrhosis: The CREST Study

    No full text
    Introduction In clinical trials with hepatitis C virus-infected treatment-naive (TN) patients with compensated cirrhosis (CC), glecaprevir/pibrentasvir (G/P), a fixed-dose, once-daily, pangenotypic regimen, has demonstrated sustained virologic response at posttreatment Week 12 (SVR12) > 95%. We evaluated the real-world safety and effectiveness of 8-week G/P therapy in TN patients with CC, including certain subgroups of interest. Methods The CREST study is a real-world, noninterventional, multicenter study retrospectively assessing data from Canada, Germany, Israel, Italy, and Spain. The full analysis set (FAS) designated all patients in the study; the modified analysis set (MAS) excluded patients who discontinued G/P for nonvirologic failure or who had missing SVR12 data. The primary endpoint was SVR12; safety endpoints were also assessed. Results A total of 386 patients were included in the FAS, 375 patients completed the study, and 325 patients were included in the MAS; 51 patients had missing SVR12 data. Overall, in the MAS and FAS, SVR12 was achieved in 99.1% and 84.2% of patients, respectively. In subgroups of interest, the percentage of patients achieving SVR12 in the MAS (and FAS) was: genotype (GT)3: 97.5% (80.6%); FibroScan(R) >= 12.5 kPa: 98.9% (89.3%); platelet count < 100 x 10(9)/l: 100% (88.2%); both platelets < 150 x 10(9)/l and FibroScan(R) > 20 kPa: 100% (88.9%); aspartate aminotransferase-to-platelet ratio index > 1.09: 98.7% (83.1%); fibrosis-4 index > 3.25: 98.6% (84.0%); albumin < 3 g/dl: 100% (91.7%); people who use drugs: 97.7% (84.3%); psychiatric disorders: 96.6% (84.8%); and human immunodeficiency virus coinfection: 100% (95.0%). Overall, 26.9% (104/386) of patients experienced an adverse event, none of which were classed as serious. Conclusion In this real-world cohort, 8 weeks of G/P therapy was well tolerated in TN patients with CC. SVR12 rates were similar to clinical trials, supporting 8-week treatment in TN patients with CC, including those with signs of advanced liver disease and GT3 infection

    Una ventana abierta : diseño de la pagina web didåctica de la comunidad educativa del CPEE Parayas

    No full text
    El trabajo estĂĄ publicado en Internet. En el CD anexo se encuentra la web realizada. Resumen basado en ficha elaborada por los autoresEl trabajo se ha realizado en el aula de informĂĄtica del CPEE Parayas por 24 maestros de educaciĂłn especial pertenecientes al centro. Los objetivos son el desarrollo de la web del centro, la apertura al conocimiento de la comunidad educativa cĂĄntabra, el conocimiento de las herramientas de ediciĂłn web y el intercambio de experiencias educativas con otros centros. Para esto se ha desarrollado la web, definiendo primero su estructura bĂĄsica, dando a los profesores lecciones de html y repartiendo el trabajo en los distintos ciclos. La valoraciĂłn del equipo de trabajo sobre la actividad, es muy positiva, tanto para los alumnos, como para ellos mismos. Se han empleado diversos materiales de tipo informĂĄtico (software, cĂĄmara digital, etc.).ConsejerĂ­a de EducaciĂłn y Juventud de CantabriaCantabriaES

    ENGIU: Encuentro Nacional de Grupos de InvestigaciĂłn de UNIMINUTO.

    No full text
    El desarrollo del prototipo para el sistema de detección de Mina Antipersona (MAP), inicia desde el semillero ADSSOF perteneciente al programa de Administración en Seguridad y Salud en el trabajo de la UNIMINUTO, se realiza a partir de un detector de metales que emite una señal audible, que el usuario puede interpretar como aviso de presencia de un objeto metålico, en este caso una MAP. La señal audible se interpreta como un dato, como ese dato no es perceptible a 5 metros de distancia, se implementa el transmisor de Frecuencia Modulada FM por la facilidad de modulación y la escogencia de frecuencia de transmisión de acuerdo con las normas y resolución del Ministerio de Comunicaciones; de manera que esta sea la plataforma base para enviar los datos obtenidos a una frecuencia establecida. La idea es que el ser humano no explore zonas peligrosas y buscar la forma de crear un sistema que permita eliminar ese riesgo, por otro lado, buscar la facilidad de uso de elementos ya disponibles en el mercado

    Guidelines for the use and interpretation of assays for monitoring autophagy (4th edition)

    No full text
    In 2008, we published the first set of guidelines for standardizing research in autophagy. Since then, this topic has received increasing attention, and many scientists have entered the field. Our knowledge base and relevant new technologies have also been expanding. Thus, it is important to formulate on a regular basis updated guidelines for monitoring autophagy in different organisms. Despite numerous reviews, there continues to be confusion regarding acceptable methods to evaluate autophagy, especially in multicellular eukaryotes. Here, we present a set of guidelines for investigators to select and interpret methods to examine autophagy and related processes, and for reviewers to provide realistic and reasonable critiques of reports that are focused on these processes. These guidelines are not meant to be a dogmatic set of rules, because the appropriateness of any assay largely depends on the question being asked and the system being used. Moreover, no individual assay is perfect for every situation, calling for the use of multiple techniques to properly monitor autophagy in each experimental setting. Finally, several core components of the autophagy machinery have been implicated in distinct autophagic processes (canonical and noncanonical autophagy), implying that genetic approaches to block autophagy should rely on targeting two or more autophagy-related genes that ideally participate in distinct steps of the pathway. Along similar lines, because multiple proteins involved in autophagy also regulate other cellular pathways including apoptosis, not all of them can be used as a specific marker for bona fide autophagic responses. Here, we critically discuss current methods of assessing autophagy and the information they can, or cannot, provide. Our ultimate goal is to encourage intellectual and technical innovation in the field
    corecore